메뉴 건너뛰기




Volumn 22, Issue 10, 2007, Pages 3061-3064

How much is catheter flow influenced by the use of closed luer lock access devices?

Author keywords

Catheter; Connection; Flow resistance; Haemodialysis; Infection

Indexed keywords

ARTICLE; FLOW RATE; INTRAVENOUS CATHETER; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SIMULATION; VASCULAR RESISTANCE; WATER FLOW;

EID: 36049002522     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gfm314     Document Type: Article
Times cited : (12)

References (8)
  • 1
    • 0032822611 scopus 로고    scopus 로고
    • Haemodialysis catheter-related infection: Time for action
    • Canaud B. Haemodialysis catheter-related infection: time for action. Nephrol Dial Transplant 1999; 14: 2288-2290
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 2288-2290
    • Canaud, B.1
  • 2
    • 0030746333 scopus 로고    scopus 로고
    • Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis
    • Marr KA, Sexton DJ, Conlon PJ et al. Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis. Ann Intern Med 1997; 127: 275-280
    • (1997) Ann Intern Med , vol.127 , pp. 275-280
    • Marr, K.A.1    Sexton, D.J.2    Conlon, P.J.3
  • 3
    • 0031754864 scopus 로고    scopus 로고
    • Dialysis catheter-related septicaemia - focus on Staphylococcus aureus septicaemia
    • Nielsen J, Ladefoged SD, Kolmos HJJ. Dialysis catheter-related septicaemia - focus on Staphylococcus aureus septicaemia. Nephrol Dial Transplan 1998; 13: 2847-2852
    • (1998) Nephrol Dial Transplan , vol.13 , pp. 2847-2852
    • Nielsen, J.1    Ladefoged, S.D.2    Kolmos, H.J.J.3
  • 4
    • 0033050901 scopus 로고    scopus 로고
    • Septicemia in dialysis patients: Incidence, risk factors, and prognosis
    • Powe NR, Jaar B, Furth SL et al. Septicemia in dialysis patients: Incidence, risk factors, and prognosis. Kidney Intl 1999; 55: 1081-1090
    • (1999) Kidney Intl , vol.55 , pp. 1081-1090
    • Powe, N.R.1    Jaar, B.2    Furth, S.L.3
  • 5
    • 0142181296 scopus 로고    scopus 로고
    • A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: A prospective randomized study
    • Bouza E, Munoz P, Lopez-Rodriguez J et al. A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: a prospective randomized study. J Hosp Infect 2003; 54: 279-2876
    • (2003) J Hosp Infect , vol.54 , pp. 279-2876
    • Bouza, E.1    Munoz, P.2    Lopez-Rodriguez, J.3
  • 6
    • 0142150298 scopus 로고    scopus 로고
    • A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow((R)) needleless connector
    • Casey AL, Worthington T, Lambert PA et al. A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow((R)) needleless connector. J Hosp Infect 2003; 54: 288-293
    • (2003) J Hosp Infect , vol.54 , pp. 288-293
    • Casey, A.L.1    Worthington, T.2    Lambert, P.A.3
  • 7
    • 32044445516 scopus 로고    scopus 로고
    • Infection risk associated with a closed luer access device
    • Adams D, Karpanen T, Worthington T et al. Infection risk associated with a closed luer access device. J Hosp Infect 2006; 62: 353-357
    • (2006) J Hosp Infect , vol.62 , pp. 353-357
    • Adams, D.1    Karpanen, T.2    Worthington, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.