메뉴 건너뛰기




Volumn 345, Issue 1-2, 2007, Pages 108-115

Uniformity of poorly miscible powders determined by near infrared spectroscopy

Author keywords

Near infrared spectroscopy; Partial least squares modeling; Particle size; Powder mixing; Uniformity of powders

Indexed keywords

ALPHA LACTOSE; CARBAMAZEPINE;

EID: 36048996534     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijpharm.2007.05.044     Document Type: Article
Times cited : (12)

References (32)
  • 1
    • 0024701578 scopus 로고
    • Standard normal variate transformation and de-trending of near-infrared reflectance spectra
    • Barnes R.J., Dhanoa M.S., and Lister S.J. Standard normal variate transformation and de-trending of near-infrared reflectance spectra. Appl. Spectrosc. 43 (1989) 772-777
    • (1989) Appl. Spectrosc. , vol.43 , pp. 772-777
    • Barnes, R.J.1    Dhanoa, M.S.2    Lister, S.J.3
  • 2
    • 0015133119 scopus 로고
    • Dry powder aerosols. I. A new powder inhalation device
    • Bell J.H., Hartley P.S., and Cox J.S.G. Dry powder aerosols. I. A new powder inhalation device. J. Pharm. Sci. 60 (1971) 1559-1564
    • (1971) J. Pharm. Sci. , vol.60 , pp. 1559-1564
    • Bell, J.H.1    Hartley, P.S.2    Cox, J.S.G.3
  • 4
    • 0034663759 scopus 로고    scopus 로고
    • Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis
    • Berntsson O., Danielsson L.-G., Johansson M.O., and Folestad S. Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis. Anal. Chim. Acta 419 (2000) 45-54
    • (2000) Anal. Chim. Acta , vol.419 , pp. 45-54
    • Berntsson, O.1    Danielsson, L.-G.2    Johansson, M.O.3    Folestad, S.4
  • 5
    • 0037061158 scopus 로고    scopus 로고
    • Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy
    • Berntsson O., Danielsson L.-G., Lagerholm B., and Folestad S. Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy. Powder Technol. 123 (2002) 185-193
    • (2002) Powder Technol. , vol.123 , pp. 185-193
    • Berntsson, O.1    Danielsson, L.-G.2    Lagerholm, B.3    Folestad, S.4
  • 6
    • 4544354367 scopus 로고    scopus 로고
    • Strategies for constructing the calibration set for a near infrared spectroscopic quantitation method
    • Blanco M., Romero M.A., and Alcalà M. Strategies for constructing the calibration set for a near infrared spectroscopic quantitation method. Talanta 64 (2004) 597-602
    • (2004) Talanta , vol.64 , pp. 597-602
    • Blanco, M.1    Romero, M.A.2    Alcalà, M.3
  • 7
    • 0002295716 scopus 로고
    • Pharmaceutical mixing studies using near-infrared spectroscopy
    • Ciurczak E.W. Pharmaceutical mixing studies using near-infrared spectroscopy. Pharm. Technol. 15 (1991) 140-145
    • (1991) Pharm. Technol. , vol.15 , pp. 140-145
    • Ciurczak, E.W.1
  • 10
    • 27744509048 scopus 로고    scopus 로고
    • Process analytical technology case study. Part II. Development and validation of quantitative near-infrared calibrations in support of a process analytical technology application for real-time release
    • Cogdill R.P., Anderson C.A., Delgado M., Chisholm R., Bolton R., Herkert T., Afnan A.M., and Drennen III J.K. Process analytical technology case study. Part II. Development and validation of quantitative near-infrared calibrations in support of a process analytical technology application for real-time release. AAPS PharmSciTechnol. 6 (2005) E273-E283
    • (2005) AAPS PharmSciTechnol. , vol.6
    • Cogdill, R.P.1    Anderson, C.A.2    Delgado, M.3    Chisholm, R.4    Bolton, R.5    Herkert, T.6    Afnan, A.M.7    Drennen III, J.K.8
  • 11
    • 27744466385 scopus 로고    scopus 로고
    • Process analytical technology case study. Part III. Calibration monitoring and transfer
    • Cogdill R.P., Anderson C.A., and Drennen III J.K. Process analytical technology case study. Part III. Calibration monitoring and transfer. AAPS PharmSciTechnol. 6 (2005) E284-E297
    • (2005) AAPS PharmSciTechnol. , vol.6
    • Cogdill, R.P.1    Anderson, C.A.2    Drennen III, J.K.3
  • 12
    • 0034825280 scopus 로고    scopus 로고
    • Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity
    • El-Hagrasy A.S., Morris H.R., D'Amico F., Lodder R.A., and Drennen. Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity. J. Pharm. Sci. 90 (2001) 1298-1307
    • (2001) J. Pharm. Sci. , vol.90 , pp. 1298-1307
    • El-Hagrasy, A.S.1    Morris, H.R.2    D'Amico, F.3    Lodder, R.A.4    Drennen5
  • 14
    • 0000079353 scopus 로고    scopus 로고
    • Propagation of measurement errors for the validation of predictions obtained by principal component regression and partial least squares
    • Faber K., and Kowalski B.R. Propagation of measurement errors for the validation of predictions obtained by principal component regression and partial least squares. J. Chemometr. 11 (1997) 181-238
    • (1997) J. Chemometr. , vol.11 , pp. 181-238
    • Faber, K.1    Kowalski, B.R.2
  • 16
    • 36049024202 scopus 로고    scopus 로고
    • FDA (US Food and Drug Administration), 2004. Guidance for Industry: PAT-A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance. (http://www.fda.gov/cder/guidance/6419fnl.pdf, accessed March 22, 2007).
  • 18
    • 0033004851 scopus 로고    scopus 로고
    • The robust normal variate transform for pattern recognition with near-infrared data
    • Guo Q., Wu W., and Massart D.L. The robust normal variate transform for pattern recognition with near-infrared data. Anal. Chim. Acta 382 (1999) 87-103
    • (1999) Anal. Chim. Acta , vol.382 , pp. 87-103
    • Guo, Q.1    Wu, W.2    Massart, D.L.3
  • 19
    • 0016612648 scopus 로고
    • The effect of particle size upon mixture homogeneity
    • Johnson M.C.R. The effect of particle size upon mixture homogeneity. Pharm. Acta Helv. 50 (1975) 60-63
    • (1975) Pharm. Acta Helv. , vol.50 , pp. 60-63
    • Johnson, M.C.R.1
  • 20
    • 0000066915 scopus 로고
    • A fiber optics probe for investigating the internal structure of powder mixtures
    • Kaye B.H., Brushenko A., Ohlhaber R.L., and Pontarelli D.A. A fiber optics probe for investigating the internal structure of powder mixtures. Powder Technol. 2 (1969) 243-245
    • (1969) Powder Technol. , vol.2 , pp. 243-245
    • Kaye, B.H.1    Brushenko, A.2    Ohlhaber, R.L.3    Pontarelli, D.A.4
  • 21
    • 17644419597 scopus 로고    scopus 로고
    • Quantitation of active pharmaceutical ingredients and excipients in powder blends using designed multivariate calibration models by near-infrared spectroscopy
    • Li W., and Worosila G.D. Quantitation of active pharmaceutical ingredients and excipients in powder blends using designed multivariate calibration models by near-infrared spectroscopy. Int. J. Pharm. 295 (2005) 213-219
    • (2005) Int. J. Pharm. , vol.295 , pp. 213-219
    • Li, W.1    Worosila, G.D.2
  • 22
    • 33750469307 scopus 로고    scopus 로고
    • Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe
    • Li W., Johnson M.C., Bruce R., Ulrich S., Rasmussen H., and Worosila G.D. Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe. Int. J. Pharm. 326 (2006) 182-185
    • (2006) Int. J. Pharm. , vol.326 , pp. 182-185
    • Li, W.1    Johnson, M.C.2    Bruce, R.3    Ulrich, S.4    Rasmussen, H.5    Worosila, G.D.6
  • 24
    • 0003015092 scopus 로고
    • Optimization of mathematical treatments of raw near-infrared signal in the measurement of protein in hard red spring wheat. I. Influence of particle size
    • Norris K.H., and Williams P.C. Optimization of mathematical treatments of raw near-infrared signal in the measurement of protein in hard red spring wheat. I. Influence of particle size. Cereal Chem. 61 (1984) 158-165
    • (1984) Cereal Chem. , vol.61 , pp. 158-165
    • Norris, K.H.1    Williams, P.C.2
  • 25
    • 0034714865 scopus 로고    scopus 로고
    • Quantitative analysis of polymorphs in binary and multi-component powder mixtures by near-infrared reflectance spectroscopy
    • Patel A.D., Luner P.E., and Kemper M.S. Quantitative analysis of polymorphs in binary and multi-component powder mixtures by near-infrared reflectance spectroscopy. Int. J. Pharm. 206 (2000) 63-74
    • (2000) Int. J. Pharm. , vol.206 , pp. 63-74
    • Patel, A.D.1    Luner, P.E.2    Kemper, M.S.3
  • 26
    • 0026360726 scopus 로고
    • Powder mixing: some practical rules applied to agitated systems
    • Poux M., Fayolle P., and Bertrand J. Powder mixing: some practical rules applied to agitated systems. Powder Technol. 68 (1991) 213-234
    • (1991) Powder Technol. , vol.68 , pp. 213-234
    • Poux, M.1    Fayolle, P.2    Bertrand, J.3
  • 27
    • 22744449026 scopus 로고    scopus 로고
    • Improved understanding of factors contributing to quantification of anhydrate/hydrate powder mixtures
    • Rantanen J., Wikström H., Rhea F.E., and Taylor L.S. Improved understanding of factors contributing to quantification of anhydrate/hydrate powder mixtures. Appl. Spectrosc. 59 (2005) 942-951
    • (2005) Appl. Spectrosc. , vol.59 , pp. 942-951
    • Rantanen, J.1    Wikström, H.2    Rhea, F.E.3    Taylor, L.S.4
  • 30
    • 0031900167 scopus 로고    scopus 로고
    • Determination of the optimum mixing time for a mixture of lactose and colloidal silicon dioxide
    • Sindel U., Schweiger A., and Zimmermann I. Determination of the optimum mixing time for a mixture of lactose and colloidal silicon dioxide. J. Pharm. Sci. 87 (1998) 524-526
    • (1998) J. Pharm. Sci. , vol.87 , pp. 524-526
    • Sindel, U.1    Schweiger, A.2    Zimmermann, I.3
  • 31
    • 0013572420 scopus 로고
    • The mixing action of pharmaceutically used powder mixers
    • Speiser P., and Tawashi R. The mixing action of pharmaceutically used powder mixers. Pharm. Acta Helv. 37 (1962) 529-543
    • (1962) Pharm. Acta Helv. , vol.37 , pp. 529-543
    • Speiser, P.1    Tawashi, R.2
  • 32
    • 0030217890 scopus 로고    scopus 로고
    • Near-infrared spectroscopic characterization of pharmaceutical powder blends
    • Wargo D.J., and Drennen J.K. Near-infrared spectroscopic characterization of pharmaceutical powder blends. J. Pharm. Biomed. Anal. 14 (1996) 1415-1423
    • (1996) J. Pharm. Biomed. Anal. , vol.14 , pp. 1415-1423
    • Wargo, D.J.1    Drennen, J.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.