메뉴 건너뛰기




Volumn 19, Issue 11, 2007, Pages 464-468

Treatment of restenotic drug-eluting stents: An intravascular ultrasound analysis

Author keywords

[No Author keywords available]

Indexed keywords

PACLITAXEL; RAPAMYCIN;

EID: 35948997672     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (19)
  • 1
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 2
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 3
    • 0042388295 scopus 로고    scopus 로고
    • Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    • Colombo A, Drzewiecki J, Banning A, et al. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003;108:788-794.
    • (2003) Circulation , vol.108 , pp. 788-794
    • Colombo, A.1    Drzewiecki, J.2    Banning, A.3
  • 4
    • 9144249927 scopus 로고    scopus 로고
    • A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-231.
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3
  • 5
    • 2542445152 scopus 로고    scopus 로고
    • Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis from the sirius trial
    • Sonoda S, Morino Y, Ako J, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol 2004;43:1959-1963.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1959-1963
    • Sonoda, S.1    Morino, Y.2    Ako, J.3
  • 6
    • 18144424770 scopus 로고    scopus 로고
    • Intravascular ultra sound stent area of sirolimus-eluting stents and its impact on late outcome
    • Cheneau E, Pichard AD, Satler LF, et al. Intravascular ultra sound stent area of sirolimus-eluting stents and its impact on late outcome. Am J Cardiol 2005;95:1240-1242.
    • (2005) Am J Cardiol , vol.95 , pp. 1240-1242
    • Cheneau, E.1    Pichard, A.D.2    Satler, L.F.3
  • 7
    • 13844297890 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation
    • Takebayashi H, Kobayashi Y, Mintz GS, et al. Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation. Am J Cardiol 2005;95:498-502.
    • (2005) Am J Cardiol , vol.95 , pp. 498-502
    • Takebayashi, H.1    Kobayashi, Y.2    Mintz, G.S.3
  • 8
    • 33745697915 scopus 로고    scopus 로고
    • Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation
    • Hong MK, Mintz GS, Lee CW, et al. Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation. Eur Heart J 2006;27:1305-1310.
    • (2006) Eur Heart J , vol.27 , pp. 1305-1310
    • Hong, M.K.1    Mintz, G.S.2    Lee, C.W.3
  • 9
    • 20144388922 scopus 로고    scopus 로고
    • Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study
    • Fujii K, Carlier SG, Mintz GS, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study. J Am Coll Cardiol 2005;45:995-998.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 995-998
    • Fujii, K.1    Carlier, S.G.2    Mintz, G.S.3
  • 10
    • 2642575029 scopus 로고    scopus 로고
    • Post-sirolimus-eluting stent restenosis treated with repeat percutaneous intervention: Late angiographic and clinical outcomes
    • Lemos PA, van Mieghem CA, Arampatzis CA, et al. Post-sirolimus-eluting stent restenosis treated with repeat percutaneous intervention: Late angiographic and clinical outcomes. Circulation 2004;109:2500-2502.
    • (2004) Circulation , vol.109 , pp. 2500-2502
    • Lemos, P.A.1    van Mieghem, C.A.2    Arampatzis, C.A.3
  • 11
    • 33744978527 scopus 로고    scopus 로고
    • Drug-eluting stent restenosis the pattern predicts the outcome
    • Cosgrave J, Melzi G, Biondi-Zoccai GG, et al. Drug-eluting stent restenosis the pattern predicts the outcome. J Am Col Cardiol 2006;47:2399-2404.
    • (2006) J Am Col Cardiol , vol.47 , pp. 2399-2404
    • Cosgrave, J.1    Melzi, G.2    Biondi-Zoccai, G.G.3
  • 12
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz GS, Nissen SE, Anderson WD, et al. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-1492.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3
  • 13
    • 0030587303 scopus 로고    scopus 로고
    • Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis
    • Mehran R, Mintz GS, Popma JJ, et al. Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis. Am J Cardiol 1996;78:618-622.
    • (1996) Am J Cardiol , vol.78 , pp. 618-622
    • Mehran, R.1    Mintz, G.S.2    Popma, J.J.3
  • 14
    • 0028947782 scopus 로고
    • Serial intravascular ultrasound studies fail to show evidence of chronic Palmaz-Schatz stent recoil
    • Painter JA, Mintz GS, Wong SC, et al. Serial intravascular ultrasound studies fail to show evidence of chronic Palmaz-Schatz stent recoil. Am J Cardiol 1995;75:398-400.
    • (1995) Am J Cardiol , vol.75 , pp. 398-400
    • Painter, J.A.1    Mintz, G.S.2    Wong, S.C.3
  • 15
    • 0035091688 scopus 로고    scopus 로고
    • Treatment of focal in-stent restenosis with balloon angioplasty alone versus stenting: Short- and long-term results
    • Mehran R, Dangas G, Abizaid A, et al. Treatment of focal in-stent restenosis with balloon angioplasty alone versus stenting: Short- and long-term results. Am Heart J 2001;141:610-614.
    • (2001) Am Heart J , vol.141 , pp. 610-614
    • Mehran, R.1    Dangas, G.2    Abizaid, A.3
  • 16
    • 0041363363 scopus 로고    scopus 로고
    • A randomized comparison of repeat stenting with balloon angioplasty in patients with in-stent restenosis
    • Alfonso F, Zueco J, Cequier A, et al. A randomized comparison of repeat stenting with balloon angioplasty in patients with in-stent restenosis. J Am Coll Cardiol 2003;42:796-805.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 796-805
    • Alfonso, F.1    Zueco, J.2    Cequier, A.3
  • 17
    • 34347360228 scopus 로고    scopus 로고
    • Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis
    • Sano K, Mintz GS, Carlier SG, et al. Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis. Am J Cardiol 2006;98:1559-1562.
    • (2006) Am J Cardiol , vol.98 , pp. 1559-1562
    • Sano, K.1    Mintz, G.S.2    Carlier, S.G.3
  • 18
    • 0032499154 scopus 로고    scopus 로고
    • In-stent restenosis: The Washington Hospital Center experience
    • Mintz GS, Hoffmann R, Mehran R, et al. In-stent restenosis: The Washington Hospital Center experience. Am J Cardiol 1998;81:7E-13E.
    • (1998) Am J Cardiol , vol.81
    • Mintz, G.S.1    Hoffmann, R.2    Mehran, R.3
  • 19
    • 0032555105 scopus 로고    scopus 로고
    • Early lumen loss after treatment of instent restenosis: An intravascular ultrasound study
    • Shiran A, Mintz GS, Waksman R, et al. Early lumen loss after treatment of instent restenosis: An intravascular ultrasound study. Circulation 1998;98:200-203.
    • (1998) Circulation , vol.98 , pp. 200-203
    • Shiran, A.1    Mintz, G.S.2    Waksman, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.