메뉴 건너뛰기




Volumn 26, Issue 5, 2007, Pages 1315-1321

Patient safety concept for multichannel transmit coils

Author keywords

FDTD simulations; MR thermography; Multichannel transmit coils; RF safety; Specific absorption rate

Indexed keywords

AGAROSE;

EID: 35848949781     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21149     Document Type: Article
Times cited : (61)

References (28)
  • 1
    • 10744228692 scopus 로고    scopus 로고
    • Ultrahigh field magnetic resonance imaging and spectroscopy
    • Ugurbil K, Adriany G, Andersen P, et al. Ultrahigh field magnetic resonance imaging and spectroscopy. Magn Reson Imaging 2003; 21:1263-1281.
    • (2003) Magn Reson Imaging , vol.21 , pp. 1263-1281
    • Ugurbil, K.1    Adriany, G.2    Andersen, P.3
  • 2
    • 33845271477 scopus 로고    scopus 로고
    • 9.4 T human MRI: Preliminary results
    • Vaughan T, DelaBarre L, Snyder C, et al. 9.4 T human MRI: preliminary results. Magn Reson Med 2006;56:1274-1282.
    • (2006) Magn Reson Med , vol.56 , pp. 1274-1282
    • Vaughan, T.1    DelaBarre, L.2    Snyder, C.3
  • 3
    • 28444473098 scopus 로고    scopus 로고
    • B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
    • Van de Moortele PF, Akgun C, Adriany G, et al. B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil. Magn Reson Med 2005;54:1503-1518.
    • (2005) Magn Reson Med , vol.54 , pp. 1503-1518
    • Van de Moortele, P.F.1    Akgun, C.2    Adriany, G.3
  • 4
    • 31744439813 scopus 로고    scopus 로고
    • Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high magnetic resonance imaging
    • Truong TK, Chakeres DW, Beversdorf DQ, Scharre DW, Schmalbrock P. Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high magnetic resonance imaging. J Magn Reson Imaging 2006;24:103-112.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 103-112
    • Truong, T.K.1    Chakeres, D.W.2    Beversdorf, D.Q.3    Scharre, D.W.4    Schmalbrock, P.5
  • 5
    • 33749169500 scopus 로고    scopus 로고
    • Exploring the limits of RF shimming for high-field MRI of the human head
    • Mao W, Smith MB, Collins CM. Exploring the limits of RF shimming for high-field MRI of the human head. Magn Reson Med 2006;56: 918-922.
    • (2006) Magn Reson Med , vol.56 , pp. 918-922
    • Mao, W.1    Smith, M.B.2    Collins, C.M.3
  • 6
    • 33750630873 scopus 로고    scopus 로고
    • Parallel RF transmission with eight channels at 3 Tesla
    • Setsompop K, Wald LL, Alagappan V, et al. Parallel RF transmission with eight channels at 3 Tesla. Magn Reson Med 2006;56:1163-1171.
    • (2006) Magn Reson Med , vol.56 , pp. 1163-1171
    • Setsompop, K.1    Wald, L.L.2    Alagappan, V.3
  • 7
    • 1842586446 scopus 로고    scopus 로고
    • Parallel excitation with an array of transmit coils
    • Zhu YD. Parallel excitation with an array of transmit coils. Magn Reson Med 2004;51:775-784.
    • (2004) Magn Reson Med , vol.51 , pp. 775-784
    • Zhu, Y.D.1
  • 10
    • 35848944568 scopus 로고    scopus 로고
    • International Electrotechnical Commission (IEC). IEC 60601-2-33. Medical electrical equipment. Part 2-33: Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. IEC 60601-2-33 Ed. 2.1 b:2006. Geneva: IEC; 2006.
    • International Electrotechnical Commission (IEC). IEC 60601-2-33. Medical electrical equipment. Part 2-33: Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. IEC 60601-2-33 Ed. 2.1 b:2006. Geneva: IEC; 2006.
  • 11
    • 0036240672 scopus 로고    scopus 로고
    • Analysis of wave behavior in lossy dielectric samples at high field
    • Yang QX, Wang J, Zhang X, et al. Analysis of wave behavior in lossy dielectric samples at high field. Magn Reson Med 2002;47:982-989.
    • (2002) Magn Reson Med , vol.47 , pp. 982-989
    • Yang, Q.X.1    Wang, J.2    Zhang, X.3
  • 13
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calculations - a mathematical guide
    • Hoult, DI. The principle of reciprocity in signal strength calculations - a mathematical guide. Concepts Magn Reson 2000;12:173-187.
    • (2000) Concepts Magn Reson , vol.12 , pp. 173-187
    • Hoult, D.I.1
  • 14
    • 36849111386 scopus 로고
    • Proton resonance shift of water in the gas and liquid states
    • Hindman JC. Proton resonance shift of water in the gas and liquid states. J Chem Phys 1966;44:4582-4592.
    • (1966) J Chem Phys , vol.44 , pp. 4582-4592
    • Hindman, J.C.1
  • 16
    • 36249006213 scopus 로고    scopus 로고
    • Apparatus for the production of radio frequency B1 fields for NMR using current sheet antennas
    • US Patent US 7,049.818:2003
    • Seifert F, Rinneberg H, Junge S. Apparatus for the production of radio frequency B1 fields for NMR using current sheet antennas. US Patent US 7,049.818:2003.
    • Seifert, F.1    Rinneberg, H.2    Junge, S.3
  • 18
    • 0036740410 scopus 로고    scopus 로고
    • Performance and use of current sheet antennae for RF-hyperthermia of a phantom monitored by 3 Tesla MR-thermography
    • Hoffmann W, Rhein KH, Wojcik F, et al. Performance and use of current sheet antennae for RF-hyperthermia of a phantom monitored by 3 Tesla MR-thermography. Int J Hyperthermia 2002;18: 454-471.
    • (2002) Int J Hyperthermia , vol.18 , pp. 454-471
    • Hoffmann, W.1    Rhein, K.H.2    Wojcik, F.3
  • 19
    • 26844546900 scopus 로고    scopus 로고
    • Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels
    • Ullmann P, Junge S, Wick M, Seifert F, Ruhm W, Hennig J. Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Reson Med 2005;54:994-1001.
    • (2005) Magn Reson Med , vol.54 , pp. 994-1001
    • Ullmann, P.1    Junge, S.2    Wick, M.3    Seifert, F.4    Ruhm, W.5    Hennig, J.6
  • 20
    • 2442570617 scopus 로고    scopus 로고
    • Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
    • Collins CM, Liu W, Wang J, et al. Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz. J Magn Reson Imaging 2004;19:650-656.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 650-656
    • Collins, C.M.1    Liu, W.2    Wang, J.3
  • 22
    • 0035088714 scopus 로고    scopus 로고
    • Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • Christopher MC, Smith MB. Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 2001;45:692-699.
    • (2001) Magn Reson Med , vol.45 , pp. 692-699
    • Christopher, M.C.1    Smith, M.B.2
  • 23
    • 0032939464 scopus 로고    scopus 로고
    • Comparison of four magnetic resonance methods for mapping small temperature changes
    • Wlodarczyk W, Hentschel M, Wust P, et al. Comparison of four magnetic resonance methods for mapping small temperature changes. Phys Med Biol 1999;44:607-624.
    • (1999) Phys Med Biol , vol.44 , pp. 607-624
    • Wlodarczyk, W.1    Hentschel, M.2    Wust, P.3
  • 25
    • 33845263696 scopus 로고    scopus 로고
    • Fast 3D radiofrequency field mapping using echo-planar imaging
    • Jiru F, Klose U. Fast 3D radiofrequency field mapping using echo-planar imaging. Magn Reson Med 2006;56:1375-1379.
    • (2006) Magn Reson Med , vol.56 , pp. 1375-1379
    • Jiru, F.1    Klose, U.2
  • 27
    • 33750611311 scopus 로고    scopus 로고
    • Assessment of SAR values and coil performance for an adaptive 4-channel 3T proton head coil array
    • Kyoto, Japan, Abstract 665
    • Wuebbeler G, Seifert F, Junge S, Rinneberg H. Assessment of SAR values and coil performance for an adaptive 4-channel 3T proton head coil array. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004 (Abstract 665).
    • (2004) Proceedings of the 12th Annual Meeting of ISMRM
    • Wuebbeler, G.1    Seifert, F.2    Junge, S.3    Rinneberg, H.4
  • 28
    • 78650168039 scopus 로고    scopus 로고
    • Safety considerations concerning SAR during RF amplifier malfunctions in parallel transmission
    • Seattle, WA, USA, Abstract 2041
    • Graesslin I, Falaggis K, Vernickel P, et al. Safety considerations concerning SAR during RF amplifier malfunctions in parallel transmission. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, WA, USA, 2006 (Abstract 2041).
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM
    • Graesslin, I.1    Falaggis, K.2    Vernickel, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.