메뉴 건너뛰기




Volumn 52, Issue 6 SUPPL., 2007, Pages

What Do We Measure with Various Techniques When Assessing IOP?

Author keywords

deformation; dynamic contour tonometry; force; glaucoma; pressure; tonometry

Indexed keywords

ARTICLE; BLOOD FLOW; CORNEA; GLAUCOMA; HUMAN; INTRAOCULAR PRESSURE; MANOMETRY; MEASUREMENT; OPTIC NERVE; PHYSICS; PHYSIOLOGY; PRESSURE GRADIENT; PRIORITY JOURNAL; TONOMETER; TONOMETRY; TRABECULAR MESHWORK;

EID: 35848940063     PISSN: 00396257     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.survophthal.2007.08.003     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 35848950777 scopus 로고
    • Über ein verbessertes Tonometer
    • Dor H. Über ein verbessertes Tonometer. Klin Monatsbl Augenheilkd 3 (1865) 351
    • (1865) Klin Monatsbl Augenheilkd , vol.3 , pp. 351
    • Dor, H.1
  • 2
    • 0002790632 scopus 로고
    • Über Messung des Druckes im Auge
    • Fick A. Über Messung des Druckes im Auge. Pflügers Arch Ges Physiol 42 (1888) 86-90
    • (1888) Pflügers Arch Ges Physiol , vol.42 , pp. 86-90
    • Fick, A.1
  • 3
    • 70449195078 scopus 로고
    • Über Applanationstonometrie
    • Goldmann H., and Schmidt T. Über Applanationstonometrie. Ophthalmologica 134 (1957) 221-241
    • (1957) Ophthalmologica , vol.134 , pp. 221-241
    • Goldmann, H.1    Schmidt, T.2
  • 4
    • 0000893547 scopus 로고
    • Théorie des Ophtalmotonomètres
    • Imbert A. Théorie des Ophtalmotonomètres. Arch Ophtalmol Paris 5 (1885) 358-363
    • (1885) Arch Ophtalmol Paris , vol.5 , pp. 358-363
    • Imbert, A.1
  • 5
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: presentation of a new tonometer
    • Kanngiesser H.E., Kniestedt C., and Robert Y.C. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma 14 (2005) 344-350
    • (2005) J Glaucoma , vol.14 , pp. 344-350
    • Kanngiesser, H.E.1    Kniestedt, C.2    Robert, Y.C.3
  • 6
    • 33747203182 scopus 로고    scopus 로고
    • Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry
    • Kaufmann C., Bachmann L.M., Robert Y.C., et al. Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry. Arch Ophthalmol 124 (2006) 1104-1108
    • (2006) Arch Ophthalmol , vol.124 , pp. 1104-1108
    • Kaufmann, C.1    Bachmann, L.M.2    Robert, Y.C.3
  • 9
    • 0031780188 scopus 로고    scopus 로고
    • The correlation between cerebrospinal fluid pressure and retrolaminar tissue pressure
    • Morgan W.H., Yu D.Y., Alder V.A., et al. The correlation between cerebrospinal fluid pressure and retrolaminar tissue pressure. Invest Ophthalmol Vis Sci 39 (1998) 1419-1428
    • (1998) Invest Ophthalmol Vis Sci , vol.39 , pp. 1419-1428
    • Morgan, W.H.1    Yu, D.Y.2    Alder, V.A.3
  • 10
    • 0000677321 scopus 로고
    • Ein neuer tonometer: tonometrie
    • Schiøtz E. Ein neuer tonometer: tonometrie. Arch f Augenheilk 52 (1905) 401
    • (1905) Arch f Augenheilk , vol.52 , pp. 401
    • Schiøtz, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.