메뉴 건너뛰기




Volumn 65, Issue 2, 2007, Pages 225-233

Calibration of HPGe gamma-ray detectors for measurement of radioactive noble gas sources

Author keywords

Data analysis; Efficiency measurements; Gamma ray spectrometry; Gas spheres; Germanium detectors

Indexed keywords

CALIBRATION; DATA REDUCTION; GERMANIUM; INERT GASES; MATHEMATICAL TECHNIQUES; RADIATION DETECTORS;

EID: 35649024525     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2006.07.002     Document Type: Article
Times cited : (45)

References (12)
  • 1
    • 0035122507 scopus 로고    scopus 로고
    • HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions
    • Abbas M.I. HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions. Appl. Radiat. Isot. 54 (2001) 761
    • (2001) Appl. Radiat. Isot. , vol.54 , pp. 761
    • Abbas, M.I.1
  • 2
    • 37949057763 scopus 로고    scopus 로고
    • ANSI N42.14-1999. American National Standard for Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-ray Emission Rates of Radionuclides.
  • 3
    • 0017501745 scopus 로고
    • Calibration of Ge(Li) gamma-ray spectrometers for the measurement of radioactive noble gases
    • Coursey B.M., Hutchinson J.M.R., and Unterweger M.P. Calibration of Ge(Li) gamma-ray spectrometers for the measurement of radioactive noble gases. Int. J. Appl. Radiat. Isot. 28 (1977) 551-553
    • (1977) Int. J. Appl. Radiat. Isot. , vol.28 , pp. 551-553
    • Coursey, B.M.1    Hutchinson, J.M.R.2    Unterweger, M.P.3
  • 4
    • 37949023504 scopus 로고    scopus 로고
    • ENSDF Nuclear Data Sheets, 〈http://www.nndc.bnl.gov/ensdf/index.jsp〉, 〈http://www.nndc.bnl.gov/nudat2/indx_dec.jsp〉. IAEA Nuclear Data, 〈http://iaeand.iaea.or.at/〉. 〈http://www.nndc.bnl.gov/〉.
  • 5
    • 37949051983 scopus 로고    scopus 로고
    • Hamzawy, A., 2004. Accurate direct mathematical determination of the efficiencies of gamma detectors arising from radioactive sources of different shapes. Ph.D. Thesis. Alexandria University, Egypt.
  • 6
    • 37949005822 scopus 로고    scopus 로고
    • Hubbell, J. H., Seltzer, S. M., 1995. Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients 1 KeV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest. NISTIR 5632, USA.
  • 7
    • 37949050602 scopus 로고    scopus 로고
    • Mann, W.B., Schima, F.J., Unterweger, M.P., 1973. Radioactivity standards of the noble gases. In: noble gases symposium, 24-28 September, Las Vegas, Nevada, ERDA TIC as CONF-730915.
  • 9
    • 0019481834 scopus 로고
    • Absolute photopeak efficiency values for planar Ge-detectors in the gamma ray energy region 30-600 KeV with self-absorption in the source
    • Rieppo R. Absolute photopeak efficiency values for planar Ge-detectors in the gamma ray energy region 30-600 KeV with self-absorption in the source. Nucl. Instrum. Methods 179 (1981) 155-158
    • (1981) Nucl. Instrum. Methods , vol.179 , pp. 155-158
    • Rieppo, R.1
  • 10
    • 0037431729 scopus 로고    scopus 로고
    • Analysis of the influence of Ge dead layer on detector calibration simulation for environmental radioactive samples using the Monte Carlo method
    • Ródenaz J., Pascual A., Zarza I., Serradell V., Ortiz J., and Ballesteros L. Analysis of the influence of Ge dead layer on detector calibration simulation for environmental radioactive samples using the Monte Carlo method. Nucl. Instrum. Methods A 496 (2003) 390-399
    • (2003) Nucl. Instrum. Methods A , vol.496 , pp. 390-399
    • Ródenaz, J.1    Pascual, A.2    Zarza, I.3    Serradell, V.4    Ortiz, J.5    Ballesteros, L.6
  • 11
    • 0028470829 scopus 로고
    • Source-detector geometrical efficiency
    • Selim Y.S., and Abbas M.I. Source-detector geometrical efficiency. Radiat. Phys. Chem. 44 (1994) 1
    • (1994) Radiat. Phys. Chem. , vol.44 , pp. 1
    • Selim, Y.S.1    Abbas, M.I.2
  • 12
    • 0006092092 scopus 로고
    • Direct calculation of the total efficiency of cylindrical scintillation detectors for non-axial point sources
    • Selim Y.S., and Abbas M.I. Direct calculation of the total efficiency of cylindrical scintillation detectors for non-axial point sources. Egypt. J. Phys. 26 (1995) 79
    • (1995) Egypt. J. Phys. , vol.26 , pp. 79
    • Selim, Y.S.1    Abbas, M.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.