메뉴 건너뛰기




Volumn 23, Issue 11, 2007, Pages 1162-1166

A Biomechanical Analysis of a Novel Arthroscopic Suture Method Compared to Standard Suture Knots and Materials for Rotator Cuff Repair

Author keywords

Arthroscopic knot tying; Arthroscopic rotator cuff repair; Biomechanical stability; Cyclic testing; Loop security; Sonic weld suture technique

Indexed keywords

NYLON;

EID: 35649024129     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2007.06.011     Document Type: Article
Times cited : (6)

References (29)
  • 1
    • 19044374049 scopus 로고    scopus 로고
    • Open versus arthroscopic rotator cuff repair: A comparative view of 96 cases
    • Buess E., Steuber K.U., and Waibl B. Open versus arthroscopic rotator cuff repair: A comparative view of 96 cases. Arthroscopy 21 (2005) 597-604
    • (2005) Arthroscopy , vol.21 , pp. 597-604
    • Buess, E.1    Steuber, K.U.2    Waibl, B.3
  • 2
    • 20544465386 scopus 로고    scopus 로고
    • Arthroscopic treatment of anterior shoulder instability
    • Levine W.N., Rieger K., and McClusky III G.M. Arthroscopic treatment of anterior shoulder instability. Instr Course Lect 54 (2005) 87-96
    • (2005) Instr Course Lect , vol.54 , pp. 87-96
    • Levine, W.N.1    Rieger, K.2    McClusky III, G.M.3
  • 3
    • 14844301654 scopus 로고    scopus 로고
    • Arthroscopic versus mini-open rotator cuff repair: A cohort comparison study
    • Warner J.J., Tetreault P., Lehtinen J., and Zurakowski D. Arthroscopic versus mini-open rotator cuff repair: A cohort comparison study. Arthroscopy 21 (2005) 328-332
    • (2005) Arthroscopy , vol.21 , pp. 328-332
    • Warner, J.J.1    Tetreault, P.2    Lehtinen, J.3    Zurakowski, D.4
  • 4
    • 0042691524 scopus 로고    scopus 로고
    • Arthroscopic versus mini-open salvage repair of the rotator cuff tear: Outcome analysis at 2 to 6 years' follow up
    • Kim S.H., Ha K.I., Park J.H., Kang J.S., Oh S.K., and Oh I. Arthroscopic versus mini-open salvage repair of the rotator cuff tear: Outcome analysis at 2 to 6 years' follow up. Arthroscopy 19 (2003) 746-754
    • (2003) Arthroscopy , vol.19 , pp. 746-754
    • Kim, S.H.1    Ha, K.I.2    Park, J.H.3    Kang, J.S.4    Oh, S.K.5    Oh, I.6
  • 5
    • 0035497430 scopus 로고    scopus 로고
    • Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot
    • Kim S.H., Ha K.I., Kim S.H., and Kim J.S. Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot. Arthroscopy 17 (2001) 850-855
    • (2001) Arthroscopy , vol.17 , pp. 850-855
    • Kim, S.H.1    Ha, K.I.2    Kim, S.H.3    Kim, J.S.4
  • 8
    • 0036821894 scopus 로고    scopus 로고
    • Arthroscopic stabilization of anterior shoulder instability: A review of the literature
    • Stein D.A., Jazrawi L., and Bartolozzi A.R. Arthroscopic stabilization of anterior shoulder instability: A review of the literature. Arthroscopy 18 (2002) 912-924
    • (2002) Arthroscopy , vol.18 , pp. 912-924
    • Stein, D.A.1    Jazrawi, L.2    Bartolozzi, A.R.3
  • 9
    • 0032589174 scopus 로고    scopus 로고
    • Arthroscopic knot tying techniques
    • Nottage W.M., and Lieurnace R.K. Arthroscopic knot tying techniques. Arthroscopy 15 (1999) 515-521
    • (1999) Arthroscopy , vol.15 , pp. 515-521
    • Nottage, W.M.1    Lieurnace, R.K.2
  • 10
    • 0036767248 scopus 로고    scopus 로고
    • The double-twist knot: A new arthroscopic sliding knot
    • Rolla P.R., and Surace M.F. The double-twist knot: A new arthroscopic sliding knot. Arthroscopy 18 (2002) 815-820
    • (2002) Arthroscopy , vol.18 , pp. 815-820
    • Rolla, P.R.1    Surace, M.F.2
  • 12
    • 0031951417 scopus 로고    scopus 로고
    • Nicky's knot-A new slip knot for arthroscopic surgery
    • De Beer J.F., van Rooyen K., and Boezaart A.P. Nicky's knot-A new slip knot for arthroscopic surgery. Arthroscopy 14 (1998) 109-110
    • (1998) Arthroscopy , vol.14 , pp. 109-110
    • De Beer, J.F.1    van Rooyen, K.2    Boezaart, A.P.3
  • 13
    • 0032912570 scopus 로고    scopus 로고
    • The giant knot: A new one-way self-locking secured arthroscopic slip knot
    • Fleega B.A., and Sokkar S.H. The giant knot: A new one-way self-locking secured arthroscopic slip knot. Arthroscopy 15 (1999) 451-452
    • (1999) Arthroscopy , vol.15 , pp. 451-452
    • Fleega, B.A.1    Sokkar, S.H.2
  • 14
    • 30144435964 scopus 로고    scopus 로고
    • Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip
    • Abbi G., Espinosa L., Odell T., Mahar A., and Pedowitz R. Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip. Arthroscopy 22 (2006) 38-43
    • (2006) Arthroscopy , vol.22 , pp. 38-43
    • Abbi, G.1    Espinosa, L.2    Odell, T.3    Mahar, A.4    Pedowitz, R.5
  • 16
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: "Tension overload" as possible cause of failure
    • Burkhart S.S., Johnson T.A., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: "Tension overload" as possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.A.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 17
    • 33744524585 scopus 로고    scopus 로고
    • Comparison and performance characteristics of two suture materials for shoulder arthroscopy
    • Mahar A., Moezzi D., Serra-Hsu F., and Pedowitz R. Comparison and performance characteristics of two suture materials for shoulder arthroscopy. Arthroscopy 22 (2006) 614.e1-614.e2
    • (2006) Arthroscopy , vol.22
    • Mahar, A.1    Moezzi, D.2    Serra-Hsu, F.3    Pedowitz, R.4
  • 18
    • 0034235854 scopus 로고    scopus 로고
    • The SMC knot-A new slip knot with locking mechanism for loop security enhancement in the arthroscopic knot
    • Kim S.H., and Ha K.I. The SMC knot-A new slip knot with locking mechanism for loop security enhancement in the arthroscopic knot. Arthroscopy 16 (2000) 563-565
    • (2000) Arthroscopy , vol.16 , pp. 563-565
    • Kim, S.H.1    Ha, K.I.2
  • 19
    • 0038558408 scopus 로고    scopus 로고
    • The PC knot: A secure and satisfying arthroscopic slip knot
    • Pallia C.S. The PC knot: A secure and satisfying arthroscopic slip knot. Arthroscopy 19 (2003) 558-560
    • (2003) Arthroscopy , vol.19 , pp. 558-560
    • Pallia, C.S.1
  • 21
    • 13444263371 scopus 로고    scopus 로고
    • A biomechanical comparison of arthroscopic sliding and sliding-locking knots
    • Elkousy H.A., Sekiya J.K., Stabile K.J., and McMahon P.J. A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthroscopy 21 (2005) 204-210
    • (2005) Arthroscopy , vol.21 , pp. 204-210
    • Elkousy, H.A.1    Sekiya, J.K.2    Stabile, K.J.3    McMahon, P.J.4
  • 23
  • 24
    • 33748553043 scopus 로고    scopus 로고
    • Comparison of ultrasonic suture welding and traditional knot tying in a rabbit rotator cuff repair model
    • Nho S.J., Cole B.J., Mazzocca A.D., et al. Comparison of ultrasonic suture welding and traditional knot tying in a rabbit rotator cuff repair model. J Shoulder Elbow Surg 15 (2006) 630-638
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 630-638
    • Nho, S.J.1    Cole, B.J.2    Mazzocca, A.D.3
  • 25
    • 33748344692 scopus 로고    scopus 로고
    • Comparison of suture welding and hand-tied knots in mini-open rotator cuff repair
    • McIntyre L.F., Norris M., and Weber B. Comparison of suture welding and hand-tied knots in mini-open rotator cuff repair. Arthroscopy 22 (2006) 833-836
    • (2006) Arthroscopy , vol.22 , pp. 833-836
    • McIntyre, L.F.1    Norris, M.2    Weber, B.3
  • 26
    • 0031006780 scopus 로고    scopus 로고
    • A biomechanical evaluation of suture anchors in repair of the rotator cuff
    • Rossouw D.J., McElroy B.J., Amis A.A., and Emery R.J. A biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg 79-B (1997) 458-461
    • (1997) J Bone Joint Surg , vol.79 -B , pp. 458-461
    • Rossouw, D.J.1    McElroy, B.J.2    Amis, A.A.3    Emery, R.J.4
  • 27
    • 21444435692 scopus 로고    scopus 로고
    • Failure mode of suture anchors as a function of insertion depth
    • Bynum K., Lee S., Mahar A., Tasto J., and Pedowitz R. Failure mode of suture anchors as a function of insertion depth. Am J Sports Med 33 (2005) 1030-1034
    • (2005) Am J Sports Med , vol.33 , pp. 1030-1034
    • Bynum, K.1    Lee, S.2    Mahar, A.3    Tasto, J.4    Pedowitz, R.5
  • 28
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    • Burkhart S.S., Johnson T.C., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 29
    • 31844455176 scopus 로고    scopus 로고
    • A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair
    • Mahar A., Allred D.W., Wedemeyer M., Abbi G., and Pedowitz R. A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy 22 (2006) 130-135
    • (2006) Arthroscopy , vol.22 , pp. 130-135
    • Mahar, A.1    Allred, D.W.2    Wedemeyer, M.3    Abbi, G.4    Pedowitz, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.