메뉴 건너뛰기




Volumn 6532, Issue , 2007, Pages

Design of a multi-layered optical bend loss sensor for pressure and shear sensing

Author keywords

Bend loss sensor; Distributive mechanical sensor; Fiber optic sensor; Pressure sensor; Shear sensor

Indexed keywords

BEND LOSS SENSORS; DISTRIBUTIVE MECHANICAL SENSORS; SHEAR SENSORS;

EID: 35649010822     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.714720     Document Type: Conference Paper
Times cited : (8)

References (13)
  • 1
    • 0034648723 scopus 로고    scopus 로고
    • Foot ulcers
    • B.E. Sumpio, "Foot ulcers," New England J Med, Vol. 343, No. 11, p. 787-93, 2000.
    • (2000) New England J Med , vol.343 , Issue.11 , pp. 787-793
    • Sumpio, B.E.1
  • 2
    • 0025233640 scopus 로고
    • Pathways to diabetic limb amputation. Basis for prevention
    • R.E. Pecoraro, G.E. Reiber, and E.M. Burgess, "Pathways to diabetic limb amputation. Basis for prevention," Diabetes Care, Vol. 13, No. 5, p. 513-21, 1990.
    • (1990) Diabetes Care , vol.13 , Issue.5 , pp. 513-521
    • Pecoraro, R.E.1    Reiber, G.E.2    Burgess, E.M.3
  • 3
    • 0029127367 scopus 로고
    • Decreasing incidence of major amputation in diabetic patients: A consequence of a multidisciplinary foot care team approach?
    • J. Larsson, J. Apelqvist, C. Agardh, A. Stenstrom, "Decreasing incidence of major amputation in diabetic patients: A consequence of a multidisciplinary foot care team approach?" Diabetic Medicine, Vol. 12, No. 9, p. 770-6, 1995.
    • (1995) Diabetic Medicine , vol.12 , Issue.9 , pp. 770-776
    • Larsson, J.1    Apelqvist, J.2    Agardh, C.3    Stenstrom, A.4
  • 4
    • 0020661209 scopus 로고
    • Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy
    • A.J. Boulton, C.A. Hardisty, RP Betts, C.I. Franks, R.C. Worth, J.D. Ward and T. Duckworth, "Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy," Diabetes Care, Vol. 6, No. 1, p. 26-33, 1983.
    • (1983) Diabetes Care , vol.6 , Issue.1 , pp. 26-33
    • Boulton, A.J.1    Hardisty, C.A.2    Betts, R.P.3    Franks, C.I.4    Worth, R.C.5    Ward, J.D.6    Duckworth, T.7
  • 5
    • 0026717848 scopus 로고
    • The risk of foot ulceration in diabetic patients with high foot pressure: A prospective study
    • A. Veves, H.J. Murray, M.J. Young, A.J. Boulton, "The risk of foot ulceration in diabetic patients with high foot pressure: A prospective study," Diabetologia, Vol. 35, No. 7, p. 660-3, 1992.
    • (1992) Diabetologia , vol.35 , Issue.7 , pp. 660-663
    • Veves, A.1    Murray, H.J.2    Young, M.J.3    Boulton, A.J.4
  • 7
    • 0026539089 scopus 로고
    • Method for in-shoe shear stress measurement
    • Lord M, Hosein R, Williams RB, "Method for in-shoe shear stress measurement," J. Biomed. Eng., 1992, 14(3), PP181-186.
    • (1992) J. Biomed. Eng , vol.14 , Issue.3
    • Lord, M.1    Hosein, R.2    Williams, R.B.3
  • 8
    • 0030199242 scopus 로고    scopus 로고
    • In-shoe biaxial shear force measurement: The Kent shear system
    • Akhlaghi F, Pepper MG, "In-shoe biaxial shear force measurement: the Kent shear system", Med. Bio. Eng. Comput., 1996, 34(4), pp315-317.
    • (1996) Med. Bio. Eng. Comput , vol.34 , Issue.4 , pp. 315-317
    • Akhlaghi, F.1    Pepper, M.G.2
  • 9
    • 0032005095 scopus 로고    scopus 로고
    • A device for simultaneous measurement of pressure and shear force distribution on plantar surface of the foot
    • Davis BL, Perry JE, Neth DC, Waters KC, "A device for simultaneous measurement of pressure and shear force distribution on plantar surface of the foot", J. Application Biomech., 1998,14(1), pp93-104.
    • (1998) J. Application Biomech , vol.14 , Issue.1 , pp. 93-104
    • Davis, B.L.1    Perry, J.E.2    Neth, D.C.3    Waters, K.C.4
  • 10
    • 35648986971 scopus 로고    scopus 로고
    • Christ P, Gender M, Seitz P, A 3-D pressure distribution measuring platform with 8X8 sensors for simultaneous measurement of vertical and horizontal forces, VIEMED Scientific Meeting, Dinh B, editor. 1998 Aug 8-12, Brisbane (Australia): Proceedings of VIEMED Scientific Meeting, 1998, pp120-125.
    • Christ P, Gender M, Seitz P, "A 3-D pressure distribution measuring platform with 8X8 sensors for simultaneous measurement of vertical and horizontal forces", VIEMED Scientific Meeting, Dinh B, editor. 1998 Aug 8-12, Brisbane (Australia): Proceedings of VIEMED Scientific Meeting, 1998, pp120-125.
  • 11
    • 0033990751 scopus 로고    scopus 로고
    • A study of in-shoe plantar shear in normals
    • R. Hosein and M. Lord, "A study of in-shoe plantar shear in normals," Clinical Biomechanics, No. 15, p. 46-53, 2000.
    • (2000) Clinical Biomechanics , Issue.15 , pp. 46-53
    • Hosein, R.1    Lord, M.2
  • 12
    • 33749551894 scopus 로고    scopus 로고
    • A wireless composite optical bend loss sensor for pressure and shear measurement, Health Monitoring and Smart Nondestructive Evaluation of Structural and Biological Systems V
    • Chu-Yu Huang, Wen-Jong Wu, Shih-Chieh Fu, Per G. Reinhall, and Wei-Chih Wang, "A wireless composite optical bend loss sensor for pressure and shear measurement", Health Monitoring and Smart Nondestructive Evaluation of Structural and Biological Systems V, Proc. of SPIE Vol. 6177, 61770W, 2006
    • (2006) Proc. of SPIE , vol.6177
    • Huang, C.1    Wu, W.2    Fu, S.3    Reinhall, P.G.4    Wang, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.