메뉴 건너뛰기




Volumn 21, Issue 7-9, 2007, Pages 335-345

Evaluation of the multivariate selectivity of multi-way liquid chromatography methods

Author keywords

Diode array detection; Orthogonal liquid chromatography; PARAFAC; Two dimensional liquid chromatography

Indexed keywords

2D LIQUID CHROMATOGRAPHIES; DIODE ARRAY DETECTION; DRUG COMPOUNDS; MULTI DIMENSIONAL; MULTIVARIATE SELECTIVITY; ORTHOGONAL LIQUID CHROMATOGRAPHY; PARAFAC; PERFORMANCE; SELECTIVITY PARAMETERS; TWO-DIMENSIONAL LIQUID CHROMATOGRAPHY;

EID: 35649007965     PISSN: 08869383     EISSN: 1099128X     Source Type: Journal    
DOI: 10.1002/cem.1055     Document Type: Article
Times cited : (9)

References (38)
  • 3
    • 0025331978 scopus 로고
    • Automated instrumentation for comprehensive 2-dimensional high-performance Iiquid-chromatography of proteins
    • Bushey MM, Jorgenson JW. Automated instrumentation for comprehensive 2-dimensional high-performance Iiquid-chromatography of proteins. Anal. Chem. 1990; 62: 161-167.
    • (1990) Anal. Chem , vol.62 , pp. 161-167
    • Bushey, M.M.1    Jorgenson, J.W.2
  • 4
    • 2942622159 scopus 로고    scopus 로고
    • Comprehensive two-dimensional separations of complex mixtures using reversed-phase reversed-phase liquid chromatography
    • Gray MJ, Dennis GR, Slonecker PJ, Shalliker RA. Comprehensive two-dimensional separations of complex mixtures using reversed-phase reversed-phase liquid chromatography. J. Chromatogr. A 2004; 1041: 101-110.
    • (2004) J. Chromatogr. A , vol.1041 , pp. 101-110
    • Gray, M.J.1    Dennis, G.R.2    Slonecker, P.J.3    Shalliker, R.A.4
  • 5
    • 0032079807 scopus 로고    scopus 로고
    • Comprehensive two-dimensional high-performance liquid chromatography for the isolation of overexpressed proteins and proteome mapping
    • Opiteck GJ, Ramirez SM, Jorgenson JW, Moseley III. Comprehensive two-dimensional high-performance liquid chromatography for the isolation of overexpressed proteins and proteome mapping. Anal. Biochem. 1998; 258: 349-361.
    • (1998) Anal. Biochem , vol.258 , pp. 349-361
    • Opiteck, G.J.1    Ramirez, S.M.2    Jorgenson, J.W.3    Moseley III4
  • 6
    • 17144387482 scopus 로고    scopus 로고
    • Fast, comprehensive two-dimensional HPLC separation of tryptic peptides based on high-temperature HPLC
    • Stoll DR, Carr PW. Fast, comprehensive two-dimensional HPLC separation of tryptic peptides based on high-temperature HPLC. J. Am. Chem. Soc. 2005; 127: 5034-5035.
    • (2005) J. Am. Chem. Soc , vol.127 , pp. 5034-5035
    • Stoll, D.R.1    Carr, P.W.2
  • 7
    • 33745927416 scopus 로고    scopus 로고
    • Fast, comprehensive online two-dimensional high performance liquid chromatography through the use of high temperature ultra-fast gradient elution reversed-phase liquid chromatography
    • Stoll DR, Cohen JD, Carr PW. Fast, comprehensive online two-dimensional high performance liquid chromatography through the use of high temperature ultra-fast gradient elution reversed-phase liquid chromatography. J. Chromatogr. A 2006; 1122: 123-137.
    • (2006) J. Chromatogr. A , vol.1122 , pp. 123-137
    • Stoll, D.R.1    Cohen, J.D.2    Carr, P.W.3
  • 8
    • 24944485024 scopus 로고    scopus 로고
    • Proteomic analysis with integrated multiple dimensional liquid chromatography/mass spectrometry based on elution of ion exchange column using pH steps
    • Dai J, Shieh CH, Sheng QH, Zhou H, Zeng R. Proteomic analysis with integrated multiple dimensional liquid chromatography/mass spectrometry based on elution of ion exchange column using pH steps. Anal. Chem. 2005; 77: 5793-5799.
    • (2005) Anal. Chem , vol.77 , pp. 5793-5799
    • Dai, J.1    Shieh, C.H.2    Sheng, Q.H.3    Zhou, H.4    Zeng, R.5
  • 10
    • 32344434974 scopus 로고    scopus 로고
    • Comparison of two proteomics techniques used to identify proteins regulated by gibberellin in rice
    • Komatsu S, Zang X, Tanaka N. Comparison of two proteomics techniques used to identify proteins regulated by gibberellin in rice. J. Proteome Res. 2006; 5: 270-276.
    • (2006) J. Proteome Res , vol.5 , pp. 270-276
    • Komatsu, S.1    Zang, X.2    Tanaka, N.3
  • 11
  • 12
    • 0037469083 scopus 로고    scopus 로고
    • Recent developments in CANDECOMP/PARAFAC algorithms: A critical review
    • Faber NKM, Bro R, Hopke PK. Recent developments in CANDECOMP/PARAFAC algorithms: a critical review. Chemom. Intell. Lab. Syst. 2003; 65: 119-137.
    • (2003) Chemom. Intell. Lab. Syst , vol.65 , pp. 119-137
    • Faber, N.K.M.1    Bro, R.2    Hopke, P.K.3
  • 13
    • 0002740437 scopus 로고
    • Foundations of the PARAFAC procedure: Models and conditions for an 'explanatory' multi-modal factor analysis
    • Harshman RA. Foundations of the PARAFAC procedure: models and conditions for an 'explanatory' multi-modal factor analysis. UCLA Working Papers in Phonetics 1970; 16: 1-84.
    • (1970) UCLA Working Papers in Phonetics , vol.16 , pp. 1-84
    • Harshman, R.A.1
  • 14
    • 0001753960 scopus 로고    scopus 로고
    • Analytical figures of merit for tensorial calibration
    • Faber K, Lorber A, Kowalski BR. Analytical figures of merit for tensorial calibration. J. Chemom. 1997; 11: 419-461.
    • (1997) J. Chemom , vol.11 , pp. 419-461
    • Faber, K.1    Lorber, A.2    Kowalski, B.R.3
  • 15
    • 0000509143 scopus 로고    scopus 로고
    • Selectivity and related measures for nth order data
    • Messick NJ, Kalivas JH, Lang PM. Selectivity and related measures for nth order data. Anal. Chem. 1996; 68: 1572-1579.
    • (1996) Anal. Chem , vol.68 , pp. 1572-1579
    • Messick, N.J.1    Kalivas, J.H.2    Lang, P.M.3
  • 16
    • 23044491593 scopus 로고    scopus 로고
    • Computing sensitivity and selectivity in parallel factor analysis and related multiway techniques: The need for further developments in net analyte signal theory
    • Olivieri AC. Computing sensitivity and selectivity in parallel factor analysis and related multiway techniques: the need for further developments in net analyte signal theory. Anal. Chem. 2005; 77: 4936-4946.
    • (2005) Anal. Chem , vol.77 , pp. 4936-4946
    • Olivieri, A.C.1
  • 18
    • 0037470649 scopus 로고    scopus 로고
    • Net analyte signal as a deconvolution-oriented resolution criterion in the optimisation of chromatographic techniques
    • Vivo-Truyols G, Torres-Lapasio JR, Garcia-Alvarez-Coque MC. Net analyte signal as a deconvolution-oriented resolution criterion in the optimisation of chromatographic techniques. J. Chromatogr. A 2003; 991: 47-59.
    • (2003) J. Chromatogr. A , vol.991 , pp. 47-59
    • Vivo-Truyols, G.1    Torres-Lapasio, J.R.2    Garcia-Alvarez-Coque, M.C.3
  • 19
    • 33746837634 scopus 로고    scopus 로고
    • Analysis of four-way two-dimensional liquid chromatography-diode array data: Application to metabolomics
    • Porter SEG, Stoll DR, Rutan SC, Carr PW, Cohen JD. Analysis of four-way two-dimensional liquid chromatography-diode array data: application to metabolomics. Anal. Chem. 2006; 78: 5559-5569.
    • (2006) Anal. Chem , vol.78 , pp. 5559-5569
    • Porter, S.E.G.1    Stoll, D.R.2    Rutan, S.C.3    Carr, P.W.4    Cohen, J.D.5
  • 20
    • 0021508912 scopus 로고
    • Two-dimensional separations: Concept and premise
    • Giddings JC. Two-dimensional separations: concept and premise. Anal. Chem. 1984; 56: 1258A.
    • (1984) Anal. Chem , vol.56
    • Giddings, J.C.1
  • 21
    • 0030579579 scopus 로고    scopus 로고
    • Identification and quantification of overlapped peaks in liquid chromatography with UV diode array detection using an adaptive Kalman filter
    • Chen JC, Rutan SC. Identification and quantification of overlapped peaks in liquid chromatography with UV diode array detection using an adaptive Kalman filter. Anal.Chim. Acta 1996; 335: 1-10.
    • (1996) Anal.Chim. Acta , vol.335 , pp. 1-10
    • Chen, J.C.1    Rutan, S.C.2
  • 22
    • 0032076055 scopus 로고    scopus 로고
    • Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets
    • De Juan A, Rutan SC, Tauler R, Massart DL. Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets. Chemom. Intell. Lab. Syst. 1998; 40: 19-32.
    • (1998) Chemom. Intell. Lab. Syst , vol.40 , pp. 19-32
    • De Juan, A.1    Rutan, S.C.2    Tauler, R.3    Massart, D.L.4
  • 23
    • 0000640246 scopus 로고    scopus 로고
    • Three-way data analysis of pollutant degradation profiles monitored using liquid chromatography-diode array detection
    • Johnson K, De Juan A, Rutan SC. Three-way data analysis of pollutant degradation profiles monitored using liquid chromatography-diode array detection. J. Chemom. 1999; 13: 331-341.
    • (1999) J. Chemom , vol.13 , pp. 331-341
    • Johnson, K.1    De Juan, A.2    Rutan, S.C.3
  • 24
    • 0037008244 scopus 로고    scopus 로고
    • Comparison of methods for characterization of reversed-phase liquid chromatographic selectivity
    • Lopez LA, Rutan SC. Comparison of methods for characterization of reversed-phase liquid chromatographic selectivity. J. Chromatogr. A 2002; 965: 301-314.
    • (2002) J. Chromatogr. A , vol.965 , pp. 301-314
    • Lopez, L.A.1    Rutan, S.C.2
  • 26
    • 0033646780 scopus 로고    scopus 로고
    • Towards a standardized notation and terminology in multiway analysis
    • Kiers HAL. Towards a standardized notation and terminology in multiway analysis. J. Chemom. 2000; 14: 105-122.
    • (2000) J. Chemom , vol.14 , pp. 105-122
    • Kiers, H.A.L.1
  • 27
    • 0000404807 scopus 로고
    • Extension of trilinear decomposition method with an application to the flow probe sensor
    • Booksh KS, Lin ZH, Wang ZY, Kowalski BR. Extension of trilinear decomposition method with an application to the flow probe sensor. Anal. Chem. 1994; 66: 2561-2569.
    • (1994) Anal. Chem , vol.66 , pp. 2561-2569
    • Booksh, K.S.1    Lin, Z.H.2    Wang, Z.Y.3    Kowalski, B.R.4
  • 28
    • 0022723652 scopus 로고
    • Error propagation and figures of merit for quantification by solving matrix equations
    • Lorber A. Error propagation and figures of merit for quantification by solving matrix equations. Anal. Chem. 1986; 58: 1167-1172.
    • (1986) Anal. Chem , vol.58 , pp. 1167-1172
    • Lorber, A.1
  • 29
    • 0000479247 scopus 로고    scopus 로고
    • Net analyte signal calculation in multivariate calibration
    • Lorber A, Faber K, Kowalski BR. Net analyte signal calculation in multivariate calibration. Anal. Chem. 1997; 69: 1620-1626.
    • (1997) Anal. Chem , vol.69 , pp. 1620-1626
    • Lorber, A.1    Faber, K.2    Kowalski, B.R.3
  • 30
    • 85153543305 scopus 로고    scopus 로고
    • Olivieri AC, Faber K. A Closed-form expression for computing the sensitivity in second order bilinear calibration. J. Chemom. 2005; 19: 583-592.
    • Olivieri AC, Faber K. A Closed-form expression for computing the sensitivity in second order bilinear calibration. J. Chemom. 2005; 19: 583-592.
  • 31
    • 0001322212 scopus 로고
    • Improvement in the definitions of sensitivity and selectivity
    • Bergmann G, Vonoepen B, Zinn P. Improvement in the definitions of sensitivity and selectivity. Anal. Chem. 1987; 59: 2522-2526.
    • (1987) Anal. Chem , vol.59 , pp. 2522-2526
    • Bergmann, G.1    Vonoepen, B.2    Zinn, P.3
  • 32
    • 34547283747 scopus 로고    scopus 로고
    • Fast gradient elution reversed-phase high performance liquid chromatography with diode-array detection as a high throughput screening method for drugs of abuse: I. Chromatographic conditions
    • Stoll DR, Paek C, Carr PW. Fast gradient elution reversed-phase high performance liquid chromatography with diode-array detection as a high throughput screening method for drugs of abuse: I. Chromatographic conditions. J. Chromatogr. A 2006; 1137: 153-162.
    • (2006) J. Chromatogr. A , vol.1137 , pp. 153-162
    • Stoll, D.R.1    Paek, C.2    Carr, P.W.3
  • 33
    • 33745837479 scopus 로고    scopus 로고
    • Multiplexed two-dimensional liquid chromatography for MALDI and nanoelectrospray ionization mass spectrometry in proteomics
    • Saito H, Oda Y, Sato T, Kuromitsu J, Ishihama Y. Multiplexed two-dimensional liquid chromatography for MALDI and nanoelectrospray ionization mass spectrometry in proteomics. J. Proteome Res. 2006; 5: 1803-1807.
    • (2006) J. Proteome Res , vol.5 , pp. 1803-1807
    • Saito, H.1    Oda, Y.2    Sato, T.3    Kuromitsu, J.4    Ishihama, Y.5
  • 34
    • 30344443098 scopus 로고    scopus 로고
    • The application of 2-D dual nanoscale liquid chromatography and triple quadrupole-linear ion trap system for the identification of proteins
    • Tschappat V, Varesio E, Signor L, Hopfgartner G. The application of 2-D dual nanoscale liquid chromatography and triple quadrupole-linear ion trap system for the identification of proteins. J. Sepn. Sci. 2005; 28: 1704-1711.
    • (2005) J. Sepn. Sci , vol.28 , pp. 1704-1711
    • Tschappat, V.1    Varesio, E.2    Signor, L.3    Hopfgartner, G.4
  • 35
    • 33646740864 scopus 로고    scopus 로고
    • Peak capacity optimization of peptide separations in reversed-phase gradient elution chromatography: Fixed column format
    • Wang XL, Stoll DR, Schellinger AP, Carr PW. Peak capacity optimization of peptide separations in reversed-phase gradient elution chromatography: fixed column format. Anal. Chem. 2006; 78: 3406-3416.
    • (2006) Anal. Chem , vol.78 , pp. 3406-3416
    • Wang, X.L.1    Stoll, D.R.2    Schellinger, A.P.3    Carr, P.W.4
  • 36
    • 85153556254 scopus 로고    scopus 로고
    • Stoll DR, Wang X, Carr PW. A critical look at peak capacity production in 2D high performance liquid chromatography. Abstracts of papers of the American Chemical Society 232: 277-ANYL, 13 September 2006.
    • Stoll DR, Wang X, Carr PW. A critical look at peak capacity production in 2D high performance liquid chromatography. Abstracts of papers of the American Chemical Society 232: 277-ANYL, 13 September 2006.
  • 37
    • 12344259676 scopus 로고    scopus 로고
    • High speed gradient elution reversed-phase liquid chromatography
    • Schellinger AP, Stoll DR, Carr PW. High speed gradient elution reversed-phase liquid chromatography. J. Chromatogr. A 2005; 1064: 143-156.
    • (2005) J. Chromatogr. A , vol.1064 , pp. 143-156
    • Schellinger, A.P.1    Stoll, D.R.2    Carr, P.W.3
  • 38
    • 0001001925 scopus 로고    scopus 로고
    • Effect of sampling rate on resolution in comprehensive two-dimensional liquid chromatography
    • Murphy RE, Schure MR, Foley JP. Effect of sampling rate on resolution in comprehensive two-dimensional liquid chromatography. Anal. Chem. 1998; 70: 1585-1594.
    • (1998) Anal. Chem , vol.70 , pp. 1585-1594
    • Murphy, R.E.1    Schure, M.R.2    Foley, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.