메뉴 건너뛰기




Volumn 34, Issue 11, 2007, Pages 4098-4108

A rigidity penalty term for nonrigid registration

Author keywords

B splines; Mutual information; Nonrigid registration; Regularization; Rigidity penalty term

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DEFORMATION; INTERPOLATION; MEDICAL IMAGING; RIGIDITY;

EID: 35648999988     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2776236     Document Type: Article
Times cited : (137)

References (28)
  • 2
    • 0032785812 scopus 로고    scopus 로고
    • A survey of hierarchical non-linear medical image registration
    • H. Lester and S. R. Arridge, " A survey of hierarchical non-linear medical image registration., " Pattern Recogn. 32, 129-149 (1999).
    • (1999) Pattern Recogn. , vol.32 , pp. 129-149
    • Lester, H.1    Arridge, S.R.2
  • 3
    • 0032008619 scopus 로고    scopus 로고
    • A survey of medical image registration
    • J. B. A. Maintz and M. A. Viergever, " A survey of medical image registration., " Med. Image Anal 2, 1-36 (1998).
    • (1998) Med. Image Anal , vol.2 , pp. 1-36
    • Maintz, J.B.A.1    Viergever, M.A.2
  • 6
    • 23844468838 scopus 로고    scopus 로고
    • Nonrigid registration with adaptive, content-based filtering of the deformation field
    • M. Staring, S. Klein, and J. P. W. Pluim, " Nonrigid registration with adaptive, content-based filtering of the deformation field., " in "SPIE Medical Imaging: Image Processing," in Proc. SPIE Vol. 5747, 212-221.
    • Proc. SPIE , vol.5747 , pp. 212-221
    • Staring, M.1    Klein, S.2    Pluim, J.P.W.3
  • 7
    • 0042405180 scopus 로고    scopus 로고
    • Volume-preserving non-rigid registration of MR breast images using free-form deformation with an incompressibility constraint
    • T. Rohlfing, C. R. Maurer, Jr., D. A. Bluemke, and M. A. Jacobs, " Volume-preserving non-rigid registration of MR breast images using free-form deformation with an incompressibility constraint., " IEEE Trans. Med. Imaging 22, 730-741 (2003).
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 730-741
    • Rohlfing, T.1    Maurer Jr., C.R.2    Bluemke, D.A.3    Jacobs, M.A.4
  • 8
    • 84945566718 scopus 로고    scopus 로고
    • Volume and shape preservation of enhancing lesions when applying nonrigid registration to a time series of contrast enhancing MR breast images
    • Lecture Notes in Computer Science, Springer Verlag, Berlin/Heidelberg
    • C. Tanner, J. A. Schnabel, D. Chung, M. J. Clarkson, D. Rueckert, D. L. G. Hill, and D. J. Hawkes, " Volume and shape preservation of enhancing lesions when applying nonrigid registration to a time series of contrast enhancing MR breast images., " in MICCAI, Vol. 1935 Lecture Notes in Computer Science, 327-337 (Springer Verlag, Berlin/Heidelberg, 2000).
    • (2000) MICCAI , vol.1935 , pp. 327-337
    • Tanner, C.1    Schnabel, J.A.2    Chung, D.3    Clarkson, M.J.4    Rueckert, D.5    Hill, D.L.G.6    Hawkes, D.J.7
  • 9
    • 84958171130 scopus 로고    scopus 로고
    • Intensity-based nonrigid registration using adaptive multilevel free-form deformation with an incompressibility constraint
    • Lecture Notes in Computer Science, Springer Verlag, Berlin/Heidelberg
    • T. Rohlfing and C. R. Maurer, Jr., " Intensity-based nonrigid registration using adaptive multilevel free-form deformation with an incompressibility constraint., " in MICCAI, Vol. 2208 Lecture Notes in Computer Science, 111-119 (Springer Verlag, Berlin/Heidelberg, 2001).
    • (2001) MICCAI , vol.2208 , pp. 111-119
    • Rohlfing, T.1    Maurer Jr., C.R.2
  • 10
    • 0036624489 scopus 로고    scopus 로고
    • Automatic detection and segmentation of evolving processes in 3d medical images: Application to multiple sclerosis
    • D. Rey, G. Subsol, H. Delingette, and N. Ayache, " Automatic detection and segmentation of evolving processes in 3d medical images: Application to multiple sclerosis., " Med. Image Anal 6, 163-179 (2002).
    • (2002) Med. Image Anal , vol.6 , pp. 163-179
    • Rey, D.1    Subsol, G.2    Delingette, H.3    Ayache, N.4
  • 11
    • 33646397022 scopus 로고    scopus 로고
    • Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change
    • C. Studholme, C. S. Drapaca, B. Iordanova, and V. Cardenas, " Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change., " IEEE Trans. Med. Imaging 25, 626-639 (2006).
    • (2006) IEEE Trans. Med. Imaging , vol.25 , pp. 626-639
    • Studholme, C.1    Drapaca, C.S.2    Iordanova, B.3    Cardenas, V.4
  • 12
    • 0035205278 scopus 로고    scopus 로고
    • Why voxel-based morphometry should be used
    • J. Ashburner and K. J. Friston, " Why voxel-based morphometry should be used., " Neuroimage 14, 1238-1243 (2001).
    • (2001) Neuroimage , vol.14 , pp. 1238-1243
    • Ashburner, J.1    Friston, K.J.2
  • 13
    • 0035209053 scopus 로고    scopus 로고
    • Voxel-based morphometry should not be used with imperfectly registered images
    • F. L. Bookstein, " Voxel-based morphometry should not be used with imperfectly registered images., " Neuroimage 14, 1454-1462 (2001).
    • (2001) Neuroimage , vol.14 , pp. 1454-1462
    • Bookstein, F.L.1
  • 15
    • 1142288170 scopus 로고    scopus 로고
    • A unified approach to fast image registration and a new curvature based registration technique
    • B. Fischer and J. Modersitzki, " A unified approach to fast image registration and a new curvature based registration technique., " Linear Algebr. Appl. 380, 107-124 (2004).
    • (2004) Linear Algebr. Appl. , vol.380 , pp. 107-124
    • Fischer, B.1    Modersitzki, J.2
  • 16
    • 6344239178 scopus 로고    scopus 로고
    • Numerical methods for volume preserving image registration
    • E. Haber and J. Modersitzki, " Numerical methods for volume preserving image registration., " Inverse Probl. 20, 1621-1638 (2004).
    • (2004) Inverse Probl. , vol.20 , pp. 1621-1638
    • Haber, E.1    Modersitzki, J.2
  • 18
    • 27144539838 scopus 로고    scopus 로고
    • Polyrigid and polyaffine transformations: A novel geometrical tool to deal with non-rigid deformations application to the registration of histological slices
    • V. Arsigny, X. Pennec, and N. Ayache, " Polyrigid and polyaffine transformations: A novel geometrical tool to deal with non-rigid deformations application to the registration of histological slices., " Med. Image Anal 9, 507-523 (2005).
    • (2005) Med. Image Anal , vol.9 , pp. 507-523
    • Arsigny, V.1    Pennec, X.2    Ayache, N.3
  • 19
    • 20344365364 scopus 로고    scopus 로고
    • Nonrigid image registration using free-form deformations with a local rigidity constraint
    • Lecture Notes in Computer Science, Springer Verlag, Berlin/Heidelberg
    • D. Loeckx, F. Maes, D. Vandermeulen, and P. Suetens, " Nonrigid image registration using free-form deformations with a local rigidity constraint., " in MICCAI, Vol. 3216 Lecture Notes in Computer Science, 639-646 (Springer Verlag, Berlin/Heidelberg, 2004).
    • (2004) MICCAI , vol.3216 , pp. 639-646
    • Loeckx, D.1    Maes, F.2    Vandermeulen, D.3    Suetens, P.4
  • 20
    • 33745124391 scopus 로고    scopus 로고
    • Nonrigid registration using reglarization that accomodates local tissue rigidity
    • D. Ruan, J. A. Fessler, M. Roberson, J. Balter, and M. Kesler, " Nonrigid registration using reglarization that accomodates local tissue rigidity., " in SPIE Medical Imaging: Image Processing, in Proc. SPIE Vol. 6144, 346-354.
    • Proc. SPIE , vol.6144 , pp. 346-354
    • Ruan, D.1    Fessler, J.A.2    Roberson, M.3    Balter, J.4    Kesler, M.5
  • 21
    • 33745180210 scopus 로고    scopus 로고
    • Nonrigid registration using a rigidity constraint
    • M. Staring, S. Klein, and J. P. W. Pluim, " Nonrigid registration using a rigidity constraint., " in SPIE Medical Imaging: Image Processing, in Proc. SPIE Vol. 6144, 355-364.
    • Proc. SPIE , vol.6144 , pp. 355-364
    • Staring, M.1    Klein, S.2    Pluim, J.P.W.3
  • 22
    • 0000070850 scopus 로고    scopus 로고
    • Optimization of mutual information for multiresolution image registration
    • C. P. Th́venaz and M. Unser, " Optimization of mutual information for multiresolution image registration., " IEEE Trans. Image Process. 9, 2083-2099 (2000).
    • (2000) IEEE Trans. Image Process. , vol.9 , pp. 2083-2099
    • Th́venaz, C.P.1    Unser, M.2
  • 23
    • 23844456307 scopus 로고    scopus 로고
    • Comparison of gradient approximation techniques for optimisation of mutual information in nonrigid registration
    • S. Klein, M. Staring, and J. P. W. Pluim, " Comparison of gradient approximation techniques for optimisation of mutual information in nonrigid registration., " in SPIE Medical Imaging: Image Processing, in Proc. SPIE Vol. 5747 192-203.
    • Proc. SPIE , vol.5747 , pp. 192-203
    • Klein, S.1    Staring, M.2    Pluim, J.P.W.3
  • 24
    • 0032117046 scopus 로고    scopus 로고
    • Implementation of the simultaneous perturbation method for stochastic optimization
    • J. C. Spall, " Implementation of the simultaneous perturbation method for stochastic optimization., " IEEE Trans. Aerosp. Electron. Syst. 34, 817-823 (1998).
    • (1998) IEEE Trans. Aerosp. Electron. Syst. , vol.34 , pp. 817-823
    • Spall, J.C.1
  • 25
    • 0002999362 scopus 로고    scopus 로고
    • Splines: A perfect fit for signal and image processing
    • M. Unser, " Splines: A perfect fit for signal and image processing., " IEEE Signal Process. Mag. 16, 22-38 (1999).
    • (1999) IEEE Signal Process. Mag. , vol.16 , pp. 22-38
    • Unser, M.1
  • 27
    • 0035354205 scopus 로고    scopus 로고
    • Automatic lung segmentation for accurate quantitation of volumetric X-Ray CT images
    • S. Hu, E. A. Hoffman, and J. M. Reinhardt, " Automatic lung segmentation for accurate quantitation of volumetric X-Ray CT images., " IEEE Trans. Med. Imaging 20, 490-498 (2001).
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 490-498
    • Hu, S.1    Hoffman, E.A.2    Reinhardt, J.M.3
  • 28
    • 23844550632 scopus 로고    scopus 로고
    • Towards automated segmentation of the pathological lung in CT
    • I. C. Sluimer, M. Prokop, and B. van Ginneken, " Towards automated segmentation of the pathological lung in CT., " IEEE Trans. Med. Imaging 24, 1025-1038 (2005).
    • (2005) IEEE Trans. Med. Imaging , vol.24 , pp. 1025-1038
    • Sluimer, I.C.1    Prokop, M.2    Van Ginneken, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.