메뉴 건너뛰기




Volumn 16, Issue SUPPL. 2, 2007, Pages

Current opinions and recommendations on multimodal intraoperative monitoring during spine surgeries

Author keywords

Evoked potential; Guidelines; Intraoperative monitoring; Spine surgery

Indexed keywords

ANESTHETIC AGENT; KETAMINE; NITROUS OXIDE; PROPOFOL; REMIFENTANIL; ROCURONIUM; SEVOFLURANE;

EID: 35648989539     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-007-0421-z     Document Type: Conference Paper
Times cited : (81)

References (36)
  • 1
    • 0028186545 scopus 로고
    • Guideline eleven: Guidelines for intraoperative monitoring of sensory evoked potentials
    • American Electroencephalographic Society.
    • (1994) Guideline eleven: guidelines for intraoperative monitoring of sensory evoked potentials. American Electroencephalographic Society. J Clin Neurophysiol 11(1):77-87
    • (1994) J Clin Neurophysiol , vol.11 , Issue.1 , pp. 77-87
  • 6
    • 0036280895 scopus 로고    scopus 로고
    • Spinal cord monitoring
    • Cronin AJ (2002) Spinal cord monitoring. Curr Opin Orthop 13:188-192
    • (2002) Curr Opin Orthop , vol.13 , pp. 188-192
    • Cronin, A.J.1
  • 7
    • 1242265756 scopus 로고    scopus 로고
    • Intraoperative neurophysiology and methodologies used to monitor the functional integrity of the motor system
    • Academic California
    • Deletis V (2002) Intraoperative neurophysiology and methodologies used to monitor the functional integrity of the motor system. In: Deletis V, Shils JL (eds) Neurophysiology in Neurosurgery. Academic, California, pp 25-51
    • (2002) Neurophysiology in Neurosurgery , pp. 25-51
    • Deletis, V.1    Deletis2
  • 8
    • 0034943058 scopus 로고    scopus 로고
    • The role of intraoperative neurophysiology in the protection or documentation of surgically induced injury to the spinal cord
    • Deletis V, Sala F (2001) The role of intraoperative neurophysiology in the protection or documentation of surgically induced injury to the spinal cord. Ann NY Acad Sci 939:137-144
    • (2001) Ann NY Acad Sci , vol.939 , pp. 137-144
    • Deletis, V.1    Sala, F.2
  • 9
    • 2442585711 scopus 로고    scopus 로고
    • Intraoperative neurophysiological monitoring during spine surgery: An update
    • Deletis V, Sala F (2004) Intraoperative neurophysiological monitoring during spine surgery: an update. Curr Opin Orthop 15:154-158
    • (2004) Curr Opin Orthop , vol.15 , pp. 154-158
    • Deletis, V.1    Sala, F.2
  • 12
    • 35648965224 scopus 로고    scopus 로고
    • Multimodal intraoperative monitoring (MIOM) during surgical decompression of thoracic spinal stenosis in 36 patients
    • Eggspühler A, Sutter M, Grob D, Porchet F, Jeszenszky D, Dvorak J (2007) Multimodal intraoperative monitoring (MIOM) during surgical decompression of thoracic spinal stenosis in 36 patients. Eur Spine J (suppl.)
    • (2007) Eur Spine J (suppl.)
    • Eggspühler, A.1    Sutter, M.2    Grob, D.3    Porchet, F.4    Jeszenszky, D.5    Dvorak, J.6
  • 15
    • 0012868976 scopus 로고
    • Spinal cord action potentials evoked by epidural stimulation of the spinal cord - A report of human and animal record
    • Kurokawa T (1972) Spinal cord action potentials evoked by epidural stimulation of the spinal cord - a report of human and animal record. Jpn J Electroenceph Electromyogr 1:64-66
    • (1972) Jpn J Electroenceph Electromyogr , vol.1 , pp. 64-66
    • Kurokawa, T.1
  • 16
    • 31444435803 scopus 로고    scopus 로고
    • Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring
    • American Society of Neurophysiological M
    • Leppanen RE, Abnm D, American Society of Neurophysiological M (2005) Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput 19(6):437-461
    • (2005) J Clin Monit Comput , vol.19 , Issue.6 , pp. 437-461
    • Leppanen, R.E.1    Abnm, D.2
  • 17
    • 0035881440 scopus 로고    scopus 로고
    • Evaluation of various evoked potential techniques for spinal cord monitoring during scoliosis surgery
    • 16
    • Luk KD, Hu Y, Wong YW, Cheung KM (2001) Evaluation of various evoked potential techniques for spinal cord monitoring during scoliosis surgery. Spine 26(16):1772-1777
    • (2001) Spine , vol.26 , pp. 1772-1777
    • Luk, K.D.1    Hu, Y.2    Wong, Y.W.3    Cheung, K.M.4
  • 18
    • 33750076823 scopus 로고    scopus 로고
    • Intraoperative motor evoked potential monitoring: Overview and update
    • 5
    • Macdonald DB (2006) Intraoperative motor evoked potential monitoring: overview and update. J Clin Monit Comput 20(5):347-377
    • (2006) J Clin Monit Comput , vol.20 , pp. 347-377
    • MacDonald, D.B.1
  • 19
    • 35648979516 scopus 로고    scopus 로고
    • Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: Results in 206 thoraculumbar spine surgeries
    • Macdonald DB, Al Zayed Z (2007) Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoraculumbar spine surgeries. Eur Spine J (suppl.)
    • (2007) Eur Spine J (suppl.)
    • Macdonald, D.B.1    Al Zayed, Z.2
  • 21
    • 0142119953 scopus 로고
    • A model for electrical monitoring of spinal cord function in scoliosis patients undergoing correction
    • Nash CL, Brodkey JS, Croft TJ (1972) A model for electrical monitoring of spinal cord function in scoliosis patients undergoing correction. J Bone Joint Surg Am 54A:197-198
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 197-198
    • Nash, C.L.1    Brodkey, J.S.2    Croft, T.J.3
  • 22
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey
    • 1
    • Nuwer MR, Dawson EG, Carlson LG, Kanim LE, Sherman JE (1995) Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 96(1):6-11
    • (1995) Electroencephalogr Clin Neurophysiol , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, L.G.3    Kanim, L.E.4    Sherman, J.E.5
  • 24
    • 0033572524 scopus 로고    scopus 로고
    • The application of intraoperative monitoring during surgery for spinal deformity
    • 24
    • Owen JH (1999) The application of intraoperative monitoring during surgery for spinal deformity. Spine 24(24):2649-2662
    • (1999) Spine , vol.24 , pp. 2649-2662
    • Owen, J.H.1
  • 25
    • 35648962935 scopus 로고    scopus 로고
    • Surgery for intramedullary spinal cord tumors: The role of intraoperative neurophysiological monitoring
    • Sala F, Faccioli F, Lanteri P, Gerosa M (2007) Surgery for intramedullary spinal cord tumors: the role of intraoperative neurophysiological monitoring. Eur Spine J (suppl.)
    • (2007) Eur Spine J (suppl.)
    • Sala, F.1    Faccioli, F.2    Lanteri, P.3    Gerosa, M.4
  • 26
    • 0036664005 scopus 로고    scopus 로고
    • Intraoperative neurophysiological monitoring in pediatric neurosurgery: Why, when, how?
    • 6-7
    • Sala F, Krzan MJ, Deletis V (2002) Intraoperative neurophysiological monitoring in pediatric neurosurgery: why, when, how? Childs Nerv Syst 18(6-7):264-287
    • (2002) Childs Nerv Syst , vol.18 , pp. 264-287
    • Sala, F.1    Krzan, M.J.2    Deletis, V.3
  • 27
    • 33745085168 scopus 로고    scopus 로고
    • Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: A historical control study
    • 6. discussion 1129-1143
    • Sala F, Palandri G, Basso E, Lanteri P, Deletis V, Faccioli F, Bricolo A (2006) Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: a historical control study. Neurosurgery 58(6):1129-1143; discussion 1129-1143
    • (2006) Neurosurgery , vol.58 , pp. 1129-1143
    • Sala, F.1    Palandri, G.2    Basso, E.3    Lanteri, P.4    Deletis, V.5    Faccioli, F.6    Bricolo, A.7
  • 31
    • 35649017179 scopus 로고    scopus 로고
    • Multimodal intraoperative monitoring: An overview of proposed methodology based on 1017 cases
    • Sutter M, Eggspühler A, Muller A, Dvorak J (2007) Multimodal intraoperative monitoring: an overview of proposed methodology based on 1017 cases. Eur Spine J (suppl.)
    • (2007) Eur Spine J (suppl.)
    • Sutter, M.1    Eggspühler, A.2    Muller, A.3    Dvorak, J.4
  • 32
    • 35648952878 scopus 로고    scopus 로고
    • History and development of intraoperative monitoring during spine surgery
    • Tamaki T (2007) History and development of intraoperative monitoring during spine surgery. Eur Spine J
    • (2007) Eur Spine J
    • Tamaki, T.1
  • 34
    • 27744537004 scopus 로고    scopus 로고
    • Intraoperative monitoring using somatosensory evoked potentials. a position statement by the American Society of Neurophysiological Monitoring
    • 3
    • Toleikis JR (2005) Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput 19(3):241-258
    • (2005) J Clin Monit Comput , vol.19 , pp. 241-258
    • Toleikis, J.R.1
  • 35
    • 0027144474 scopus 로고
    • The use of dermatomal evoked responses during surgical procedures that use intrapedicular fixation of the lumbosacral spine
    • 16
    • Toleikis JR, Carlvin AO, Shapiro DE, Schafer MF (1993) The use of dermatomal evoked responses during surgical procedures that use intrapedicular fixation of the lumbosacral spine. Spine 18(16):2401-2407
    • (1993) Spine , vol.18 , pp. 2401-2407
    • Toleikis, J.R.1    Carlvin, A.O.2    Shapiro, D.E.3    Schafer, M.F.4
  • 36
    • 33747340260 scopus 로고    scopus 로고
    • Monitoring of scoliosis surgery with epidurally recorded motor evoked potentials (D wave) revealed false results
    • 9
    • Ulkatan S, Neuwirth M, Bitan F, Minardi C, Kokoszka A, Deletis V (2006) Monitoring of scoliosis surgery with epidurally recorded motor evoked potentials (D wave) revealed false results. Clin Neurophysiol 117(9):2093-2101
    • (2006) Clin Neurophysiol , vol.117 , pp. 2093-2101
    • Ulkatan, S.1    Neuwirth, M.2    Bitan, F.3    Minardi, C.4    Kokoszka, A.5    Deletis, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.