Volumn 6, Issue 4, 2007, Pages 238-245

Initial comparison of inverse optimization, modified peripheral technique, and geometric optimization as real-time intraoperative computer planning options for permanent seed implantation of the prostate

Author keywords

Intraoperative; Prostate; Seed implant

Indexed keywords

IODINE 125;

EID: 35648943632     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2007.08.001     Document Type: Article
Times cited : (8)

References (17)
  • 1
    • 0033625170 scopus 로고    scopus 로고
    • Intraoperative dosimetric representation of the real-time ultrasound-guided prostate implant
    • Stock R.G., Stone N.N., and Lo Y.C. Intraoperative dosimetric representation of the real-time ultrasound-guided prostate implant. Tech Urol 6 (2000) 95-98
    • (2000) Tech Urol , vol.6 , pp. 95-98
    • Stock, R.G.1    Stone, N.N.2    Lo, Y.C.3
  • 2
    • 0034266493 scopus 로고    scopus 로고
    • Postimplantation dosimetric analysis of permanent transperineal prostate implantation: Improved dose distributions with an intraoperative computer-optimized conformal planning technique
    • Zelefsky M.J., Yamada Y., Cohen G., et al. Postimplantation dosimetric analysis of permanent transperineal prostate implantation: Improved dose distributions with an intraoperative computer-optimized conformal planning technique. Int J Radiat Oncol Biol Phys 48 (2000) 601-608
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 601-608
    • Zelefsky, M.J.1    Yamada, Y.2    Cohen, G.3
  • 3
    • 0034566040 scopus 로고    scopus 로고
    • Real-time optimized intraoperative dosimetry for prostate brachytherapy: A pilot study
    • Beyer D.C., Shapiro R.H., and Puente F. Real-time optimized intraoperative dosimetry for prostate brachytherapy: A pilot study. Int J Radiat Oncol Biol Phys 48 (2000) 1583-1589
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1583-1589
    • Beyer, D.C.1    Shapiro, R.H.2    Puente, F.3
  • 4
    • 10044257571 scopus 로고    scopus 로고
    • Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose
    • Raben A., Chen H., Grebler A., et al. Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose. Int J Radiat Oncol Biol Phys 60 (2004) 1631-1638
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1631-1638
    • Raben, A.1    Chen, H.2    Grebler, A.3
  • 5
    • 0035450305 scopus 로고    scopus 로고
    • 10-year Biochemical (prostate-specific antigen) control of prostate cancer with (125)I brachytherapy
    • Grimm P.D., Blasko J.C., Sylvester J.E., et al. 10-year Biochemical (prostate-specific antigen) control of prostate cancer with (125)I brachytherapy. Int J Radiat Oncol Biol Phys 51 (2001) 31-40
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 31-40
    • Grimm, P.D.1    Blasko, J.C.2    Sylvester, J.E.3
  • 6
    • 0142227730 scopus 로고    scopus 로고
    • What is the optimal dose for I125 prostate implants? A dose-response analysis of biochemical control, post treatment prostate biopsies, and long term urinary symptoms
    • Stock R.G., Stone N., Dahlal M., et al. What is the optimal dose for I125 prostate implants? A dose-response analysis of biochemical control, post treatment prostate biopsies, and long term urinary symptoms. Brachytherapy 1 (2002) 83-89
    • (2002) Brachytherapy , vol.1 , pp. 83-89
    • Stock, R.G.1    Stone, N.2    Dahlal, M.3
  • 7
    • 0037443428 scopus 로고    scopus 로고
    • Improved conformality and decreased toxicity with intraoperative computer-optimized transperineal ultrasound-guided prostate brachytherapy
    • Zelefsky M.J., Yamada Y., Marion C., et al. Improved conformality and decreased toxicity with intraoperative computer-optimized transperineal ultrasound-guided prostate brachytherapy. Int J Radiat Oncol Biol Phys 55 (2003) 956-963
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 956-963
    • Zelefsky, M.J.1    Yamada, Y.2    Marion, C.3
  • 8
    • 35648937864 scopus 로고    scopus 로고
    • Comparison of 5-year outcomes between conformal LDR brachytherapy and high dose IMRT for patients with clinically localized prostate cancer
    • Abstract S18
    • Zelefsky M.J., Yamada J., Fuks Z., et al. Comparison of 5-year outcomes between conformal LDR brachytherapy and high dose IMRT for patients with clinically localized prostate cancer. Radiother Oncol 37 Suppl. 2 (2004) 71 Abstract S18
    • (2004) Radiother Oncol , vol.37 , Issue.SUPPL. 2 , pp. 71
    • Zelefsky, M.J.1    Yamada, J.2    Fuks, Z.3
  • 9
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources
    • American Association of Physicists in Medicine: Report 61 (Task Group 43)
    • Nath R., Lowell L., Anderson L., et al. Dosimetry of interstitial brachytherapy sources. American Association of Physicists in Medicine: Report 61 (Task Group 43). Med Phys 22 (1995) 209-234
    • (1995) Med Phys , vol.22 , pp. 209-234
    • Nath, R.1    Lowell, L.2    Anderson, L.3
  • 10
    • 8144226372 scopus 로고    scopus 로고
    • Comparison of inverse planning simulated annealing and geometrical optimization for high-dose-rate brachytherapy
    • Hsu I.C., Lessard E., Weinberg V., et al. Comparison of inverse planning simulated annealing and geometrical optimization for high-dose-rate brachytherapy. Brachytherapy 3 (2004) 147-152
    • (2004) Brachytherapy , vol.3 , pp. 147-152
    • Hsu, I.C.1    Lessard, E.2    Weinberg, V.3
  • 11
    • 35649023546 scopus 로고    scopus 로고
    • Chen H, Yang J, Murphy S, et al. Ultrasound guided intra-operative inverse-optimization (US-IOIO) prostate seeds implant: 82 patient results for equivalent target conformity with reduction in urethral and rectal dose. Poster Presentation; 46 Annual AAPM Meeting and Technical Exhibition; Pittsburgh PA, 2004.
  • 12
    • 33845627723 scopus 로고    scopus 로고
    • Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer
    • Zelefsky M.J., Yamada Y., Cohen G., et al. Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 67 (2007) 65-70
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 65-70
    • Zelefsky, M.J.1    Yamada, Y.2    Cohen, G.3
  • 13
    • 33745183567 scopus 로고    scopus 로고
    • Is there a role for postimplant dosimetry after real-time dynamic permanent prostate brachytherapy
    • Potters L., Calugaru E., Jassal A., et al. Is there a role for postimplant dosimetry after real-time dynamic permanent prostate brachytherapy. Int J Radiat Oncol Biol Phys 65 (2006) 1014-1019
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1014-1019
    • Potters, L.1    Calugaru, E.2    Jassal, A.3
  • 14
    • 17144368838 scopus 로고    scopus 로고
    • 12-year Outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer
    • Potters L., Morgenstrn C., Calugaru E., et al. 12-year Outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer. J Urol 173 (2005) 1562-1566
    • (2005) J Urol , vol.173 , pp. 1562-1566
    • Potters, L.1    Morgenstrn, C.2    Calugaru, E.3
  • 15
    • 33846203312 scopus 로고    scopus 로고
    • Multi-institutional analysis of long-term outcome for stages T1-T2 prostate cancer treated with permanent seed implantation
    • Zelefsky M.J., Kuban D.A., Levy L.B., et al. Multi-institutional analysis of long-term outcome for stages T1-T2 prostate cancer treated with permanent seed implantation. Int J Radiat Oncol Biol Phys 67 (2007) 327-333
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 327-333
    • Zelefsky, M.J.1    Kuban, D.A.2    Levy, L.B.3
  • 16
    • 11144356725 scopus 로고    scopus 로고
    • Technical improvement in permanent seed implantation: A two-stage brachytherapy system: Description and comparison with current technique
    • Grimm P.D., Blasko J.C., Sylvester J.E., et al. Technical improvement in permanent seed implantation: A two-stage brachytherapy system: Description and comparison with current technique. Brachytherapy 3 (2004) 34-40
    • (2004) Brachytherapy , vol.3 , pp. 34-40
    • Grimm, P.D.1    Blasko, J.C.2    Sylvester, J.E.3
  • 17
    • 33745610212 scopus 로고    scopus 로고
    • Permanent prostate brachytherapy: Dosimetric analysis of a learning curve with a dynamic dose-feedback technique
    • Acher P., Popert R., Nichol J., et al. Permanent prostate brachytherapy: Dosimetric analysis of a learning curve with a dynamic dose-feedback technique. Int J Radiat Oncol Biol Phys 65 (2006) 694-698
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 694-698
    • Acher, P.1    Popert, R.2    Nichol, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.