메뉴 건너뛰기




Volumn 26, Issue 4, 2007, Pages 549-560

Machining accuracy of crowns by CAD/CAM system using TCP/IP: Influence of restorative material and scanning condition

Author keywords

CAD CAM; Machining accuracy; TCP IP

Indexed keywords


EID: 35548983402     PISSN: 02874547     EISSN: None     Source Type: Journal    
DOI: 10.4012/dmj.26.549     Document Type: Article
Times cited : (11)

References (24)
  • 2
    • 0032059658 scopus 로고    scopus 로고
    • Two years of clinical experience with Procera titanium crowns
    • Milleding P, Haag P, Neroth B, Renz I. Two years of clinical experience with Procera titanium crowns. Int J Prosthodont 1998; 11(3): 224-232.
    • (1998) Int J Prosthodont , vol.11 , Issue.3 , pp. 224-232
    • Milleding, P.1    Haag, P.2    Neroth, B.3    Renz, I.4
  • 3
    • 3042804250 scopus 로고    scopus 로고
    • Inner surface working accuracy of titanium crowns milled with CAD/CAM
    • Shirai M, Shin-ya A, Yokozuka S. Inner surface working accuracy of titanium crowns milled with CAD/CAM. J J Prosthodont Soc 1999; 43(1): 160-170.
    • (1999) J J Prosthodont Soc , vol.43 , Issue.1 , pp. 160-170
    • Shirai, M.1    Shin-ya, A.2    Yokozuka, S.3
  • 4
    • 0345961938 scopus 로고    scopus 로고
    • Working accuracy of CAD/CAM crown restorations with material cuts
    • Ito M, Shin-ya A, Yokozuka S. Working accuracy of CAD/CAM crown restorations with material cuts. J J Prosthodont Soc 1999; 43(3): 614-625.
    • (1999) J J Prosthodont Soc , vol.43 , Issue.3 , pp. 614-625
    • Ito, M.1    Shin-ya, A.2    Yokozuka, S.3
  • 6
    • 0029294810 scopus 로고
    • Use of CAD/CAM system to fabricate dental prostheses. Part 1: CAD for a clinical crown restoration
    • Sohmura T, Takahashi J. Use of CAD/CAM system to fabricate dental prostheses. Part 1: CAD for a clinical crown restoration. Int J Prosthodont 1995; 8(3): 252-258.
    • (1995) Int J Prosthodont , vol.8 , Issue.3 , pp. 252-258
    • Sohmura, T.1    Takahashi, J.2
  • 7
    • 22144432868 scopus 로고    scopus 로고
    • Marginal fitness of composite resin crown fabricated by the dental CAD/CAM system
    • Hikita K, Maeda T, Kobayashi K, Tanaka O, Fujii T, Ohno H, et al. Marginal fitness of composite resin crown fabricated by the dental CAD/CAM system. J J Dent Mater 2002; 5: 294-301.
    • (2002) J J Dent Mater , vol.5 , pp. 294-301
    • Hikita, K.1    Maeda, T.2    Kobayashi, K.3    Tanaka, O.4    Fujii, T.5    Ohno, H.6
  • 8
    • 22144478524 scopus 로고    scopus 로고
    • Time course working accuracy of CAD/CAM titanium crowns restoration with repeat cutting - Durability of tungsten carbide burs
    • Takeuchi Y, Shin-ya A, Matsuda T, Tomita S. Time course working accuracy of CAD/CAM titanium crowns restoration with repeat cutting - Durability of tungsten carbide burs. J J Dent Equip 2003; 9: 26-35.
    • (2003) J J Dent Equip , vol.9 , pp. 26-35
    • Takeuchi, Y.1    Shin-ya, A.2    Matsuda, T.3    Tomita, S.4
  • 9
    • 4344565114 scopus 로고    scopus 로고
    • Durability of tungsten carbide burs for the fabrication of titanium crowns using dental CAD/CAM
    • Hotta Y, Miyazaki T, Fujiwara T, Tomita S, Shin-ya A, Sugai Y, et al. Durability of tungsten carbide burs for the fabrication of titanium crowns using dental CAD/CAM. Dent Mater J 2004; 23(2): 190-196.
    • (2004) Dent Mater J , vol.23 , Issue.2 , pp. 190-196
    • Hotta, Y.1    Miyazaki, T.2    Fujiwara, T.3    Tomita, S.4    Shin-ya, A.5    Sugai, Y.6
  • 10
    • 20644461235 scopus 로고    scopus 로고
    • Machining accuracy of CAD/CAM ceramic crowns fabricated with repeated machining using the same diamond bur
    • Tomita S, Shin-ya A, Gomi H, Matsuda T, Ogura H, Miyazaki T, et al. Machining accuracy of CAD/CAM ceramic crowns fabricated with repeated machining using the same diamond bur. Dent Mater J 2005; 24(1): 123-133.
    • (2005) Dent Mater J , vol.24 , Issue.1 , pp. 123-133
    • Tomita, S.1    Shin-ya, A.2    Gomi, H.3    Matsuda, T.4    Ogura, H.5    Miyazaki, T.6
  • 11
    • 20644456875 scopus 로고    scopus 로고
    • Durability of diamond burs for the fabrication of ceramic crowns using dental CAD/CAM
    • Yara A, Ogura H, Shin-ya A, Tomita S, Miyazaki T, Sugai Y, et al. Durability of diamond burs for the fabrication of ceramic crowns using dental CAD/CAM. Dent Mater J 2005; 24(1): 134-139.
    • (2005) Dent Mater J , vol.24 , Issue.1 , pp. 134-139
    • Yara, A.1    Ogura, H.2    Shin-ya, A.3    Tomita, S.4    Miyazaki, T.5    Sugai, Y.6
  • 12
    • 22144441939 scopus 로고
    • Inner surface form changes of the cast crown using gypsum-bonded investments
    • Konishi M, Watanabe K, Yokozuka S. Inner surface form changes of the cast crown using gypsum-bonded investments. J J Prosthodont Soc 1985; 29(4): 103-120.
    • (1985) J J Prosthodont Soc , vol.29 , Issue.4 , pp. 103-120
    • Konishi, M.1    Watanabe, K.2    Yokozuka, S.3
  • 13
    • 35548972228 scopus 로고
    • Our views on restorations fitness and systematic clinical procedures
    • Nakamura K, Ono Y, Morita K. Our views on restorations fitness and systematic clinical procedures. Practice in Prosthodontics 1987; 20: 673-690.
    • (1987) Practice in Prosthodontics , vol.20 , pp. 673-690
    • Nakamura, K.1    Ono, Y.2    Morita, K.3
  • 14
    • 84995226259 scopus 로고
    • Practical accuracy of the casting method in dentistry
    • Yoshida K. Practical accuracy of the casting method in dentistry. J J Prosthodont Soc 1958; 2: 159-190.
    • (1958) J J Prosthodont Soc , vol.2 , pp. 159-190
    • Yoshida, K.1
  • 15
    • 0033158951 scopus 로고    scopus 로고
    • Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth
    • Beschnidt SM, Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. J Oral Rehabil 1999; 26: 582-593.
    • (1999) J Oral Rehabil , vol.26 , pp. 582-593
    • Beschnidt, S.M.1    Strub, J.R.2
  • 16
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 1993; 51: 129-134.
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 17
    • 0026860865 scopus 로고
    • Non-cast titanium restorations in fixed prosthodontics
    • Boening KW, Walter MH, Reppel PD. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 1992; 19: 281-287.
    • (1992) J Oral Rehabil , vol.19 , pp. 281-287
    • Boening, K.W.1    Walter, M.H.2    Reppel, P.D.3
  • 18
    • 0034328590 scopus 로고    scopus 로고
    • Comparison of two heat-pressed all-ceramic dental materials
    • Gorman CM, McDevitt WE, Hill RG. Comparison of two heat-pressed all-ceramic dental materials. Dent Mater 2000; 16: 389-395.
    • (2000) Dent Mater , vol.16 , pp. 389-395
    • Gorman, C.M.1    McDevitt, W.E.2    Hill, R.G.3
  • 19
    • 0034331731 scopus 로고    scopus 로고
    • The influence of surface roughness on porcelain strength
    • De Jager N, Feilzer AJ, Davidson CL. The influence of surface roughness on porcelain strength. Dent Mater 2000; 16: 381-388.
    • (2000) Dent Mater , vol.16 , pp. 381-388
    • De Jager, N.1    Feilzer, A.J.2    Davidson, C.L.3
  • 20
    • 0035502392 scopus 로고    scopus 로고
    • Procera AllCeram crowns followed for 5 to 10.5 years: A prospective clinical study
    • Odman P, Andersson B. Procera AllCeram crowns followed for 5 to 10.5 years: A prospective clinical study. Int J Prosthodont 2001; 14: 504-509.
    • (2001) Int J Prosthodont , vol.14 , pp. 504-509
    • Odman, P.1    Andersson, B.2
  • 21
    • 2942591034 scopus 로고    scopus 로고
    • Determination of fabricating conditions for the preferable marginal and internal adaptation of the mica crystal castable ceramic crown
    • Ukon S, Ishikawa M, Tohyama M, Sato H. Determination of fabricating conditions for the preferable marginal and internal adaptation of the mica crystal castable ceramic crown. Dent Mater J 2004; 23: 53-62.
    • (2004) Dent Mater J , vol.23 , pp. 53-62
    • Ukon, S.1    Ishikawa, M.2    Tohyama, M.3    Sato, H.4
  • 22
    • 4344647553 scopus 로고    scopus 로고
    • Application of alumina coping to porcelain laminate veneered crown. Part 1: Masking ability for discolored teeth
    • Okamura M, Chen KK, Kakigawa H, Kozono Y. Application of alumina coping to porcelain laminate veneered crown. Part 1: Masking ability for discolored teeth. Dent Mater J 2004; 23: 180-183.
    • (2004) Dent Mater J , vol.23 , pp. 180-183
    • Okamura, M.1    Chen, K.K.2    Kakigawa, H.3    Kozono, Y.4
  • 23
    • 14844357488 scopus 로고    scopus 로고
    • Effect of test method on flexural strength of recent dental ceramics
    • Jin J, Takahashi H, Iwasaki N. Effect of test method on flexural strength of recent dental ceramics. Dent Mater J 2004; 23: 490-496.
    • (2004) Dent Mater J , vol.23 , pp. 490-496
    • Jin, J.1    Takahashi, H.2    Iwasaki, N.3
  • 24
    • 13444311681 scopus 로고    scopus 로고
    • The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns
    • De Jager N, Pallav P, Feilzer AJ. The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. Dent Mater 2005; 21: 242-251.
    • (2005) Dent Mater , vol.21 , pp. 242-251
    • De Jager, N.1    Pallav, P.2    Feilzer, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.