메뉴 건너뛰기




Volumn 43, Issue 3, 2008, Pages 368-377

Characterizing gaseous air cleaner performance in the field

Author keywords

Activated carbon air cleaner; Building study; Indoor air; Model evaluation; VOC transport

Indexed keywords

ACTIVATED CARBON; AIR CLEANERS; AIR QUALITY; INDOOR AIR POLLUTION; VENTILATION DUCTS; VOLATILE ORGANIC COMPOUNDS;

EID: 35548947622     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2006.03.020     Document Type: Article
Times cited : (30)

References (20)
  • 1
    • 85024989865 scopus 로고
    • Volatile organic compounds, indoor air quality and health
    • Molhave L. Volatile organic compounds, indoor air quality and health. Indoor Air 4 (1991) 357-376
    • (1991) Indoor Air , vol.4 , pp. 357-376
    • Molhave, L.1
  • 2
    • 0000467925 scopus 로고    scopus 로고
    • Estimates of improved productivity and health from better indoor environments
    • Fisk W.J., and Rosenfeld A.H. Estimates of improved productivity and health from better indoor environments. Indoor Air 7 (1997) 158-172
    • (1997) Indoor Air , vol.7 , pp. 158-172
    • Fisk, W.J.1    Rosenfeld, A.H.2
  • 3
    • 27644494121 scopus 로고    scopus 로고
    • Performance of air cleaners for removing multiple VOCs in indoor air
    • Chen W., Zhang J.S., and Zhang Z. Performance of air cleaners for removing multiple VOCs in indoor air. ASHRAE Transactions 112 Pt. 1 (2005) 1101-1114
    • (2005) ASHRAE Transactions , vol.112 , Issue.PART 1 , pp. 1101-1114
    • Chen, W.1    Zhang, J.S.2    Zhang, Z.3
  • 4
    • 0028699921 scopus 로고
    • Evaluation of test methods for determining the effectiveness and capacity of gas-phase air filtration equipment for indoor air applications-phase I: literature review and test recommendations
    • VanOsdell D. Evaluation of test methods for determining the effectiveness and capacity of gas-phase air filtration equipment for indoor air applications-phase I: literature review and test recommendations. ASHRAE Transactions 100 Pt. 2 (1994) 511-523
    • (1994) ASHRAE Transactions , vol.100 , Issue.PART 2 , pp. 511-523
    • VanOsdell, D.1
  • 6
    • 27744550572 scopus 로고
    • ASHRAE, American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • ASHRAE. ASHRAE standard 52.1 (1992), American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • (1992) ASHRAE standard 52.1
  • 7
    • 27744570368 scopus 로고    scopus 로고
    • ASHRAE, American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • ASHRAE. ASHRAE standard 52.2 (1999), American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • (1999) ASHRAE standard 52.2
  • 9
  • 10
    • 35548943493 scopus 로고    scopus 로고
    • Walton GN, Dols WS. CONTAM 2.4 user guide and program documentation. NISTIR 7251, National Institute of Standards and Technology, 2005.
  • 11
    • 0024441543 scopus 로고
    • Initial efficiencies of air cleaners for the removal of nitrogen dioxide and volatile organic compounds
    • Daisey J.M., and Hodgson A.T. Initial efficiencies of air cleaners for the removal of nitrogen dioxide and volatile organic compounds. Atmospheric Environment 23 9 (1989) 1885-1892
    • (1989) Atmospheric Environment , vol.23 , Issue.9 , pp. 1885-1892
    • Daisey, J.M.1    Hodgson, A.T.2
  • 12
    • 0035393771 scopus 로고    scopus 로고
    • Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building
    • Emmerich S.J., and Nabinger S.J. Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building. HVAC & R Research 7 3 (2001) 223-244
    • (2001) HVAC & R Research , vol.7 , Issue.3 , pp. 223-244
    • Emmerich, S.J.1    Nabinger, S.J.2
  • 14
    • 0000916190 scopus 로고
    • Effectiveness of portable indoor air cleaners: sensory testing results
    • Shaughnessy R.J., Levetin E., Blocker J., and Sublette K.L. Effectiveness of portable indoor air cleaners: sensory testing results. Indoor Air 4 3 (1994) 179-188
    • (1994) Indoor Air , vol.4 , Issue.3 , pp. 179-188
    • Shaughnessy, R.J.1    Levetin, E.2    Blocker, J.3    Sublette, K.L.4
  • 15
    • 35548942613 scopus 로고    scopus 로고
    • Axley JW. Adsorption modeling for macroscopic contaminant dispersal analysis. NIST-GCR-90-573, Gaithersburg, MD: National Institute of Standards and Technology; 1990.
  • 16
    • 0345724972 scopus 로고    scopus 로고
    • Transient analysis of volatile organic compound concentrations for estimating emission rates
    • Persily A.K., Howard-Reed C., and Nabinger S.J. Transient analysis of volatile organic compound concentrations for estimating emission rates. Atmospheric Environment 37 (2003) 5505-5516
    • (2003) Atmospheric Environment , vol.37 , pp. 5505-5516
    • Persily, A.K.1    Howard-Reed, C.2    Nabinger, S.J.3
  • 18
    • 0032307754 scopus 로고    scopus 로고
    • Using large environmental chamber technique for gaseous contaminants removal equipment test
    • Niu J., Tung T.C.W., and Chui V.W.Y. Using large environmental chamber technique for gaseous contaminants removal equipment test. ASHRAE Transactions 104 2 (1998) 1289-1296
    • (1998) ASHRAE Transactions , vol.104 , Issue.2 , pp. 1289-1296
    • Niu, J.1    Tung, T.C.W.2    Chui, V.W.Y.3
  • 19
    • 35548943936 scopus 로고    scopus 로고
    • Howard-Reed C, Nabinger SJ, Emmerich SJ. Predicting the performance of non-industrial gaseous air cleaners: measurements and model simulations from the pilot study, NISTIR 7114. Gaithersburg, MD: NIST; 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.