메뉴 건너뛰기




Volumn 35, Issue 6, 2007, Pages 637-647

Construction of an optical sensor for cobalt determination based on methyltrioctylammonium chloride immobilized on a polymer membrane

Author keywords

Cobalt; Methyltrioctylammonium chloride; Optical sensor; Spectrophotometry; Thiocyanate; Triacetylcellulose

Indexed keywords

LEACHING; OPTICAL SENSORS; POLYMERIC MEMBRANES; SODIUM COMPOUNDS; SPECTROPHOTOMETRY;

EID: 35448997631     PISSN: 10739149     EISSN: 15256030     Source Type: Journal    
DOI: 10.1080/10739140701651615     Document Type: Article
Times cited : (15)

References (15)
  • 1
    • 35448970304 scopus 로고
    • Encyclopedia Britannica; William
    • Encyclopedia Britannica; William. Benton publisher, 1971, Vol. 5, 986.
    • (1971) Benton publisher , vol.5 , pp. 986
  • 3
    • 33644973818 scopus 로고    scopus 로고
    • Acid extraction & cloud point preconcentration as sample preparation strategies for cobalt determination in biological materials by thermospray flame furnace atomic absorption spectrometry
    • Donati, G.L.; Nascentes, C.C.; Nogueria, A.R.; Arruda, M.A.Z.; Nobrega, J.A. Acid extraction & cloud point preconcentration as sample preparation strategies for cobalt determination in biological materials by thermospray flame furnace atomic absorption spectrometry. Microchem. J. 2006, 82, 189-195.
    • (2006) Microchem. J , vol.82 , pp. 189-195
    • Donati, G.L.1    Nascentes, C.C.2    Nogueria, A.R.3    Arruda, M.A.Z.4    Nobrega, J.A.5
  • 4
    • 23044457822 scopus 로고    scopus 로고
    • Flow injection chemiluminescence determination of femtogram-level cobalt in egg yolk, fish tissue and human serum
    • Song, Z.; Yue, Q.; Wang, C Flow injection chemiluminescence determination of femtogram-level cobalt in egg yolk, fish tissue and human serum. Food Chem. 2006, 94, 457-463.
    • (2006) Food Chem , vol.94 , pp. 457-463
    • Song, Z.1    Yue, Q.2    Wang, C.3
  • 5
    • 0033884284 scopus 로고    scopus 로고
    • Determination of nickel & cobalt in refined beet sugar by adsorptive cathodic stripping voltammetry without sample pretreatment
    • Sancho, D.; Deban, L.; Campos, I.; Pardo, R.; Vega, M. Determination of nickel & cobalt in refined beet sugar by adsorptive cathodic stripping voltammetry without sample pretreatment. Food Chem. 2000, 71, 139-145.
    • (2000) Food Chem , vol.71 , pp. 139-145
    • Sancho, D.1    Deban, L.2    Campos, I.3    Pardo, R.4    Vega, M.5
  • 6
    • 0344474698 scopus 로고    scopus 로고
    • Optosensing of cationic surfactants based on host-guest chemistry
    • Chan, W.H.; Lee, A.W.M.; Lu, J.; Wu, X. Optosensing of cationic surfactants based on host-guest chemistry. Anal. Chim. Acta 1998, 370, 259-266.
    • (1998) Anal. Chim. Acta , vol.370 , pp. 259-266
    • Chan, W.H.1    Lee, A.W.M.2    Lu, J.3    Wu, X.4
  • 7
    • 0037144248 scopus 로고    scopus 로고
    • A flow cell optosensor for determination of Co(II) based on immobilized 2-(4-pyridylazo) resorcinol in chitosan membrane by using stopped flow, flow injection analysis
    • Yusof, N.A.; Ahmad, M. A flow cell optosensor for determination of Co(II) based on immobilized 2-(4-pyridylazo) resorcinol in chitosan membrane by using stopped flow, flow injection analysis. Sens. Actual. B 2002, 86, 127-133.
    • (2002) Sens. Actual. B , vol.86 , pp. 127-133
    • Yusof, N.A.1    Ahmad, M.2
  • 9
    • 2942665715 scopus 로고    scopus 로고
    • Chemically selective membrane optode for Cr(VI) determination in aqueous samples
    • Scindia, Y.M.; Pandey, A.K.; Reddy, A.V.R.; Manohar, S.B. Chemically selective membrane optode for Cr(VI) determination in aqueous samples. Anal. Chim. Acta 2004, 515, 311-321.
    • (2004) Anal. Chim. Acta , vol.515 , pp. 311-321
    • Scindia, Y.M.1    Pandey, A.K.2    Reddy, A.V.R.3    Manohar, S.B.4
  • 10
    • 0000087709 scopus 로고
    • Immobilization of components in polymer membrane-based calcium-selective bulk optodes
    • Rosatzin, T.; Holy, P.; Seiler, K.; Rusterholz, B.; Simon, W. Immobilization of components in polymer membrane-based calcium-selective bulk optodes. Anal. Chem. 1992, 64, 2029.
    • (1992) Anal. Chem , vol.64 , pp. 2029
    • Rosatzin, T.1    Holy, P.2    Seiler, K.3    Rusterholz, B.4    Simon, W.5
  • 11
    • 0032700932 scopus 로고    scopus 로고
    • Evaluation of Nafion-Crystal Violet films for the construction of an optical relative humidity sensor
    • Raimundo, I.M.; Naray anaswamy, R. Evaluation of Nafion-Crystal Violet films for the construction of an optical relative humidity sensor. Analyst 1999, 124, 1623.
    • (1999) Analyst , vol.124 , pp. 1623
    • Raimundo, I.M.1    Naray anaswamy, R.2
  • 12
    • 0037457515 scopus 로고    scopus 로고
    • Characterisation of an optical sensor membrane based on the metal ion indicator Pyrocatechol Violet
    • Steinberg, I.M.; Lobink, A.; Wolfbeis, O.S. Characterisation of an optical sensor membrane based on the metal ion indicator Pyrocatechol Violet. Sens. Actuat. B 2003, 90, 230-235.
    • (2003) Sens. Actuat. B , vol.90 , pp. 230-235
    • Steinberg, I.M.1    Lobink, A.2    Wolfbeis, O.S.3
  • 13
    • 1942536070 scopus 로고    scopus 로고
    • Phenolphthalein immobilized membrane for an optical pH sensor
    • Liu, Z.; Luo, F.; Chen, T. Phenolphthalein immobilized membrane for an optical pH sensor. Anal. Chim. Acta 2004, 510, 189.
    • (2004) Anal. Chim. Acta , vol.510 , pp. 189
    • Liu, Z.1    Luo, F.2    Chen, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.