메뉴 건너뛰기




Volumn 11, Issue 6, 2007, Pages 588-603

Correction of susceptibility artifacts in diffusion tensor data using non-linear registration

Author keywords

Diffusion tensor imaging; Graphics hardware; Neuro navigation; Non linear registration; Susceptibility artifacts

Indexed keywords

BRAIN; NEUROLOGY; OPTIMIZATION; RANDOM PROCESSES; TUMORS;

EID: 35448987602     PISSN: 13618415     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.media.2007.05.004     Document Type: Article
Times cited : (35)

References (55)
  • 1
    • 0030162959 scopus 로고    scopus 로고
    • Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI
    • Basser P., and Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J. Magn. Reson. Imaging 111 (1996) 209-219
    • (1996) J. Magn. Reson. Imaging , vol.111 , pp. 209-219
    • Basser, P.1    Pierpaoli, C.2
  • 2
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser P., Mattiello J., and Le Bihan D. MR diffusion tensor spectroscopy and imaging. Biophys. J 66 1 (1994) 259-267
    • (1994) Biophys. J , vol.66 , Issue.1 , pp. 259-267
    • Basser, P.1    Mattiello, J.2    Le Bihan, D.3
  • 4
    • 0345742632 scopus 로고    scopus 로고
    • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
    • Bodammer N., Kaufmann J., Kanowski M., and Tempelmann C. Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Magn. Reson. Med. 51 1 (2004) 188-193
    • (2004) Magn. Reson. Med. , vol.51 , Issue.1 , pp. 188-193
    • Bodammer, N.1    Kaufmann, J.2    Kanowski, M.3    Tempelmann, C.4
  • 5
    • 0344121124 scopus 로고    scopus 로고
    • White matter fiber tracking in patients with space-occupying lesions of the brain: a new technique for neurosurgical planning?
    • Clark C., Barrick T., Murphy M., and Bell B. White matter fiber tracking in patients with space-occupying lesions of the brain: a new technique for neurosurgical planning?. Neuroimage 20 3 (2003) 1601-1608
    • (2003) Neuroimage , vol.20 , Issue.3 , pp. 1601-1608
    • Clark, C.1    Barrick, T.2    Murphy, M.3    Bell, B.4
  • 6
    • 0034971321 scopus 로고    scopus 로고
    • Three-dimensional visualization of the pyramidal tract in a neuronavigation system during brain tumor surgery: first experiences and technical note
    • Coenen V., Krings T., Mayfrank L., Polin R., Reinges M., Thron A., and Gilsbach J. Three-dimensional visualization of the pyramidal tract in a neuronavigation system during brain tumor surgery: first experiences and technical note. Neurosurgery 49 1 (2001) 86-92
    • (2001) Neurosurgery , vol.49 , Issue.1 , pp. 86-92
    • Coenen, V.1    Krings, T.2    Mayfrank, L.3    Polin, R.4    Reinges, M.5    Thron, A.6    Gilsbach, J.7
  • 9
    • 84948687319 scopus 로고    scopus 로고
    • Guimond, A., Guttmann, C., Warfield, S., Westin, C.-F., 2002. Deformable registration of DT-MRI data based on transformation invariant tensor characteristics. In: Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI).
  • 10
    • 84937917193 scopus 로고    scopus 로고
    • Hastreiter, P., Ertl, T., 1998. Integrated registration and visualization of medical image data. In: Proceedings of the CGI, pp. 78-85.
  • 11
  • 13
    • 84945579359 scopus 로고    scopus 로고
    • Multimodal non-rigid warping for correction of distortions in functional MRI
    • Proceedings of the MICCAI, Springer
    • Hellier P., and Barillot C. Multimodal non-rigid warping for correction of distortions in functional MRI. Proceedings of the MICCAI. Lecture Notes in Computer Science (2000), Springer 512-520
    • (2000) Lecture Notes in Computer Science , pp. 512-520
    • Hellier, P.1    Barillot, C.2
  • 14
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • Jezzard P., and Clare S. Sources of distortion in functional MRI data. Hum. Brain Mapp. 8 2-3 (1999) 80-85
    • (1999) Hum. Brain Mapp. , vol.8 , Issue.2-3 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 16
    • 1442331507 scopus 로고    scopus 로고
    • Intraoperative subcortical stimulation mapping for hemispherical perirolandic gliomas located within or adjacent to the descending motor pathways: evaluation of morbidity and assessment of functional outcome in 294 patients
    • Keles G., Lundin D., Lamborn K., Chang E., Ojemann G., and Berger M. Intraoperative subcortical stimulation mapping for hemispherical perirolandic gliomas located within or adjacent to the descending motor pathways: evaluation of morbidity and assessment of functional outcome in 294 patients. J. Neurosurg. 100 3 (2004) 369-375
    • (2004) J. Neurosurg. , vol.100 , Issue.3 , pp. 369-375
    • Keles, G.1    Lundin, D.2    Lamborn, K.3    Chang, E.4    Ojemann, G.5    Berger, M.6
  • 17
    • 35448989082 scopus 로고    scopus 로고
    • Kindlmann, G., 2004. Superquadric tensor glyphs. In: Proceedings of the IEEE Symposium on Visualization. Eurographics Association, pp. 147-154.
  • 18
    • 15244343082 scopus 로고    scopus 로고
    • Fiber-tracking does not accurately estimate size of fiber bundle in pathological condition: initial neurosurgical experience using neuronavigation and subcortical white matter stimulation
    • Kinoshita M., Yamada K., Hashimoto N., Kato A., Izumoto S., Baba T., Maruno M., Nishimura T., and Yoshimine T. Fiber-tracking does not accurately estimate size of fiber bundle in pathological condition: initial neurosurgical experience using neuronavigation and subcortical white matter stimulation. Neuroimage 25 2 (2005) 424-429
    • (2005) Neuroimage , vol.25 , Issue.2 , pp. 424-429
    • Kinoshita, M.1    Yamada, K.2    Hashimoto, N.3    Kato, A.4    Izumoto, S.5    Baba, T.6    Maruno, M.7    Nishimura, T.8    Yoshimine, T.9
  • 19
    • 0035167926 scopus 로고    scopus 로고
    • Correlation of sensorimotor activation with functional magnetic resonance imaging and magnetoencephalography in presurgical functional imaging: a spatial analysis
    • Kober H., Nimsky C., Möller M., Hastreiter P., Fahlbusch R., and Ganslandt O. Correlation of sensorimotor activation with functional magnetic resonance imaging and magnetoencephalography in presurgical functional imaging: a spatial analysis. NeuroImage 14 5 (2001) 1214-1228
    • (2001) NeuroImage , vol.14 , Issue.5 , pp. 1214-1228
    • Kober, H.1    Nimsky, C.2    Möller, M.3    Hastreiter, P.4    Fahlbusch, R.5    Ganslandt, O.6
  • 22
    • 0036754787 scopus 로고    scopus 로고
    • Distortion correction and robust tensor estimation for MR diffusion imaging
    • Mangin J., Poupon C., Clark C., Le Bihan D., and Bloch I. Distortion correction and robust tensor estimation for MR diffusion imaging. Med. Image Anal. 6 3 (2003) 191-198
    • (2003) Med. Image Anal. , vol.6 , Issue.3 , pp. 191-198
    • Mangin, J.1    Poupon, C.2    Clark, C.3    Le Bihan, D.4    Bloch, I.5
  • 23
    • 0034841912 scopus 로고    scopus 로고
    • Maryak, J., Chin, D., 2001. Global random optimization by simultaneous perturbation stochastic approximation. In: Proceedings of the American Control Conference Arlington, pp. 756-762.
  • 24
    • 84962561067 scopus 로고    scopus 로고
    • Non-linear integration of DTI-based fiber tracts into standard 3D MR data
    • Girod B., Magnor M., and Seidel H.-P. (Eds), Akademische Verlagsgesellschaft AK, Berlin
    • Merhof D., Hastreiter P., Soza G., Stamminger M., and Nimsky C. Non-linear integration of DTI-based fiber tracts into standard 3D MR data. In: Girod B., Magnor M., and Seidel H.-P. (Eds). Proceedings of the Vision, Modeling and Visualization (VMV) (2004), Akademische Verlagsgesellschaft AK, Berlin 371-377
    • (2004) Proceedings of the Vision, Modeling and Visualization (VMV) , pp. 371-377
    • Merhof, D.1    Hastreiter, P.2    Soza, G.3    Stamminger, M.4    Nimsky, C.5
  • 25
    • 0025126149 scopus 로고
    • Simultaneous spatial and spectral selective excitation
    • Meyer C., Pauly J., Macovski A., and Nishimura D. Simultaneous spatial and spectral selective excitation. Magn Reson Med 15 2 (1990) 287-304
    • (1990) Magn Reson Med , vol.15 , Issue.2 , pp. 287-304
    • Meyer, C.1    Pauly, J.2    Macovski, A.3    Nishimura, D.4
  • 26
    • 0036868662 scopus 로고    scopus 로고
    • Fiber tracking: principles and strategies - a technical review
    • Mori S., and van Zijl P. Fiber tracking: principles and strategies - a technical review. NMR Biomed. 15 (2002) 468-480
    • (2002) NMR Biomed. , vol.15 , pp. 468-480
    • Mori, S.1    van Zijl, P.2
  • 27
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • Mori S., Crain B., Chacko V., and van Zijl P. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann. Neurol. 45 2 (1999) 265-269
    • (1999) Ann. Neurol. , vol.45 , Issue.2 , pp. 265-269
    • Mori, S.1    Crain, B.2    Chacko, V.3    van Zijl, P.4
  • 28
    • 0033010152 scopus 로고    scopus 로고
    • Integration of functional magnetic resonance imaging supported by magnetoencephalography in functional neuronavigation
    • Nimsky C., Ganslandt O., Kober H., Möller M., Ulmer S., Tomandl B., and Fahlbusch R. Integration of functional magnetic resonance imaging supported by magnetoencephalography in functional neuronavigation. Neurosurgery 44 (1999) 1249-1256
    • (1999) Neurosurgery , vol.44 , pp. 1249-1256
    • Nimsky, C.1    Ganslandt, O.2    Kober, H.3    Möller, M.4    Ulmer, S.5    Tomandl, B.6    Fahlbusch, R.7
  • 29
    • 0033753708 scopus 로고    scopus 로고
    • Quantification of, visualization of, and compenstation for brain shift by intraoperative magnetic resonance imaging
    • Nimsky C., Ganslandt O., Cerny S., Hastreiter P., Greiner G., and Fahlbusch R. Quantification of, visualization of, and compenstation for brain shift by intraoperative magnetic resonance imaging. Neurosurgery 47 5 (2000) 1070-1080
    • (2000) Neurosurgery , vol.47 , Issue.5 , pp. 1070-1080
    • Nimsky, C.1    Ganslandt, O.2    Cerny, S.3    Hastreiter, P.4    Greiner, G.5    Fahlbusch, R.6
  • 31
    • 10644265259 scopus 로고    scopus 로고
    • Intraoperative diffusion-tensor MR imaging: shifting of white matter tracts during neurosurgical procedures - initial experience
    • Nimsky C., Ganslandt O., Hastreiter P., Wang R., Benner T., Sorensen A., and Fahlbusch R. Intraoperative diffusion-tensor MR imaging: shifting of white matter tracts during neurosurgical procedures - initial experience. Radiology 234 1 (2004) 218-225
    • (2004) Radiology , vol.234 , Issue.1 , pp. 218-225
    • Nimsky, C.1    Ganslandt, O.2    Hastreiter, P.3    Wang, R.4    Benner, T.5    Sorensen, A.6    Fahlbusch, R.7
  • 32
    • 11144230114 scopus 로고    scopus 로고
    • Preoperative and intraoperative diffusion tensor imaging-based fiber tracking in glioma surgery
    • Nimsky C., Ganslandt O., Hastreiter P., Wang R., Benner T., Sorensen A., and Fahlbusch R. Preoperative and intraoperative diffusion tensor imaging-based fiber tracking in glioma surgery. Neurosurgery 56 1 (2005) 130-138
    • (2005) Neurosurgery , vol.56 , Issue.1 , pp. 130-138
    • Nimsky, C.1    Ganslandt, O.2    Hastreiter, P.3    Wang, R.4    Benner, T.5    Sorensen, A.6    Fahlbusch, R.7
  • 33
    • 0033762725 scopus 로고    scopus 로고
    • Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging
    • Nolte U., Finsterbusch J., and Frahm J. Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging. Magn. Reson. Med. 44 5 (2000) 731-736
    • (2000) Magn. Reson. Med. , vol.44 , Issue.5 , pp. 731-736
    • Nolte, U.1    Finsterbusch, J.2    Frahm, J.3
  • 35
    • 84947795329 scopus 로고    scopus 로고
    • The correlation ratio as a new similarity measure for multimodal image registration
    • Proceedings of the MICCAI, Springer
    • Roche A., Malandain G., Pennec X., and Ayache N. The correlation ratio as a new similarity measure for multimodal image registration. Proceedings of the MICCAI. Lecture Notes in Computer Science (1998), Springer 1115-1124
    • (1998) Lecture Notes in Computer Science , pp. 1115-1124
    • Roche, A.1    Malandain, G.2    Pennec, X.3    Ayache, N.4
  • 36
    • 0345742636 scopus 로고    scopus 로고
    • Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI
    • Rohde G., Barnett A., Basser P., Marenco S., and Pierpaoli C. Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI. Magn. Reson. Med. 51 1 (2004) 103-114
    • (2004) Magn. Reson. Med. , vol.51 , Issue.1 , pp. 103-114
    • Rohde, G.1    Barnett, A.2    Basser, P.3    Marenco, S.4    Pierpaoli, C.5
  • 37
    • 0033169211 scopus 로고    scopus 로고
    • Nonrigid Registration Using Free-Form Deformations: Application to Breast MR Images
    • Rueckert D., Sonoda L., Hayes C., Hill D., Leach M., and Hawkes D. Nonrigid Registration Using Free-Form Deformations: Application to Breast MR Images. IEEE Trans Med Img 18 8 (1999) 712-721
    • (1999) IEEE Trans Med Img , vol.18 , Issue.8 , pp. 712-721
    • Rueckert, D.1    Sonoda, L.2    Hayes, C.3    Hill, D.4    Leach, M.5    Hawkes, D.6
  • 40
    • 7544232439 scopus 로고    scopus 로고
    • Correction of high-order eddy current induced geometric distortion in diffusion-weighted echo-planar images
    • Shen Y., Larkman D., Counsell S., Pu I., Edwards D., and Hajnal J. Correction of high-order eddy current induced geometric distortion in diffusion-weighted echo-planar images. Magn. Reson. Med. 52 5 (2004) 1184-1189
    • (2004) Magn. Reson. Med. , vol.52 , Issue.5 , pp. 1184-1189
    • Shen, Y.1    Larkman, D.2    Counsell, S.3    Pu, I.4    Edwards, D.5    Hajnal, J.6
  • 41
    • 35448944108 scopus 로고    scopus 로고
    • Sierra, R., 2001. Nonrigid Registration of Diffusion Tensor Images. M.Phil. thesis, Swiss Federal Institute of Technology Zurich. SPL Technical Report No. 207.
  • 42
    • 0036828879 scopus 로고    scopus 로고
    • Fast Robust Automated Brain Extraction
    • Smith S. Fast Robust Automated Brain Extraction. Hum Brain Mapp 17 3 (2002) 143-155
    • (2002) Hum Brain Mapp , vol.17 , Issue.3 , pp. 143-155
    • Smith, S.1
  • 43
    • 35449002590 scopus 로고    scopus 로고
    • Soza, G. 2005. Registration and Simulation for the Analysis of the Intraoperative Brain Shift. Ph.D. thesis, Computer Graphics Group, Computer Science Department, University of Erlangen-Nuremberg.
  • 44
    • 84944029893 scopus 로고    scopus 로고
    • Non-rigid registration with use of hardware-based 3D Bézier functions
    • Proceedings of the MICCAI, Springer
    • Soza G., Bauer M., Hastreiter P., Nimsky Ch., and Greiner G. Non-rigid registration with use of hardware-based 3D Bézier functions. Proceedings of the MICCAI. Lecture Notes in Computer Science 2489 (2000), Springer 549-556
    • (2000) Lecture Notes in Computer Science , vol.2489 , pp. 549-556
    • Soza, G.1    Bauer, M.2    Hastreiter, P.3    Nimsky, Ch.4    Greiner, G.5
  • 45
    • 20344363639 scopus 로고    scopus 로고
    • Estimating mechanical brain tissue properties with simulation and registration
    • Proceedings of the MICCAI, Springer
    • Soza G., Grosso R., Nimsky C., Greiner G., and Hastreiter P. Estimating mechanical brain tissue properties with simulation and registration. Proceedings of the MICCAI. Lecture Notes in Computer Science vol. 3217 (2000), Springer 276-283
    • (2000) Lecture Notes in Computer Science , vol.3217 , pp. 276-283
    • Soza, G.1    Grosso, R.2    Nimsky, C.3    Greiner, G.4    Hastreiter, P.5
  • 46
    • 0032117046 scopus 로고    scopus 로고
    • Implementation of the simultaneous perturbation algorithm for stochastic optimization
    • Spall J. Implementation of the simultaneous perturbation algorithm for stochastic optimization. IEEE Trans. Aero. Electron. Syst. 34 3 (1998) 817-823
    • (1998) IEEE Trans. Aero. Electron. Syst. , vol.34 , Issue.3 , pp. 817-823
    • Spall, J.1
  • 47
    • 0034290982 scopus 로고    scopus 로고
    • Adaptive stochastic approximation by the simultaneous perturbation method
    • Spall J. Adaptive stochastic approximation by the simultaneous perturbation method. IEEE Trans. Autom. Control 45 (2000) 1839-1853
    • (2000) IEEE Trans. Autom. Control , vol.45 , pp. 1839-1853
    • Spall, J.1
  • 48
    • 0013124576 scopus 로고    scopus 로고
    • Spall, J., Hill, S., Stark, D., 1999. Theoretical comparisons of evolutionary computation and other optimization approaches. In: Proceedings of the Congress on Evolutionary Computation, pp. 1398-1405.
  • 49
    • 0026839090 scopus 로고
    • Multivariate stochastic approximation using a simultaneous perturbation gradient approximation
    • Spall J.C. Multivariate stochastic approximation using a simultaneous perturbation gradient approximation. IEEE Trans. Autom. Control 37 3 (1992) 332-341
    • (1992) IEEE Trans. Autom. Control , vol.37 , Issue.3 , pp. 332-341
    • Spall, J.C.1
  • 50
    • 35448954163 scopus 로고    scopus 로고
    • Studholme, C., Hill, D., Hawkes, D., 1996. Automated 3D registration of truncated MR and CT images of the head. In: Proc Brit. Mach. Vis. Conf. (BMVC), pp. 27-37.
  • 51
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • Studholme C., Hill D., and Hawkes D. An overlap invariant entropy measure of 3D medical image alignment. Pattern Recogn. 32 1 (1999) 71-86
    • (1999) Pattern Recogn. , vol.32 , Issue.1 , pp. 71-86
    • Studholme, C.1    Hill, D.2    Hawkes, D.3
  • 52
    • 38249019523 scopus 로고
    • Improved hard-pulse sequences for frequency-selective presaturation in magnetic resonance
    • Weisskoff R. Improved hard-pulse sequences for frequency-selective presaturation in magnetic resonance. J. Magn. Reson. 86 1 (1990) 170-175
    • (1990) J. Magn. Reson. , vol.86 , Issue.1 , pp. 170-175
    • Weisskoff, R.1
  • 53
    • 35448929598 scopus 로고    scopus 로고
    • Wells, W., Viola, P., Kikinis, R., 1995. Multi-modal volume registration by maximization of mutual information. In: Proc. Med. Robot. and Comput Assis. Surg., pp. 55-62.
  • 54
    • 0030088712 scopus 로고    scopus 로고
    • Multi-modal volume registration by maximization of mutual information
    • Wells W., Viola P., Atsumi H., Nakajima S., and Kikinis R. Multi-modal volume registration by maximization of mutual information. Med. Image Anal. 1 1 (1997) 35-51
    • (1997) Med. Image Anal. , vol.1 , Issue.1 , pp. 35-51
    • Wells, W.1    Viola, P.2    Atsumi, H.3    Nakajima, S.4    Kikinis, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.