메뉴 건너뛰기




Volumn 80, Issue 5, 1998, Pages 343-346

Systemic thrombolysis causing anastomotic dehiscence of an aortobifemoral graft

Author keywords

Aortic graft dehiscence; Thrombolysis

Indexed keywords

DACRON; FIBRINOLYTIC AGENT; HEPARIN; PHORBOL 12 ACETATE 13 MYRISTATE; STREPTOKINASE; UROKINASE;

EID: 3543103137     PISSN: 00358843     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (11)
  • 2
    • 0032474229 scopus 로고    scopus 로고
    • ISIS-2: 10 year survival among patients with suspected acute myocardial infarction in randomised comparison of intravenous streptokinase, oral aspirin, both or neither
    • Baigent C, Collins R, Appleby P et al. on behalf of the ISIS-2 (Second International Study of Infarct Survival) Collaborative Group. ISIS-2: 10 year survival among patients with suspected acute myocardial infarction in randomised comparison of intravenous streptokinase, oral aspirin, both or neither. BMJ 1998; 316: 1337-43.
    • (1998) BMJ , vol.316 , pp. 1337-1343
    • Baigent, C.1    Collins, R.2    Appleby, P.3
  • 3
    • 0027240597 scopus 로고
    • An international randomized trial comparing four thrombolytic strategies for acute mycoardial infarction
    • The GUSTO investigators. An international randomized trial comparing four thrombolytic strategies for acute mycoardial infarction. N Engl J Med 1993; 329: 673-82.
    • (1993) N Engl J Med , vol.329 , pp. 673-682
  • 4
    • 3543082823 scopus 로고
    • Thrombolytic therapy for acute vascular emergencies
    • Greenlagh RM, Hollier LH, eds. London: Saunders
    • Hamilton G, Dawson K. Thrombolytic therapy for acute vascular emergencies. In: Greenlagh RM, Hollier LH, eds. Emergency Vascular Surgery. London: Saunders, 1992: 37-54.
    • (1992) Emergency Vascular Surgery , pp. 37-54
    • Hamilton, G.1    Dawson, K.2
  • 5
    • 0028860688 scopus 로고
    • The performance of commercially available sealed Dacron vascular grafts in intra-arterial thrombolytic therapy
    • Trudell AL, Whittemore AD, Sunwoo MH. The performance of commercially available sealed Dacron vascular grafts in intra-arterial thrombolytic therapy. ASAIO J 1995; 41: 633-5.
    • (1995) ASAIO J , vol.41 , pp. 633-635
    • Trudell, A.L.1    Whittemore, A.D.2    Sunwoo, M.H.3
  • 6
    • 0022456588 scopus 로고
    • Transgraft haemorrhage: A serious commplication of low-dose thrombolytic therapy
    • Perler BA, Kinnison M, Halden WJ. Transgraft haemorrhage: a serious commplication of low-dose thrombolytic therapy. J Vasc Surg 1986; 3: 936-8.
    • (1986) J Vasc Surg , vol.3 , pp. 936-938
    • Perler, B.A.1    Kinnison, M.2    Halden, W.J.3
  • 7
    • 0021320496 scopus 로고
    • Contrast extravasation from a Gore-Tex graft: A complication of thrombolytic therapy
    • Becker GJ, Holden RW, Rabe FE. Contrast extravasation from a Gore-Tex graft: a complication of thrombolytic therapy. AJR 1984; 142: 573-1.
    • (1984) AJR , vol.142 , pp. 573-581
    • Becker, G.J.1    Holden, R.W.2    Rabe, F.E.3
  • 8
    • 0020027748 scopus 로고
    • Contrast extravasation through Dacron grafts: A sequela of low-dose streptokinase therapy
    • Rabe FE, Becker GJ, Richmond BD et al. Contrast extravasation through Dacron grafts: a sequela of low-dose streptokinase therapy. AJR 1982; 138: 917-20.
    • (1982) AJR , vol.138 , pp. 917-920
    • Rabe, F.E.1    Becker, G.J.2    Richmond, B.D.3
  • 9
    • 0027135813 scopus 로고
    • Remote transgraft haemorrhage complicating thrombolysis with tissue plasminogen activator
    • Ward AS, Cripps N. Remote transgraft haemorrhage complicating thrombolysis with tissue plasminogen activator. AJR 1993; 161: 1335-6
    • (1993) AJR , vol.161 , pp. 1335-1336
    • Ward, A.S.1    Cripps, N.2
  • 10
    • 0030907292 scopus 로고    scopus 로고
    • Aortic transgraft hemorrhage after systemic thrombolytic therapy
    • Pope M, Kalman PG. Aortic transgraft hemorrhage after systemic thrombolytic therapy. Ann Vasc Surg 1997; 11: 292-4.
    • (1997) Ann Vasc Surg , vol.11 , pp. 292-294
    • Pope, M.1    Kalman, P.G.2
  • 11
    • 0027176083 scopus 로고
    • Systemic thrombolysis causing haemorrhage around a prosthetic abdominal aortic graft
    • London NJM, Williams B, Stein A. Systemic thrombolysis causing haemorrhage around a prosthetic abdominal aortic graft. BMJ 1993; 306: 1530-31.
    • (1993) BMJ , vol.306 , pp. 1530-1531
    • London, N.J.M.1    Williams, B.2    Stein, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.