메뉴 건너뛰기




Volumn 26, Issue 2, 2004, Pages 239-247

A new computer model of mitral valve hemodynamics during ventricular filling

Author keywords

Computer model; Flow; Mitral valve; Pressure; Valve replacement

Indexed keywords

ANIMAL EXPERIMENT; AORTA FLOW; BLOOD VISCOSITY; COMPUTER MODEL; CONDUCTANCE; CONFERENCE PAPER; CONTROLLED STUDY; CORRELATION ANALYSIS; DIASTOLE; FLOWMETER; HEART VENTRICLE FILLING; HEART VENTRICLE PRESSURE; HEMODYNAMICS; MITRAL VALVE; MITRAL VALVE REPLACEMENT; NONHUMAN; PRIORITY JOURNAL; VALIDATION PROCESS;

EID: 3543081519     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2004.03.018     Document Type: Conference Paper
Times cited : (20)

References (22)
  • 1
    • 0024575259 scopus 로고
    • Fluid dynamics model of mitral valve flow: Description with in-vitro validation
    • Thomas J.D., Weyman A. Fluid dynamics model of mitral valve flow: description with in-vitro validation. J Am Coll Cardiol. 13:1989;221-233
    • (1989) J Am Coll Cardiol , vol.13 , pp. 221-233
    • Thomas, J.D.1    Weyman, A.2
  • 4
    • 0032982843 scopus 로고    scopus 로고
    • Prognostic value of disastolic filling parameters derived using a novel image processing technique in patients>or=70 years of age with congestive heart failure
    • Rich M.W., Sitziel N.O., Kovacs S.J. Prognostic value of disastolic filling parameters derived using a novel image processing technique in patients>or=70 years of age with congestive heart failure. Am J Cardiol. 84:1999;82-86
    • (1999) Am J Cardiol , vol.84 , pp. 82-86
    • Rich, M.W.1    Sitziel, N.O.2    Kovacs, S.J.3
  • 5
    • 0025935203 scopus 로고
    • Echocardiographic Doppler evaluation of left ventricular diastolic function
    • Thomas J.D., Weyman A. Echocardiographic Doppler evaluation of left ventricular diastolic function. Circulation. 84:1991;977-990
    • (1991) Circulation , vol.84 , pp. 977-990
    • Thomas, J.D.1    Weyman, A.2
  • 6
    • 0037929691 scopus 로고    scopus 로고
    • Sequential assessment of mitral valve area during diastole using colour M-mode flow convergence analysis: New insights into mitral stenosis physiology
    • Messika-Zeitoun D., Yiu S.F., Cormier B., Iung B., Scott C., Vahanian A., Tajik A.J., Enriquez-Sarano M. Sequential assessment of mitral valve area during diastole using colour M-mode flow convergence analysis: new insights into mitral stenosis physiology. Eur Heart J. 24:2003;1244-1253
    • (2003) Eur Heart J , vol.24 , pp. 1244-1253
    • Messika-Zeitoun, D.1    Yiu, S.F.2    Cormier, B.3    Iung, B.4    Scott, C.5    Vahanian, A.6    Tajik, A.J.7    Enriquez-Sarano, M.8
  • 8
    • 0031915713 scopus 로고    scopus 로고
    • Difference in tranmitral flow velocity pattern during increased preload in patients with abnormal left ventricular relaxation
    • Yamada H., Oki T., Tabata T., Manabe K., Fukuda K., Abbe M., Iuschi A. Difference in tranmitral flow velocity pattern during increased preload in patients with abnormal left ventricular relaxation. Cardiology. 89:1998;152-158
    • (1998) Cardiology , vol.89 , pp. 152-158
    • Yamada, H.1    Oki, T.2    Tabata, T.3    Manabe, K.4    Fukuda, K.5    Abbe, M.6    Iuschi, A.7
  • 9
    • 0035138587 scopus 로고    scopus 로고
    • Effect of cardiac output on mitral valve area in patients with mitral stenosis: Validation and pitfalls of the pressure half-time method
    • Firstenberg M.S., Prior D.L., Greenberg N.L., Vahi S., Pasquet A., Garcia M.J., Thomas J.D. Effect of cardiac output on mitral valve area in patients with mitral stenosis: validation and pitfalls of the pressure half-time method. J Heart Valve Dis. 10:2001;49-56
    • (2001) J Heart Valve Dis , vol.10 , pp. 49-56
    • Firstenberg, M.S.1    Prior, D.L.2    Greenberg, N.L.3    Vahi, S.4    Pasquet, A.5    Garcia, M.J.6    Thomas, J.D.7
  • 10
    • 0026771274 scopus 로고
    • Numerical modeling of ventricular filling
    • Thomas J.D., Weyman A. Numerical modeling of ventricular filling. Ann Biomed Eng. 20:1992;19-39
    • (1992) Ann Biomed Eng , vol.20 , pp. 19-39
    • Thomas, J.D.1    Weyman, A.2
  • 11
    • 0026507741 scopus 로고
    • Calculation of atrioventricular compliance from the mitral flow profile: Analytic and in-vitro study
    • Flachskampf F., Weyman A., Guerrero J.L., Thomas J.D. Calculation of atrioventricular compliance from the mitral flow profile: analytic and in-vitro study. J Am Coll Cardiol. 19:1992;998-1004
    • (1992) J Am Coll Cardiol , vol.19 , pp. 998-1004
    • Flachskampf, F.1    Weyman, A.2    Guerrero, J.L.3    Thomas, J.D.4
  • 12
    • 0029154619 scopus 로고
    • Comparison of diastolic filling models and their fit to transmitral Doppler contours
    • Nudelman S., Manson A., Hall A., Kovacs S. Comparison of diastolic filling models and their fit to transmitral Doppler contours. Ultrasound Med Biol. 21:1995;989-999
    • (1995) Ultrasound Med Biol , vol.21 , pp. 989-999
    • Nudelman, S.1    Manson, A.2    Hall, A.3    Kovacs, S.4
  • 13
    • 0034176173 scopus 로고    scopus 로고
    • Three-dimensional computational model of left heart diastolic function with fluid-structure interaction
    • Lemmon J.D., Yoganathan A.P. Three-dimensional computational model of left heart diastolic function with fluid-structure interaction. J Biomech Eng. 122:2000;109-117
    • (2000) J Biomech Eng , vol.122 , pp. 109-117
    • Lemmon, J.D.1    Yoganathan, A.P.2
  • 14
    • 0033804590 scopus 로고    scopus 로고
    • Computational modeling of left heart diastolic function: Examination of ventricular dysfunction
    • Lemmon J.D., Yoganathan A.P. Computational modeling of left heart diastolic function: examination of ventricular dysfunction. J Biomech Eng. 122:2000;297-303
    • (2000) J Biomech Eng , vol.122 , pp. 297-303
    • Lemmon, J.D.1    Yoganathan, A.P.2
  • 15
    • 0037086306 scopus 로고    scopus 로고
    • Peak early diastolic velocity rather than pressure half time is the best index of mechanical prosthetic mitral valve function
    • Fernadez V., Olmos L., Nagueh S.F., Quinones M.A., Zoghbi V.A. Peak early diastolic velocity rather than pressure half time is the best index of mechanical prosthetic mitral valve function. Am L Cardiol. 89:2002;704-710
    • (2002) Am L Cardiol , vol.89 , pp. 704-710
    • Fernadez, V.1    Olmos, L.2    Nagueh, S.F.3    Quinones, M.A.4    Zoghbi, V.A.5
  • 16
    • 85047676676 scopus 로고
    • The effect of flow on Doppler estimates of bioprosthetic mitral valve function in vitro
    • Chambers J.B., Cochrane T., Black M.M., Jackson G. The effect of flow on Doppler estimates of bioprosthetic mitral valve function in vitro. Cardiovasc Res. 23:1989;1007-1114
    • (1989) Cardiovasc Res , vol.23 , pp. 1007-1114
    • Chambers, J.B.1    Cochrane, T.2    Black, M.M.3    Jackson, G.4
  • 17
    • 50449114923 scopus 로고
    • Hydraulic formula for calculation of the area of the stenotic mitral valve other cardiac valves, and central circulatory shunts
    • Gorlin R., Gorlin S.G. Hydraulic formula for calculation of the area of the stenotic mitral valve other cardiac valves, and central circulatory shunts. Am Heart J. 41:1951;1-29
    • (1951) Am Heart J , vol.41 , pp. 1-29
    • Gorlin, R.1    Gorlin, S.G.2
  • 18
    • 0026883824 scopus 로고
    • A theoretical model for the noninvasive assessment of the transmitral pressure-flow relation
    • Isaaz K. A theoretical model for the noninvasive assessment of the transmitral pressure-flow relation. J Biomech. 25:1992;581-590
    • (1992) J Biomech , vol.25 , pp. 581-590
    • Isaaz, K.1
  • 19
    • 0029310679 scopus 로고
    • Dynamic characteristics of prosthetic heart valves
    • She J., Li M., Huan L., Yu Y. Dynamic characteristics of prosthetic heart valves. Med Eng Phys. 17:1995;273-281
    • (1995) Med Eng Phys , vol.17 , pp. 273-281
    • She, J.1    Li, M.2    Huan, L.3    Yu, Y.4
  • 20
    • 0037368361 scopus 로고    scopus 로고
    • Model and influence of mitral valve opening during left ventricular filling
    • Baccani B., Domenichini F., Pedrizzetti G. Model and influence of mitral valve opening during left ventricular filling. J Biomech. 36:2003;355-361
    • (2003) J Biomech , vol.36 , pp. 355-361
    • Baccani, B.1    Domenichini, F.2    Pedrizzetti, G.3
  • 21
    • 0034066428 scopus 로고    scopus 로고
    • A lumped parameter model of left ventricular filling - Pressure waveforms
    • Waite L.R., Schulz S., Szabó G., Vahl C.F. A lumped parameter model of left ventricular filling - pressure waveforms. Biomed Sci Inst. 36:2000;75-80
    • (2000) Biomed Sci Inst , vol.36 , pp. 75-80
    • Waite, L.R.1    Schulz, S.2    Szabó, G.3    Vahl, C.F.4
  • 22
    • 0025155204 scopus 로고
    • Effects of preload reduction on mitral flow velocity pattern in normal subjects
    • Triulzi M.O., Castini D., Urnagi M., Vitolo E. Effects of preload reduction on mitral flow velocity pattern in normal subjects. Am J Cardiol. 66:1990;995-1001
    • (1990) Am J Cardiol , vol.66 , pp. 995-1001
    • Triulzi, M.O.1    Castini, D.2    Urnagi, M.3    Vitolo, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.