-
2
-
-
0029861737
-
Risk factors for corneal endothelial injury during phacoemulsification
-
Hayashi K., Hayashi H., Nakao F., and Hayashi F. Risk factors for corneal endothelial injury during phacoemulsification. J Cataract Refract Surg 22 (1996) 1079-1084
-
(1996)
J Cataract Refract Surg
, vol.22
, pp. 1079-1084
-
-
Hayashi, K.1
Hayashi, H.2
Nakao, F.3
Hayashi, F.4
-
3
-
-
0033777636
-
Keratopathy in pseudoexfoliation syndrome as a cause of corneal endothelial decompensation; a clinicopathologic study
-
Naumann G.O.H., and Schlötzer-Schrehardt U. Keratopathy in pseudoexfoliation syndrome as a cause of corneal endothelial decompensation; a clinicopathologic study. Ophthalmology 107 (2000) 1111-1124
-
(2000)
Ophthalmology
, vol.107
, pp. 1111-1124
-
-
Naumann, G.O.H.1
Schlötzer-Schrehardt, U.2
-
4
-
-
0034034338
-
Endothelial cell loss after phacoemulsification: relation to preoperative and intraoperative parameters
-
Walkow T., Anders N., and Klebe S. Endothelial cell loss after phacoemulsification: relation to preoperative and intraoperative parameters. J Cataract Refract Surg 26 (2000) 727-732
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 727-732
-
-
Walkow, T.1
Anders, N.2
Klebe, S.3
-
5
-
-
0030051384
-
Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision
-
Dick H.B., Kohnen T., Jacobi F.K., and Jacobi K.W. Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision. J Cataract Refract Surg 22 (1996) 63-71
-
(1996)
J Cataract Refract Surg
, vol.22
, pp. 63-71
-
-
Dick, H.B.1
Kohnen, T.2
Jacobi, F.K.3
Jacobi, K.W.4
-
6
-
-
0001793450
-
Dispersive and cohesive viscoelastic materials in phacoemulsification
-
Arshinoff S.A. Dispersive and cohesive viscoelastic materials in phacoemulsification. Ophthalmic Pract 13 (1995) 98-104
-
(1995)
Ophthalmic Pract
, vol.13
, pp. 98-104
-
-
Arshinoff, S.A.1
-
7
-
-
0032952529
-
Dispersive-cohesive viscoelastic soft shell technique
-
Arshinoff S.A. Dispersive-cohesive viscoelastic soft shell technique. J Cataract Refract Surg 25 (1999) 167-173
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 167-173
-
-
Arshinoff, S.A.1
-
8
-
-
0036734405
-
Efficacy and safety of the soft-shell technique in cases with a hard lens nucleus
-
Miyata K., Nagamoto T., Maruoka S., et al. Efficacy and safety of the soft-shell technique in cases with a hard lens nucleus. J Cataract Refract Surg 28 (2002) 1546-1550
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1546-1550
-
-
Miyata, K.1
Nagamoto, T.2
Maruoka, S.3
-
9
-
-
0027173798
-
The Lens Opacities Classification System III; the Longitudinal Study of Cataract Surgery Group
-
Chylack Jr. L.T., Wolfe J.K., Singer D.M., et al. The Lens Opacities Classification System III; the Longitudinal Study of Cataract Surgery Group. Arch Ophthalmol 111 (1993) 831-836
-
(1993)
Arch Ophthalmol
, vol.111
, pp. 831-836
-
-
Chylack Jr., L.T.1
Wolfe, J.K.2
Singer, D.M.3
-
10
-
-
0019366255
-
Endothelial mosaic in Fuchs' dystrophy; a qualitative evaluation with specular microscope
-
Laing R.A., Leibowitz H.M., Oak S.S., et al. Endothelial mosaic in Fuchs' dystrophy; a qualitative evaluation with specular microscope. Arch Ophthalmol 99 (1981) 80-83
-
(1981)
Arch Ophthalmol
, vol.99
, pp. 80-83
-
-
Laing, R.A.1
Leibowitz, H.M.2
Oak, S.S.3
-
12
-
-
33845225200
-
Trends of penetrating keratoplasty in the United States from 1980 to 2004
-
Darlington J.K., Adrean S.D., and Schwab I.R. Trends of penetrating keratoplasty in the United States from 1980 to 2004. Ophthalmology 113 (2006) 2171-2175
-
(2006)
Ophthalmology
, vol.113
, pp. 2171-2175
-
-
Darlington, J.K.1
Adrean, S.D.2
Schwab, I.R.3
-
13
-
-
0034078089
-
Indications for and outcomes of repeat penetrating keratoplasty, 1989-1995
-
Patel N.P., Kim T., Rapuano C.J., et al. Indications for and outcomes of repeat penetrating keratoplasty, 1989-1995. Ophthalmology 107 (2000) 719-724
-
(2000)
Ophthalmology
, vol.107
, pp. 719-724
-
-
Patel, N.P.1
Kim, T.2
Rapuano, C.J.3
-
14
-
-
0031917461
-
New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration
-
Poyer J.F., Chan K.Y., and Arshinoff S.A. New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration. J Cataract Refract Surg 24 (1998) 84-90
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 84-90
-
-
Poyer, J.F.1
Chan, K.Y.2
Arshinoff, S.A.3
-
15
-
-
0027477587
-
A comparison of corneal endothelial changes after use of Healon or Viscoat during phacoemulsification
-
Koch D.D., Liu J.F., Glasser D.B., et al. A comparison of corneal endothelial changes after use of Healon or Viscoat during phacoemulsification. Am J Ophthalmol 115 (1993) 188-201
-
(1993)
Am J Ophthalmol
, vol.115
, pp. 188-201
-
-
Koch, D.D.1
Liu, J.F.2
Glasser, D.B.3
-
16
-
-
0030968815
-
Corneal endothelial protection by different viscoelastics during phacoemulsification
-
Ravalico G., Tognetto D., Baccara F., and Lovisato A. Corneal endothelial protection by different viscoelastics during phacoemulsification. J Cataract Refract Surg 23 (1997) 433-439
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 433-439
-
-
Ravalico, G.1
Tognetto, D.2
Baccara, F.3
Lovisato, A.4
-
17
-
-
0035164381
-
Influence of viscoelastic substances used in cataract surgery on corneal metabolism and endothelial morphology: comparison of Healon and Viscoat
-
Maár N., Graebe A., Schild G., et al. Influence of viscoelastic substances used in cataract surgery on corneal metabolism and endothelial morphology: comparison of Healon and Viscoat. J Cataract Refract Surg 27 (2001) 1756-1761
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1756-1761
-
-
Maár, N.1
Graebe, A.2
Schild, G.3
-
18
-
-
0033485537
-
Randomized clinical comparison of Healon GV and Viscoat
-
Miller K.M., and Colvard D.M. Randomized clinical comparison of Healon GV and Viscoat. J Cataract Refract Surg 25 (1999) 1630-1636
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 1630-1636
-
-
Miller, K.M.1
Colvard, D.M.2
-
19
-
-
23944509784
-
Comparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification
-
Accessed July 23, 2007
-
Vajpayee R.B., Verma K., Sinha R., et al. Comparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification. BMC Ophthalmol 5 1 (2005) 17. http://www.biomedcentral.com/1471-2415/5/17 Accessed July 23, 2007
-
(2005)
BMC Ophthalmol
, vol.5
, Issue.1
, pp. 17
-
-
Vajpayee, R.B.1
Verma, K.2
Sinha, R.3
-
20
-
-
0033765877
-
Healon5 versus Viscoat during cataract surgery: intraocular pressure, laser flare and corneal changes
-
Schwenn O., Dick H.B., Krummenauer F., et al. Healon5 versus Viscoat during cataract surgery: intraocular pressure, laser flare and corneal changes. Graefes Arch Clin Exp Ophthalmol 238 (2000) 861-867
-
(2000)
Graefes Arch Clin Exp Ophthalmol
, vol.238
, pp. 861-867
-
-
Schwenn, O.1
Dick, H.B.2
Krummenauer, F.3
-
21
-
-
0033252411
-
Comparison of the effect of Healon® vs Viscoat® on endothelial cell count after phacoemulsification and posterior chamber lens implantation
-
Cosemans I., Zeyen P., and Zeyen T. Comparison of the effect of Healon® vs Viscoat® on endothelial cell count after phacoemulsification and posterior chamber lens implantation. Bull Soc Belge Ophtalmol 274 (1999) 87-92
-
(1999)
Bull Soc Belge Ophtalmol
, vol.274
, pp. 87-92
-
-
Cosemans, I.1
Zeyen, P.2
Zeyen, T.3
-
22
-
-
0036734185
-
Using BSS with viscoadaptives in the ultimate soft-shell technique
-
Arshinoff S.A. Using BSS with viscoadaptives in the ultimate soft-shell technique. J Cataract Refract Surg 28 (2002) 1509-1514
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1509-1514
-
-
Arshinoff, S.A.1
-
23
-
-
7044239166
-
Efficacy of the soft-shell technique using Viscoat and Hyal-2000
-
Kim H., and Joo C.-K. Efficacy of the soft-shell technique using Viscoat and Hyal-2000. J Cataract Refract Surg 30 (2004) 2366-2370
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 2366-2370
-
-
Kim, H.1
Joo, C.-K.2
-
24
-
-
0036732665
-
Transient corneal edema after phacoemulsification: comparison of 3 viscoelastic regimens
-
Behndig A., and Lundberg B. Transient corneal edema after phacoemulsification: comparison of 3 viscoelastic regimens. J Cataract Refract Surg 28 (2002) 1551-1556
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1551-1556
-
-
Behndig, A.1
Lundberg, B.2
-
25
-
-
0026769470
-
Effects of Healon vs. Viscoat on endothelial cell count and morphology after phacoemulsification and posterior chamber lens implantation
-
Rafuse P.E., and Nichols B.D. Effects of Healon vs. Viscoat on endothelial cell count and morphology after phacoemulsification and posterior chamber lens implantation. Can J Ophthalmol 27 (1992) 125-129
-
(1992)
Can J Ophthalmol
, vol.27
, pp. 125-129
-
-
Rafuse, P.E.1
Nichols, B.D.2
-
26
-
-
8744261987
-
Increased intraocular pressure and corneal endothelial cell loss following phacoemulsification surgery
-
Yachimori R., Matsuura T., Hayashi K., and Hayashi H. Increased intraocular pressure and corneal endothelial cell loss following phacoemulsification surgery. Ophthalmic Surg Lasers Imaging 35 (2004) 453-459
-
(2004)
Ophthalmic Surg Lasers Imaging
, vol.35
, pp. 453-459
-
-
Yachimori, R.1
Matsuura, T.2
Hayashi, K.3
Hayashi, H.4
-
27
-
-
35349024652
-
-
Arshinoff SA. Rock 'n' roll removal of Healon GV. In: Arshinoff SA, ed, Proceedings of the 7th Annual National Ophthalmic Speakers Program, Ottawa, June 1997. Quebec, Canada, Medicopea, 1997; 29-30
-
-
-
-
28
-
-
0034109128
-
Two-compartment technique to remove ophthalmic viscosurgical devices
-
Tetz M.R., and Holzer M.P. Two-compartment technique to remove ophthalmic viscosurgical devices. J Cataract Refract Surg 26 (2000) 641-643
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 641-643
-
-
Tetz, M.R.1
Holzer, M.P.2
-
29
-
-
0035166071
-
Corneal thickness and endothelial density before and after cataract surgery
-
Ventura A.C.S., Wälti R., and Böhnke M. Corneal thickness and endothelial density before and after cataract surgery. Br J Ophthalmol 85 (2001) 18-20
-
(2001)
Br J Ophthalmol
, vol.85
, pp. 18-20
-
-
Ventura, A.C.S.1
Wälti, R.2
Böhnke, M.3
-
30
-
-
0023676322
-
Positive correlation of corneal thickness and endothelial cell loss; serial measurements after cataract surgery
-
Cheng H., Bates A.K., Wood L., and McPherson K. Positive correlation of corneal thickness and endothelial cell loss; serial measurements after cataract surgery. Arch Ophthalmol 106 (1988) 920-922
-
(1988)
Arch Ophthalmol
, vol.106
, pp. 920-922
-
-
Cheng, H.1
Bates, A.K.2
Wood, L.3
McPherson, K.4
-
31
-
-
14644396483
-
Cataract surgery in patients with Fuchs' corneal dystrophy; expanding recommendations for cataract surgery without simultaneous keratoplasty
-
Seitzman G.D., Gottsch J.D., and Stark W.J. Cataract surgery in patients with Fuchs' corneal dystrophy; expanding recommendations for cataract surgery without simultaneous keratoplasty. Ophthalmology 112 (2005) 441-446
-
(2005)
Ophthalmology
, vol.112
, pp. 441-446
-
-
Seitzman, G.D.1
Gottsch, J.D.2
Stark, W.J.3
|