메뉴 건너뛰기




Volumn 54, Issue 5, 2007, Pages 1568-1573

GATE Monte Carlo simulation of a high-sensitivity and high-resolution LSO-based small animal PET camera

Author keywords

GATE; Geant4; Monte Carlo simulations; Positron emission tomography (PET)

Indexed keywords

LUTETIUM OXYORTHOSILICATE; SMALL ANIMAL POSITRON EMISSION TOMOGRAPHY;

EID: 35348992262     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2007.905165     Document Type: Article
Times cited : (11)

References (19)
  • 1
    • 0028493623 scopus 로고    scopus 로고
    • W.-H. Wong, J. Uribe, K. Hicks, and M. Zambelli, A 2-dimensional detector decoding study on BGO arrays with quadrant sharing photomultipliers, IEEE Trans. Nucl. Sci., 4.1, pp. 1453-1457, Jun. 1994.
    • W.-H. Wong, J. Uribe, K. Hicks, and M. Zambelli, "A 2-dimensional detector decoding study on BGO arrays with quadrant sharing photomultipliers, " IEEE Trans. Nucl. Sci., vol. 4.1, pp. 1453-1457, Jun. 1994.
  • 2
    • 34648825417 scopus 로고    scopus 로고
    • Front end electronics for a variable field PET camera using the PMT-quadrant-sharing detector array design
    • Jun
    • W.-H. Wong, G. Hu, N. Zhang, J. Uribe, J. Wang, H. Li, H. Baghaei, and S. Yokoyama, "Front end electronics for a variable field PET camera using the PMT-quadrant-sharing detector array design," IEEE Trans. Nucl. Sci., vol. 44, pp. 1266-1270, Jun. 1997.
    • (1997) IEEE Trans. Nucl. Sci , vol.44 , pp. 1266-1270
    • Wong, W.-H.1    Hu, G.2    Zhang, N.3    Uribe, J.4    Wang, J.5    Li, H.6    Baghaei, H.7    Yokoyama, S.8
  • 3
    • 0033355614 scopus 로고    scopus 로고
    • Prototype electronics for a variable field of view PET camera using the PMT-quadrant-sharing detector array
    • Jun
    • H. Li, W.-H. Wong, N. Zhang, J. Wang, J. Uribe, H. Baghaei, and S. Yokoyama, "Prototype electronics for a variable field of view PET camera using the PMT-quadrant-sharing detector array," IEEE Trans. Nucl. Sci., vol. 46, pp. 546-550, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci , vol.46 , pp. 546-550
    • Li, H.1    Wong, W.-H.2    Zhang, N.3    Wang, J.4    Uribe, J.5    Baghaei, H.6    Yokoyama, S.7
  • 4
    • 0035043959 scopus 로고    scopus 로고
    • Feasibility of a high-speed gamma-camera design using the high-yield-pileup-eventrecovery method
    • Apr
    • W.-H. Wong, H. Li, J. Uribe, and H. Baghaei, "Feasibility of a high-speed gamma-camera design using the high-yield-pileup-eventrecovery method," J. Nucl. Med., vol. 42, pp. 624-632, Apr. 2001.
    • (2001) J. Nucl. Med , vol.42 , pp. 624-632
    • Wong, W.-H.1    Li, H.2    Uribe, J.3    Baghaei, H.4
  • 7
    • 0034092414 scopus 로고    scopus 로고
    • Scintillation crystals for PET
    • Jun
    • C. L. Melcher, "Scintillation crystals for PET," J. Nucl. Med., vol. 41, pp. 1051-1055, Jun. 2000.
    • (2000) J. Nucl. Med , vol.41 , pp. 1051-1055
    • Melcher, C.L.1
  • 9
    • 0142063357 scopus 로고    scopus 로고
    • GATE: A Geant4-based simulation platform for PET and SPETC integrating movement and time management
    • Oct
    • G. Santin, D. Strul, D. Lazaro, L. Simon, M. Krieguer, M. V. Martins, V. Breton, and C. Morel, "GATE: A Geant4-based simulation platform for PET and SPETC integrating movement and time management," IEEE Trans. Nucl. Sci., vol. 50, pp. 1516-1521, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 1516-1521
    • Santin, G.1    Strul, D.2    Lazaro, D.3    Simon, L.4    Krieguer, M.5    Martins, M.V.6    Breton, V.7    Morel, C.8
  • 13
    • 23844499173 scopus 로고    scopus 로고
    • Monte carlo simulation for the ECAT EXACT HR+ system using GATE
    • Jun
    • S. Jan, C. Comat, D. Strul, G. Santin, and R. trebossen, "Monte carlo simulation for the ECAT EXACT HR+ system using GATE," IEEE Trans. Nucl Sci., vol. 52, pp. 627-633, Jun. 2005.
    • (2005) IEEE Trans. Nucl Sci , vol.52 , pp. 627-633
    • Jan, S.1    Comat, C.2    Strul, D.3    Santin, G.4    trebossen, R.5
  • 14
    • 35349018935 scopus 로고    scopus 로고
    • H. Baghaei, W.-H. Wong, J. Uribe, H. Li, N. Zhang, and Y. Wang, The correction factors for a high resolution variable field of view PET camera, J. Nucl. Med., 40, p. 279 P. May 1999.
    • H. Baghaei, W.-H. Wong, J. Uribe, H. Li, N. Zhang, and Y. Wang, "The correction factors for a high resolution variable field of view PET camera," J. Nucl. Med., vol. 40, p. 279 P. May 1999.
  • 15
    • 23844515766 scopus 로고    scopus 로고
    • A method of determination of the timing stability of PET scanners
    • Aug
    • C. J. Thompson and A. L. Goertzen, "A method of determination of the timing stability of PET scanners," IEEE. Trans. Med. Imaging, vol. 24, pp. 1053-1057, Aug. 2005.
    • (2005) IEEE. Trans. Med. Imaging , vol.24 , pp. 1053-1057
    • Thompson, C.J.1    Goertzen, A.L.2
  • 16
    • 0024610693 scopus 로고
    • Analytic 3D image reconstruction using all detected events
    • Feb
    • P. E. Kinahan and J. G. Rogers, "Analytic 3D image reconstruction using all detected events," IEEE Trans. Nucl. Sci., vol. 36, pp. 964-968, Feb. 1989.
    • (1989) IEEE Trans. Nucl. Sci , vol.36 , pp. 964-968
    • Kinahan, P.E.1    Rogers, J.G.2
  • 17
    • 0037291830 scopus 로고    scopus 로고
    • Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm
    • Feb
    • H. Baghaei, W.-H. Wong, H. Li, J. Uribe, Y. Wang, M. Aykac, Y. Liu, and T. Xing, "Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm," IEEE Trans. Nucl. Sci., vol. 50, pp. 3-8, Feb. 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 3-8
    • Baghaei, H.1    Wong, W.-H.2    Li, H.3    Uribe, J.4    Wang, Y.5    Aykac, M.6    Liu, Y.7    Xing, T.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.