메뉴 건너뛰기




Volumn 127, Issue 2, 2007, Pages 350-357

High-sensitivity, large dynamic range, auto-calibration methane optical sensor using a short confocal Fabry-Perot cavity

Author keywords

Auto calibration; Confocal Fabry Perot cavity; Methane sensor; Optical gas sensor

Indexed keywords

CALIBRATION; CHEMICAL SENSORS; LIGHT AMPLIFIERS; LIGHT REFLECTION; METHANE; SENSITIVITY ANALYSIS;

EID: 35348946421     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.04.030     Document Type: Article
Times cited : (24)

References (33)
  • 1
    • 84975568168 scopus 로고
    • Atomes a I'Interieur d'un interferometre Perot-Fabry
    • Kastler A. Atomes a I'Interieur d'un interferometre Perot-Fabry. Appl. Opt. 1 1 (1962) 17-24
    • (1962) Appl. Opt. , vol.1 , Issue.1 , pp. 17-24
    • Kastler, A.1
  • 2
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
    • O'Keefe A., and Deacon D.A.G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources. Rev. Sci. Instrum. 59 (1988) 2544-2551
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2544-2551
    • O'Keefe, A.1    Deacon, D.A.G.2
  • 5
    • 0000840755 scopus 로고    scopus 로고
    • Cavity-enhanced absorption spectroscopy of molecular oxygen
    • Gianfrani L. Cavity-enhanced absorption spectroscopy of molecular oxygen. J. Opt. Soc. Am. B 16 12 (1999) 2247-2254
    • (1999) J. Opt. Soc. Am. B , vol.16 , Issue.12 , pp. 2247-2254
    • Gianfrani, L.1
  • 8
    • 0032326827 scopus 로고    scopus 로고
    • Ultrasensitive detection in atomic and molecular physics: demonstration in molecular overtone spectroscopy
    • Ye J., Ma L.S., and Hall J.L. Ultrasensitive detection in atomic and molecular physics: demonstration in molecular overtone spectroscopy. J. Opt. Soc. Am. B 15 1 (1998) 6-15
    • (1998) J. Opt. Soc. Am. B , vol.15 , Issue.1 , pp. 6-15
    • Ye, J.1    Ma, L.S.2    Hall, J.L.3
  • 9
    • 0034536080 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy: experimental schemes and applications
    • Berden G., Peeters R., and Meijer G. Cavity ring-down spectroscopy: experimental schemes and applications. Int. Rev. Phys. Chem. 19 4 (2000) 565-670
    • (2000) Int. Rev. Phys. Chem. , vol.19 , Issue.4 , pp. 565-670
    • Berden, G.1    Peeters, R.2    Meijer, G.3
  • 11
    • 0001406681 scopus 로고    scopus 로고
    • Tunable diode-laser absorption measurements of methane at elevated temperatures
    • Nagali V., Chou S.I., Baer D.S., Hanson R.K., and Swgall J. Tunable diode-laser absorption measurements of methane at elevated temperatures. Appl. Opt. 35 (1996) 4026-4032
    • (1996) Appl. Opt. , vol.35 , pp. 4026-4032
    • Nagali, V.1    Chou, S.I.2    Baer, D.S.3    Hanson, R.K.4    Swgall, J.5
  • 14
    • 84975606805 scopus 로고
    • Trace gas detection using 1.3 μm InGaAsP diode laser transmitter modules
    • Cassidy D.T. Trace gas detection using 1.3 μm InGaAsP diode laser transmitter modules. Appl. Opt. 27 (1988) 610-614
    • (1988) Appl. Opt. , vol.27 , pp. 610-614
    • Cassidy, D.T.1
  • 15
    • 11144284189 scopus 로고    scopus 로고
    • A portable remote methane detector using an InGaAsP DFB laser
    • Iseki T. A portable remote methane detector using an InGaAsP DFB laser. Environ. Geol. 46 (2004) 1064-1069
    • (2004) Environ. Geol. , vol.46 , pp. 1064-1069
    • Iseki, T.1
  • 16
    • 0032045241 scopus 로고    scopus 로고
    • Sensitive detection of methane with a 1.65 μm diode laser by photoacoustic and absorption spectroscopy
    • Schäfer S., Mashni M., Sneider J., Miklós A., Hess P., Pitz H., Pleban K.-U., and Ebert V. Sensitive detection of methane with a 1.65 μm diode laser by photoacoustic and absorption spectroscopy. Appl. Phys. B 66 (1998) 511-516
    • (1998) Appl. Phys. B , vol.66 , pp. 511-516
    • Schäfer, S.1    Mashni, M.2    Sneider, J.3    Miklós, A.4    Hess, P.5    Pitz, H.6    Pleban, K.-U.7    Ebert, V.8
  • 17
    • 0030707978 scopus 로고    scopus 로고
    • Real-time monitoring of environmental methane and other gases with semiconductor lasers: a review
    • Uehara K., Tai H., and Kimura K. Real-time monitoring of environmental methane and other gases with semiconductor lasers: a review. Sens. Actuators B: Chem. 38-39 (1997) 136-140
    • (1997) Sens. Actuators B: Chem. , vol.38-39 , pp. 136-140
    • Uehara, K.1    Tai, H.2    Kimura, K.3
  • 18
    • 84975633475 scopus 로고
    • Remote detection of methane with a 1.66 μm diode laser
    • Uehara K., and Tai H. Remote detection of methane with a 1.66 μm diode laser. Appl. Opt. 31 (1992) 809-814
    • (1992) Appl. Opt. , vol.31 , pp. 809-814
    • Uehara, K.1    Tai, H.2
  • 19
    • 0028438861 scopus 로고
    • Highly sensitive detection of molecular absorption using a high finesse optical cavity
    • Nakagawa K., Katsuda T., Shelkovnikov A.S., de Labachelerie M., and Ohtsu M. Highly sensitive detection of molecular absorption using a high finesse optical cavity. Opt. Commun. 107 (1994) 369-372
    • (1994) Opt. Commun. , vol.107 , pp. 369-372
    • Nakagawa, K.1    Katsuda, T.2    Shelkovnikov, A.S.3    de Labachelerie, M.4    Ohtsu, M.5
  • 20
    • 0032761907 scopus 로고    scopus 로고
    • 2 using a 1064 nm Nd:YAG laser
    • 2 using a 1064 nm Nd:YAG laser. Appl. Phys. B 68 (1999) 99-105
    • (1999) Appl. Phys. B , vol.68 , pp. 99-105
    • Inbar, E.1    Arie, A.2
  • 21
    • 0033175308 scopus 로고    scopus 로고
    • Sensitivity enhancement for acetylene detection at 1.5 μm by use of a high-finesse optical cavity
    • Okazawa R., Kuze H., Masusaki H., and Takeuchi N. Sensitivity enhancement for acetylene detection at 1.5 μm by use of a high-finesse optical cavity. Jpn. J. Appl. Phys. 38 (1999) 4946-4949
    • (1999) Jpn. J. Appl. Phys. , vol.38 , pp. 4946-4949
    • Okazawa, R.1    Kuze, H.2    Masusaki, H.3    Takeuchi, N.4
  • 22
    • 24144434057 scopus 로고    scopus 로고
    • Theoretical analysis of cavity saturation spectroscopy of weak molecular absorbance
    • Ma W.G., Dong L., Yin W.B., and Jia S.T. Theoretical analysis of cavity saturation spectroscopy of weak molecular absorbance. Chin. Phys. 14 (2005) 709-713
    • (2005) Chin. Phys. , vol.14 , pp. 709-713
    • Ma, W.G.1    Dong, L.2    Yin, W.B.3    Jia, S.T.4
  • 23
    • 0031646834 scopus 로고    scopus 로고
    • New field formulas for the Fabry-Perot interferometer and their application to ultrasound detection
    • Shan Q., Bradford A.S., and Dewhurst R.J. New field formulas for the Fabry-Perot interferometer and their application to ultrasound detection. Meas. Sci. Technol. 9 (1998) 24-37
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 24-37
    • Shan, Q.1    Bradford, A.S.2    Dewhurst, R.J.3
  • 24
    • 84975581083 scopus 로고
    • The spherical mirror Fabry-Perot interferometer
    • Hercher M. The spherical mirror Fabry-Perot interferometer. Appl. Opt. 7 (1968) 951-966
    • (1968) Appl. Opt. , vol.7 , pp. 951-966
    • Hercher, M.1
  • 26
    • 0037146184 scopus 로고    scopus 로고
    • Effects of laser phase noise on the injection of a high-finesse cavity
    • Morville J., Romanini D., Chenevier M., and Kachanov A. Effects of laser phase noise on the injection of a high-finesse cavity. Appl. Opt. 41 (2002) 6980-6990
    • (2002) Appl. Opt. , vol.41 , pp. 6980-6990
    • Morville, J.1    Romanini, D.2    Chenevier, M.3    Kachanov, A.4
  • 30
    • 21944445724 scopus 로고    scopus 로고
    • Analytical and experimental study of ringing effects in a Fabry-Perot cavity. Application to the measurement of high finesses
    • Poirson J., Bretenaker F., Valler M., and Floch A.L. Analytical and experimental study of ringing effects in a Fabry-Perot cavity. Application to the measurement of high finesses. J. Opt. Soc. Am. B 14 11 (1997) 2811-2817
    • (1997) J. Opt. Soc. Am. B , vol.14 , Issue.11 , pp. 2811-2817
    • Poirson, J.1    Bretenaker, F.2    Valler, M.3    Floch, A.L.4
  • 33
    • 0001650650 scopus 로고    scopus 로고
    • Ammonia detection by use of near-infrared diode-laser-based overtone spectroscopy
    • Claps R., Englich F.V., Leleux D.P., Richter D., Rittel F.K., and Curl R.F. Ammonia detection by use of near-infrared diode-laser-based overtone spectroscopy. Appl. Opt. 40 24 (2001) 4387-4394
    • (2001) Appl. Opt. , vol.40 , Issue.24 , pp. 4387-4394
    • Claps, R.1    Englich, F.V.2    Leleux, D.P.3    Richter, D.4    Rittel, F.K.5    Curl, R.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.