메뉴 건너뛰기




Volumn 66, Issue 5, 2007, Pages 1018-1022

Epinephrine volume reduction of giant colon polyps facilitates endoscopic assessment and removal

Author keywords

[No Author keywords available]

Indexed keywords

ADRENALIN;

EID: 35348939049     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gie.2007.03.1078     Document Type: Article
Times cited : (41)

References (18)
  • 1
    • 0027086973 scopus 로고
    • Colonoscopy: a prospective report of complications
    • Waye J.D., Lewis B.S., and Yessayan S. Colonoscopy: a prospective report of complications. J Clin Gastroenterol 15 (1992) 347-351
    • (1992) J Clin Gastroenterol , vol.15 , pp. 347-351
    • Waye, J.D.1    Lewis, B.S.2    Yessayan, S.3
  • 2
    • 21544450322 scopus 로고    scopus 로고
    • Handcrafted two-channel colonoscope for grasping-forceps-assisted resection of giant pedunculated polyps
    • Matsushita M., Takakuwa H., Matsubayashi Y., et al. Handcrafted two-channel colonoscope for grasping-forceps-assisted resection of giant pedunculated polyps. Gastrointest Endosc 62 (2005) 132-136
    • (2005) Gastrointest Endosc , vol.62 , pp. 132-136
    • Matsushita, M.1    Takakuwa, H.2    Matsubayashi, Y.3
  • 3
    • 0034803306 scopus 로고    scopus 로고
    • Endoscopic snare excision of large pedunculated colorectal polyps: a new, safe, and effective technique
    • Brandimarte G., and Tursi A. Endoscopic snare excision of large pedunculated colorectal polyps: a new, safe, and effective technique. Gastrointest Endosc 33 (2001) 854-857
    • (2001) Gastrointest Endosc , vol.33 , pp. 854-857
    • Brandimarte, G.1    Tursi, A.2
  • 4
    • 0031834760 scopus 로고    scopus 로고
    • Ineffective use of a detachable snare for colonoscopic polypectomy of large polyps
    • Matsushita M., Hajiro K., Takakuwa H., et al. Ineffective use of a detachable snare for colonoscopic polypectomy of large polyps. Gastrointest Endosc 47 (1998) 496-499
    • (1998) Gastrointest Endosc , vol.47 , pp. 496-499
    • Matsushita, M.1    Hajiro, K.2    Takakuwa, H.3
  • 5
    • 30944469621 scopus 로고    scopus 로고
    • Endoscopic resection with hypertonic saline-solution-epinephrine injection plus band ligation for large pedunculated or semipedunculated gastric polyp
    • Akahoshi K., Yoshimaga S., Fujimaru T., et al. Endoscopic resection with hypertonic saline-solution-epinephrine injection plus band ligation for large pedunculated or semipedunculated gastric polyp. Gastrointest Endosc 63 (2006) 312-316
    • (2006) Gastrointest Endosc , vol.63 , pp. 312-316
    • Akahoshi, K.1    Yoshimaga, S.2    Fujimaru, T.3
  • 6
    • 0034771151 scopus 로고    scopus 로고
    • Is submucosal epinephrine injection necessary before polypectomy? A prospective, comparative study
    • Hsieh Y.H., Lin H.J., Tseng G.Y., et al. Is submucosal epinephrine injection necessary before polypectomy? A prospective, comparative study. Hepatogastroenterology 48 (2001) 1379-1382
    • (2001) Hepatogastroenterology , vol.48 , pp. 1379-1382
    • Hsieh, Y.H.1    Lin, H.J.2    Tseng, G.Y.3
  • 7
    • 17144456682 scopus 로고    scopus 로고
    • Endoscopic resection of large colorectal polyps
    • Perez R., Gonzalez C., Legaz H., et al. Endoscopic resection of large colorectal polyps. Rev Esp Enferm Dig 96 (2004) 36-47
    • (2004) Rev Esp Enferm Dig , vol.96 , pp. 36-47
    • Perez, R.1    Gonzalez, C.2    Legaz, H.3
  • 8
    • 35348981159 scopus 로고    scopus 로고
    • Waye JD. Postpolypectomy hemorrhage, UpToDateonline 2004: http://www.utdol.com/application/topic.asp?file=gi_endos/7727. Accessed December 1, 2005.
  • 9
    • 0029879760 scopus 로고    scopus 로고
    • Endoscopic snare excision of "giant" colorectal polyps
    • Binmoeller K.F., Bohnacker S., Seifert H., et al. Endoscopic snare excision of "giant" colorectal polyps. Gastrointest Endosc 43 (1996) 183-188
    • (1996) Gastrointest Endosc , vol.43 , pp. 183-188
    • Binmoeller, K.F.1    Bohnacker, S.2    Seifert, H.3
  • 10
    • 4444370300 scopus 로고    scopus 로고
    • A survey of colonoscopic polypectomy practices among clinical gastroenterologists
    • Singh N., Harrison M., and Rex D.K. A survey of colonoscopic polypectomy practices among clinical gastroenterologists. Gastrointest Endosc 60 (2004) 414-418
    • (2004) Gastrointest Endosc , vol.60 , pp. 414-418
    • Singh, N.1    Harrison, M.2    Rex, D.K.3
  • 11
    • 0031473713 scopus 로고    scopus 로고
    • Colonoscopic resection of large colonic polyps-a prospective study
    • Bardan E., Bat L., Melzer E., et al. Colonoscopic resection of large colonic polyps-a prospective study. Isr J Med Sci 33 (1997) 777-780
    • (1997) Isr J Med Sci , vol.33 , pp. 777-780
    • Bardan, E.1    Bat, L.2    Melzer, E.3
  • 13
    • 0027477544 scopus 로고
    • Preliminary evaluation of the prototype stereoscopic endoscope: precise three-dimensional measurement system
    • Catalano M.F., Van Dam J., Bedford R., et al. Preliminary evaluation of the prototype stereoscopic endoscope: precise three-dimensional measurement system. Gastrointest Endosc 39 (1993) 23-28
    • (1993) Gastrointest Endosc , vol.39 , pp. 23-28
    • Catalano, M.F.1    Van Dam, J.2    Bedford, R.3
  • 14
    • 0027399541 scopus 로고
    • Are endoscopic measurements of colonic polyps reliable?
    • Fennerty M.B., Davidson J., Emerson S.S., et al. Are endoscopic measurements of colonic polyps reliable?. Am J Gastroenterol 88 (1993) 496-500
    • (1993) Am J Gastroenterol , vol.88 , pp. 496-500
    • Fennerty, M.B.1    Davidson, J.2    Emerson, S.S.3
  • 15
    • 0030069197 scopus 로고    scopus 로고
    • The difference in colon polyp size before and after removal
    • Morales T.G., Sampliner R.E., Garewal H.S., et al. The difference in colon polyp size before and after removal. Gastrointest Endosc 43 (1996) 25-28
    • (1996) Gastrointest Endosc , vol.43 , pp. 25-28
    • Morales, T.G.1    Sampliner, R.E.2    Garewal, H.S.3
  • 17
    • 0031445946 scopus 로고    scopus 로고
    • Is in vivo measurement of size of polyps during colonoscopy accurate?
    • Gopalswamy N., Shenoy V.N., Choudhry U., et al. Is in vivo measurement of size of polyps during colonoscopy accurate?. Gastrointest Endosc 46 (1997) 497-502
    • (1997) Gastrointest Endosc , vol.46 , pp. 497-502
    • Gopalswamy, N.1    Shenoy, V.N.2    Choudhry, U.3
  • 18
    • 0031473581 scopus 로고    scopus 로고
    • The pathologic measurement of polyp size is preferable to the endoscopic estimate
    • Schoen R.E., Gerber L.D., and Margulies G. The pathologic measurement of polyp size is preferable to the endoscopic estimate. Gastrointest Endosc 46 (1997) 492-496
    • (1997) Gastrointest Endosc , vol.46 , pp. 492-496
    • Schoen, R.E.1    Gerber, L.D.2    Margulies, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.