메뉴 건너뛰기




Volumn , Issue , 2006, Pages

Real time issues for dynamic security assessment

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC EQUIPMENT PROTECTION; ENVIRONMENTAL IMPACT; REAL TIME CONTROL; TRANSIENTS; VOLTAGE CONTROL;

EID: 35348901373     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/pes.2006.1709329     Document Type: Conference Paper
Times cited : (4)

References (11)
  • 1
    • 0024034051 scopus 로고
    • Foundations of the potential energy boundary surface method for power system transient stability analysis
    • June
    • H.D. Chiang, F.F. Wu and P.P. Varaya, "Foundations of the potential energy boundary surface method for power system transient stability analysis". IEEE Transactions on Circuits and Systems, Vol.35, No.6, June 1988, pp.712-728;
    • (1988) IEEE Transactions on Circuits and Systems , vol.35 , Issue.6 , pp. 712-728
    • Chiang, H.D.1    Wu, F.F.2    Varaya, P.P.3
  • 2
    • 0028481811 scopus 로고
    • A BCU method for direct analysis of power system transient stability
    • August
    • H.D. Chiang, F.F. Wu, P.P. Varaya, "A BCU method for direct analysis of power system transient stability", IEEE Transactions on Power Systems, Vol.9, No.3, August 1994, pp.1194-1208;
    • (1994) IEEE Transactions on Power Systems , vol.9 , Issue.3 , pp. 1194-1208
    • Chiang, H.D.1    Wu, F.F.2    Varaya, P.P.3
  • 3
    • 0002225811 scopus 로고
    • Transient stability analysis of electrical power system via Lure Type Lyapunov function. Parts I and II
    • N. Kakimoto, Y. Ohsawa, M. Hayashi, "Transient stability analysis of electrical power system via Lure Type Lyapunov function. Parts I and II", IEE Transactions of Japan 98, 1978, pp.63-79;
    • (1978) IEE Transactions of Japan , vol.98 , pp. 63-79
    • Kakimoto, N.1    Ohsawa, Y.2    Hayashi, M.3
  • 6
    • 35348839844 scopus 로고    scopus 로고
    • CIGRE TF 38.02.17, Advanced angle stability controls, Brochure Number 155, Electra, April 2000;
    • CIGRE TF 38.02.17, Advanced angle stability controls, Brochure Number 155, Electra, April 2000;
  • 7
    • 35348898056 scopus 로고    scopus 로고
    • Symposium on reliability criteria for system dynamic performance
    • Symposium on reliability criteria for system dynamic performance, IEEE - PES Publication, No. 77, CH 1221 - PW, 2003;
    • (2003) IEEE - PES Publication, No. 77, CH 1221 - PW
  • 8
    • 0035254437 scopus 로고    scopus 로고
    • Dynamic gradient method for PEBS detection in power system transient stability assessment
    • J.T. Scruggs, L. Mili, "Dynamic gradient method for PEBS detection in power system transient stability assessment", International Journal of Electrical Power & Energy Systems, vol.23, pp. 155-165, 2001;
    • (2001) International Journal of Electrical Power & Energy Systems , vol.23 , pp. 155-165
    • Scruggs, J.T.1    Mili, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.