메뉴 건너뛰기




Volumn , Issue , 2007, Pages 660-663

Notice of Retraction: Study of MIT phase sensitivity for detecting a brain edema based on FDTD method

Author keywords

Brain edema; Electromagnetic computation; Finite difference time domain method; Head model; Helix antenna; Magnetic induction tomography; Phase detection

Indexed keywords

ANTENNAS; FINITE DIFFERENCE TIME DOMAIN METHOD; MAGNETIC FIELD EFFECTS; MATHEMATICAL MODELS; PARAMETER ESTIMATION; TOMOGRAPHY;

EID: 35348876649     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBBE.2007.172     Document Type: TB
Times cited : (6)

References (13)
  • 1
    • 0027360406 scopus 로고
    • Contactless impedance measurement by magnetic induction - a possible method for investigation of brain impedance
    • J. Netz, E. Fornert and S. Haagemann, "Contactless impedance measurement by magnetic induction - a possible method for investigation of brain impedance," Physiol. Meas, vol. 14, pp. 463-471, 1993.
    • (1993) Physiol. Meas , vol.14 , pp. 463-471
    • Netz, J.1    Fornert, E.2    Haagemann, S.3
  • 2
    • 0035111823 scopus 로고    scopus 로고
    • Magnetic induction tomography: Hardware for multi-frequency measurements in biological tissues
    • H. Scharfetter, H. K. Lackner and J. Rosell, "Magnetic induction tomography: hardware for multi-frequency measurements in biological tissues," Physiol. Meas, vol. 22, pp 131 -146, 2001.
    • (2001) Physiol. Meas , vol.22 , pp. 131-146
    • Scharfetter, H.1    Lackner, H.K.2    Rosell, J.3
  • 3
    • 0035422248 scopus 로고    scopus 로고
    • Magnetic induction tomography
    • H. Griffiths, "Magnetic induction tomography" Meas. Sci. Technol, vol. 12, pp. 1126-1131, 2001.
    • (2001) Meas. Sci. Technol , vol.12 , pp. 1126-1131
    • Griffiths, H.1
  • 4
    • 1342332813 scopus 로고    scopus 로고
    • Detection of brain oedema using magnetic induction tomography: A feasibility study of the likely sensitivity and detectability
    • R. Merwa, K. Hollaus and H. Scharfetter, "Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability," Physiol. Meas, vol. 25, pp. 1-8, 2004.
    • (2004) Physiol. Meas , vol.25 , pp. 1-8
    • Merwa, R.1    Hollaus, K.2    Scharfetter, H.3
  • 6
    • 84874800251 scopus 로고    scopus 로고
    • Electromagnetic relation of single measurement channel of MIT and computing of electro-magnetic parameters in measurement of brain conductivity
    • M. X. Qin, L. C. Jiao, S. J. Li, C. Wang, H. Lv and X. Z. Dong, "Electromagnetic relation of single measurement channel of MIT and computing of electro-magnetic parameters in measurement of brain conductivity," J. Fourth Mil. Med Univ, vol. 25, pp. 2172-2174, 2004.
    • (2004) J. Fourth Mil. Med Univ , vol.25 , pp. 2172-2174
    • Qin, M.X.1    Jiao, L.C.2    Li, S.J.3    Wang, C.4    Lv, H.5    Dong, X.Z.6
  • 7
    • 84900952641 scopus 로고    scopus 로고
    • Simulation calculation of forward problem of magnetic induction tomography based on FDTD
    • M. X. Qin, L. C. Jiao, H. Wang and H. Lv, "Simulation calculation of forward problem of magnetic induction tomography based on FDTD," Proc. IEEE Eng. Med. and Biol, pp.192-193, 2005.
    • (2005) Proc. IEEE Eng. Med. and Biol , pp. 192-193
    • Qin, M.X.1    Jiao, L.C.2    Wang, H.3    Lv, H.4
  • 8
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in frequency range 10 Hz to 20 GHz
    • S. Gabriel, R. W. Lau and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in frequency range 10 Hz to 20 GHz," Phys. Med. Biol, vol. 41, pp. 2251-2269, 1996.
    • (1996) Phys. Med. Biol , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 9
    • 0032051090 scopus 로고    scopus 로고
    • On modeling and personal dosimetry of cellular telephone helical antennas with the FDTD code
    • G. Lazzi, O. P. Gandhi, "On modeling and personal dosimetry of cellular telephone helical antennas with the FDTD code," IEEE Trans. Antennas Propagat, vol. 46, pp. 525-529, 1998.
    • (1998) IEEE Trans. Antennas Propagat , vol.46 , pp. 525-529
    • Lazzi, G.1    Gandhi, O.P.2
  • 10
    • 84900973205 scopus 로고    scopus 로고
    • D. Ge, Y. Yan, Finite difference time domain method in electromagnetic wave, (Xian: Publishing House of Xidian University), 2002.
    • D. Ge, Y. Yan, "Finite difference time domain method in electromagnetic wave," (Xian: Publishing House of Xidian University), 2002.
  • 11
    • 1842597605 scopus 로고    scopus 로고
    • Extension and validation of the equivalent sources helical antenna modeling with the FDTD code
    • G. Lazzi, Q. S. Yu and O. P. Gandhi, "Extension and validation of the equivalent sources helical antenna modeling with the FDTD code," Proc. IEEE Antennas and Prop. Society Inter. Sympocium, vol. 6, pp. 1054-1057, 1999.
    • (1999) Proc. IEEE Antennas and Prop. Society Inter. Sympocium , vol.6 , pp. 1054-1057
    • Lazzi, G.1    Yu, Q.S.2    Gandhi, O.P.3
  • 12
    • 0032988044 scopus 로고    scopus 로고
    • Magnetic induction tomography. - A measuring system for biological tissues
    • H. Griffiths, W. R. Stewart and W Gough, "Magnetic induction tomography. - A measuring system for biological tissues," Ann. N Y Acad. Sci, vol. 873, pp. 335-345, 1999.
    • (1999) Ann. N Y Acad. Sci , vol.873 , pp. 335-345
    • Griffiths, H.1    Stewart, W.R.2    Gough, W.3
  • 13
    • 0035111737 scopus 로고    scopus 로고
    • A numerical model for magnetic induction tomographic measurements in biological tissues
    • A. Morris, H. Griffiths and W. Gough, "A numerical model for magnetic induction tomographic measurements in biological tissues" Physiol. Meas. vol. 22, pp. 113-119, 2001.
    • (2001) Physiol. Meas , vol.22 , pp. 113-119
    • Morris, A.1    Griffiths, H.2    Gough, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.