메뉴 건너뛰기




Volumn 6, Issue 2, 2007, Pages 91-97

Quantitative Perfusion Imaging with Pulsed Arterial Spin Labeling: A phantom study

Author keywords

Arterial spin labeling; Cerebral blood flow; Flow phantom study; Q2TIPS; Quantitative blood flow measurement

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM PENTETATE;

EID: 35348821877     PISSN: 13473182     EISSN: 18802206     Source Type: Journal    
DOI: 10.2463/mrms.6.91     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 0026542167 scopus 로고
    • Magnetic resonance imaging of perfusion using spin inversion of arterial water
    • Williams DS, Detre JA, Leigh JS, Koretsky AP. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci USA 1992; 89:212-216.
    • (1992) Proc Natl Acad Sci , vol.89 , pp. 212-216
    • Williams, D.S.1    Detre, J.A.2    Leigh, J.S.3    Koretsky, A.P.4
  • 3
    • 0033854285 scopus 로고    scopus 로고
    • Imaging blood flow in brain tumors using arterial spin labeling
    • Silva AC, Kim SG, Garwood M. Imaging blood flow in brain tumors using arterial spin labeling. Magn Reson Med 2000; 44:169-173.
    • (2000) Magn Reson Med , vol.44 , pp. 169-173
    • Silva, A.C.1    Kim, S.G.2    Garwood, M.3
  • 4
    • 0033976957 scopus 로고    scopus 로고
    • Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
    • Alsop DC, Detre JA, Grossman M. Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging. Ann Neurol 2000; 47:93-100.
    • (2000) Ann Neurol , vol.47 , pp. 93-100
    • Alsop, D.C.1    Detre, J.A.2    Grossman, M.3
  • 5
    • 0034907799 scopus 로고    scopus 로고
    • Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging
    • Wolf RL, Alsop DC, Levy-Reis I, et al. Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging. AJNR Am J Neuroradiol 2001; 22:1334-1341.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1334-1341
    • Wolf, R.L.1    Alsop, D.C.2    Levy-Reis, I.3
  • 6
    • 0042844535 scopus 로고    scopus 로고
    • Quantifica-tion of blood flow in brain tumors: Comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging
    • Warmuth C, Gunther M, Zimmer C. Quantifica-tion of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging. Radiology 2003; 228:523-532.
    • (2003) Radiology , vol.228 , pp. 523-532
    • Warmuth, C.1    Gunther, M.2    Zimmer, C.3
  • 7
    • 0032997648 scopus 로고    scopus 로고
    • QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • Luh WM, Wong EC, Bandettini PA, Hyde JS. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999; 41:1246-1254.
    • (1999) Magn Reson Med , vol.41 , pp. 1246-1254
    • Luh, W.M.1    Wong, E.C.2    Bandettini, P.A.3    Hyde, J.S.4
  • 8
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • Wong EC, Buxton RB, Frank LR. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 1998; 39:702-708.
    • (1998) Magn Reson Med , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 9
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997; 10:237-249.
    • (1997) NMR Biomed , vol.10 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 11
    • 0026877346 scopus 로고
    • Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: Accounting for transit time and cross-relaxation
    • Zhang W, Williams DS, Detre JA, Koretsky AP. Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: accounting for transit time and cross-relaxation. Magn Reson Med 1992; 25:362-371.
    • (1992) Magn Reson Med , vol.25 , pp. 362-371
    • Zhang, W.1    Williams, D.S.2    Detre, J.A.3    Koretsky, A.P.4
  • 13
    • 0031727313 scopus 로고    scopus 로고
    • FAIR excluding radiation damping (FAIRER)
    • Zhou J, Mori S, van Zijl PC. FAIR excluding radiation damping (FAIRER). Magn Reson Med 1998; 40:712-719.
    • (1998) Magn Reson Med , vol.40 , pp. 712-719
    • Zhou, J.1    Mori, S.2    van Zijl, P.C.3
  • 14
    • 0033036192 scopus 로고    scopus 로고
    • Reperfu-sion in a gerbil model of forebrain ischemia using serial magnetic resonance FAIR perfusion imaging
    • Pell GS, Lythgoe MF, Thomas DL, et al. Reperfu-sion in a gerbil model of forebrain ischemia using serial magnetic resonance FAIR perfusion imaging. Stroke 1999; 30:1263-1270.
    • (1999) Stroke , vol.30 , pp. 1263-1270
    • Pell, G.S.1    Lythgoe, M.F.2    Thomas, D.L.3
  • 15
  • 16
    • 0033624185 scopus 로고    scopus 로고
    • 15O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans
    • 15O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans. Magn Reson Med 2000; 44:450-456.
    • (2000) Magn Reson Med , vol.44 , pp. 450-456
    • Ye, F.Q.1    Berman, K.F.2    Ellmore, T.3
  • 17
    • 0002420341 scopus 로고
    • Anatomy and freehand examination techniques
    • In: Newell DW, Aaslid R, eds, New York: Raven Press
    • Fujioka KA, Douville CM. Anatomy and freehand examination techniques, In: Newell DW, Aaslid R, eds. Transcranial Doppler. New York: Raven Press, 1992; 41-49.
    • (1992) Transcranial Doppler , pp. 41-49
    • Fujioka, K.A.1    Douville, C.M.2
  • 18
    • 0019421324 scopus 로고
    • Quantitative capillary topography and blood flow in the cerebral cortex of cats: An in vivo microscopic study
    • Pawlik G, Rackl A, Bing RJ. Quantitative capillary topography and blood flow in the cerebral cortex of cats: an in vivo microscopic study. Brain Res 1981; 208:35-58.
    • (1981) Brain Res , vol.208 , pp. 35-58
    • Pawlik, G.1    Rackl, A.2    Bing, R.J.3
  • 19
    • 0028830779 scopus 로고
    • Video microscopy of cerebrocortical capillary flow: Response to hypotension and intra-cranial hypertension
    • Hudetz AG, Feher G, Weigle CG, Knuese DE, Kampine JP. Video microscopy of cerebrocortical capillary flow: response to hypotension and intra-cranial hypertension. Am J Physiol 1995; 268: H2202-H2210.
    • (1995) Am J Physiol , vol.268
    • Hudetz, A.G.1    Feher, G.2    Weigle, C.G.3    Knuese, D.E.4    Kampine, J.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.