메뉴 건너뛰기




Volumn 39, Issue 2, 2007, Pages 71-74

Retrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO

Author keywords

Extracorporeal membrane oxygenation; Hollow fiber; Oxygenator; Silicone

Indexed keywords

SILICONE; POLYPROPYLENE; SILICONE DERIVATIVE;

EID: 35248882481     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (14)
  • 1
    • 33645953635 scopus 로고    scopus 로고
    • Survey of ECMO in the neonate after open heart surgery: Circuitry and team roles
    • Searles B, Gunst G, Terry B, et al. 2004 Survey of ECMO in the neonate after open heart surgery: Circuitry and team roles. J Extra Corpor Technol. 2005;37:351-4.
    • (2004) J Extra Corpor Technol. 2005 , vol.37 , pp. 351-354
    • Searles, B.1    Gunst, G.2    Terry, B.3
  • 2
    • 33645925307 scopus 로고    scopus 로고
    • Update on pediatric perfusion practice in North America: 2005 survey
    • Groom RC, Froebe S, Martin J, et al. Update on pediatric perfusion practice in North America: 2005 survey. J Extra Corpor Technol. 2005;37:343-50.
    • (2005) J Extra Corpor Technol , vol.37 , pp. 343-350
    • Groom, R.C.1    Froebe, S.2    Martin, J.3
  • 3
    • 1642267240 scopus 로고    scopus 로고
    • North American neonatal extracorporeal membrane oxygenation (ECMO) devices: 2002 survey results
    • Lawson DS, Walczak R, Lawson A, et al. North American neonatal extracorporeal membrane oxygenation (ECMO) devices: 2002 survey results. J Extra Corpor Technol. 2004;36:16-21.
    • (2004) J Extra Corpor Technol , vol.36 , pp. 16-21
    • Lawson, D.S.1    Walczak, R.2    Lawson, A.3
  • 4
    • 26844540119 scopus 로고    scopus 로고
    • Evaluation of a preprimed microporous hollow-fiber membrane for rapid response neonatal extracorporeal membrane oxygenation
    • Walczak R, Lawson DS, Kaemmer D, et al. Evaluation of a preprimed microporous hollow-fiber membrane for rapid response neonatal extracorporeal membrane oxygenation. Perfusion. 2005;20:269-75.
    • (2005) Perfusion , vol.20 , pp. 269-275
    • Walczak, R.1    Lawson, D.S.2    Kaemmer, D.3
  • 5
    • 0034072119 scopus 로고    scopus 로고
    • Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: A comparison between hollow fiber and flat sheet membrane oxygenators
    • Gu YJ, Boonstra PW, Graaff R, et al. Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: A comparison between hollow fiber and flat sheet membrane oxygenators. Artif Organs. 2000;24:43-8.
    • (2000) Artif Organs , vol.24 , pp. 43-48
    • Gu, Y.J.1    Boonstra, P.W.2    Graaff, R.3
  • 6
    • 0033369152 scopus 로고    scopus 로고
    • Quantitative evaluation of heparin-coated versus non-heparin coated bypass circuits during cardiopulmonary bypass
    • Stammers AH, Christensen KA, Lynch J, et al. Quantitative evaluation of heparin-coated versus non-heparin coated bypass circuits during cardiopulmonary bypass. J Extra Corpor Technol. 1999;31:135-41.
    • (1999) J Extra Corpor Technol , vol.31 , pp. 135-141
    • Stammers, A.H.1    Christensen, K.A.2    Lynch, J.3
  • 7
    • 0034007661 scopus 로고    scopus 로고
    • Clinical efficacy of heparin-bonded bypass circuits related to cytokine responses in children
    • Ozawa T, Yoshihara K, Koyama N, et al. Clinical efficacy of heparin-bonded bypass circuits related to cytokine responses in children. Ann Thorac Surg. 2000;69:584-90.
    • (2000) Ann Thorac Surg , vol.69 , pp. 584-590
    • Ozawa, T.1    Yoshihara, K.2    Koyama, N.3
  • 8
    • 32644482947 scopus 로고    scopus 로고
    • Phosphorylcholine coating may limit thrombin formation during high-risk cardiac surgery: A randomized controlled trial
    • Pappalardo F, Valle PD, Crescenzi G, et al. Phosphorylcholine coating may limit thrombin formation during high-risk cardiac surgery: A randomized controlled trial. Ann Thorac Surg. 2006;81:886-91.
    • (2006) Ann Thorac Surg , vol.81 , pp. 886-891
    • Pappalardo, F.1    Valle, P.D.2    Crescenzi, G.3
  • 9
    • 0034332701 scopus 로고    scopus 로고
    • Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
    • De Somer F, Francois K, van Oeveren W, et al. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. Eur J Cardiothorac Surg. 2000;18:602-6.
    • (2000) Eur J Cardiothorac Surg , vol.18 , pp. 602-606
    • De Somer, F.1    Francois, K.2    van Oeveren, W.3
  • 10
    • 0036147152 scopus 로고    scopus 로고
    • Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass
    • De Somer F, Van Belleghem Y, Caes F, et al. Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass. Perfusion. 2002;17:39-44.
    • (2002) Perfusion , vol.17 , pp. 39-44
    • De Somer, F.1    Van Belleghem, Y.2    Caes, F.3
  • 11
    • 0025495606 scopus 로고
    • Transfusion-induced immunomodulation and its clinical consequences
    • Blumberg N, Triulzi D, Heal J. Transfusion-induced immunomodulation and its clinical consequences. Transfus Med Rev. 1990;4(Suppl 1):24-35.
    • (1990) Transfus Med Rev , vol.4 , Issue.SUPPL. 1 , pp. 24-35
    • Blumberg, N.1    Triulzi, D.2    Heal, J.3
  • 12
    • 0026788319 scopus 로고
    • Homologous blood transfusion as a risk factor for postoperative infection after coronary artery bypass graft operations
    • Murphy PJ, Connery C, Hicks GL Jr, et al. Homologous blood transfusion as a risk factor for postoperative infection after coronary artery bypass graft operations. J Thorac Cardiovasc Surg. 1992;104:1092-9.
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 1092-1099
    • Murphy, P.J.1    Connery, C.2    Hicks Jr, G.L.3
  • 13
    • 4444363051 scopus 로고    scopus 로고
    • Blood conservation: Why bother?
    • Spiess BD. Blood conservation: Why bother? J Cardiothorac Vasc Anesth. 2004;18(4 Suppl):1S-5S.
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , Issue.4 SUPPL.
    • Spiess, B.D.1
  • 14
    • 22144453541 scopus 로고    scopus 로고
    • Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: A comparison with silicone membrane oxygenators
    • Khoshbin E, Westrope C, Pooboni S, et al. Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: A comparison with silicone membrane oxygenators. Perfusion. 2005;20:129-34.
    • (2005) Perfusion , vol.20 , pp. 129-134
    • Khoshbin, E.1    Westrope, C.2    Pooboni, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.