메뉴 건너뛰기




Volumn 52, Issue 3, 2007, Pages 193-197

An in vitro evaluation of the accuracy of Dentaport ZX apex locator in enlarged root canals

Author keywords

Electronic apex locator; File size; Irrigants; Root canal preparation; Root length determination

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS;

EID: 35248839561     PISSN: 00450421     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1834-7819.2007.tb00488.x     Document Type: Article
Times cited : (19)

References (37)
  • 1
    • 75449151475 scopus 로고
    • Factors affecting successful repair after root canal therapy
    • Seltzer S, Bender IB, Turkenkopf S. Factors affecting successful repair after root canal therapy. J Am Dent Assoc 1963;67:651-662.
    • (1963) J Am Dent Assoc , vol.67 , pp. 651-662
    • Seltzer, S.1    Bender, I.B.2    Turkenkopf, S.3
  • 2
    • 77049220185 scopus 로고
    • Microscopic investigation of root apexes
    • Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc 1955;50:544-552.
    • (1955) J Am Dent Assoc , vol.50 , pp. 544-552
    • Kuttler, Y.1
  • 3
    • 0002065098 scopus 로고
    • Cleaning and shaping the root canal length system
    • Cohen S, Burns RC, eds, 6th edn. St Louis: Mosby-Year Book Inc
    • West JD, Roane JB, Goerig AC. Cleaning and shaping the root canal length system. In: Cohen S, Burns RC, eds. Pathways of the Pulp. 6th edn. St Louis: Mosby-Year Book Inc., 1994:179-218.
    • (1994) Pathways of the Pulp , pp. 179-218
    • West, J.D.1    Roane, J.B.2    Goerig, A.C.3
  • 4
    • 0347025124 scopus 로고
    • Experimental study on iontophoresis
    • Suzuki K. Experimental study on iontophoresis. J Stomatol Soc (Japan) 1942;16:411-417.
    • (1942) J Stomatol Soc (Japan) , vol.16 , pp. 411-417
    • Suzuki, K.1
  • 5
    • 84886609551 scopus 로고
    • New method for measuring the length of the root canal
    • Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387.
    • (1962) J Dent Res , vol.41 , pp. 375-387
    • Sunada, I.1
  • 6
    • 0026845653 scopus 로고
    • The electronic determination of working length
    • McDonald NJ. The electronic determination of working length. Dent Clin North Am 1992;36:293-307.
    • (1992) Dent Clin North Am , vol.36 , pp. 293-307
    • McDonald, N.J.1
  • 7
    • 0028402339 scopus 로고
    • New electronic canal measuring device based on the ratio method
    • Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod 1994;20:111-114.
    • (1994) J Endod , vol.20 , pp. 111-114
    • Kobayashi, C.1    Suda, H.2
  • 8
    • 0031304075 scopus 로고    scopus 로고
    • A new engine-driven canal preparation system with electronic canal measuring capability
    • Kobayashi C, Yoshioka T, Suda H. A new engine-driven canal preparation system with electronic canal measuring capability. J Endod 1997;23:751-754.
    • (1997) J Endod , vol.23 , pp. 751-754
    • Kobayashi, C.1    Yoshioka, T.2    Suda, H.3
  • 9
    • 0024849016 scopus 로고
    • An in vitro comparison of five root canal length measuring instruments
    • Fouad AF, Krell KV. An in vitro comparison of five root canal length measuring instruments. J Endod 1989;15:573-577.
    • (1989) J Endod , vol.15 , pp. 573-577
    • Fouad, A.F.1    Krell, K.V.2
  • 10
    • 0025617602 scopus 로고
    • Electronic determination of root canal length by newly developed measuring device - influences of the diameter of apical foramen, the size of K-file and the root canal irrigants
    • Saito T, Yamashita Y. Electronic determination of root canal length by newly developed measuring device - influences of the diameter of apical foramen, the size of K-file and the root canal irrigants. Dent Jpn (Tokyo) 1990;27:65-72.
    • (1990) Dent Jpn (Tokyo) , vol.27 , pp. 65-72
    • Saito, T.1    Yamashita, Y.2
  • 11
    • 0027548645 scopus 로고
    • Accuracy of the Endex with variations in canal irrigants and foramen size
    • Fouad AF, Rivera EM, Krell KV. Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod 1993;19:63-67.
    • (1993) J Endod , vol.19 , pp. 63-67
    • Fouad, A.F.1    Rivera, E.M.2    Krell, K.V.3
  • 12
    • 0029397621 scopus 로고
    • In vitro evaluation of the accuracy of several electronic apex locators
    • Czerw RJ, Fulkerson MS, Donnelly JC, Walmann JO. In vitro evaluation of the accuracy of several electronic apex locators. J Endod 1995;21:572-575.
    • (1995) J Endod , vol.21 , pp. 572-575
    • Czerw, R.J.1    Fulkerson, M.S.2    Donnelly, J.C.3    Walmann, J.O.4
  • 13
    • 33749041279 scopus 로고    scopus 로고
    • Accuracy of three different electronic apex locators in detecting simulated horizontal and vertical root fractures
    • Ebrahim AK, Wadachi R, Suda H. Accuracy of three different electronic apex locators in detecting simulated horizontal and vertical root fractures. Aust Endod J 2006;32:64-69.
    • (2006) Aust Endod J , vol.32 , pp. 64-69
    • Ebrahim, A.K.1    Wadachi, R.2    Suda, H.3
  • 14
    • 0025493095 scopus 로고
    • A clinical evaluation of five electronic root canal length measuring instruments
    • Fouad AF, Krell KV, McKendry DJ, Koorbusch GF, Olson RA. A clinical evaluation of five electronic root canal length measuring instruments. J Endod 1990;16:446-449.
    • (1990) J Endod , vol.16 , pp. 446-449
    • Fouad, A.F.1    Krell, K.V.2    McKendry, D.J.3    Koorbusch, G.F.4    Olson, R.A.5
  • 15
    • 0025176371 scopus 로고
    • An evaluation of the apex locator Endocater
    • McDonald NJ, Hovland EJ. An evaluation of the apex locator Endocater. J Endod 1990;16:5-8.
    • (1990) J Endod , vol.16 , pp. 5-8
    • McDonald, N.J.1    Hovland, E.J.2
  • 16
    • 0027584335 scopus 로고
    • An in vivo evaluation of Endex electronic apex locator
    • Frank AL, Torabinejad M. An in vivo evaluation of Endex electronic apex locator. J Endod 1993;19:177-179.
    • (1993) J Endod , vol.19 , pp. 177-179
    • Frank, A.L.1    Torabinejad, M.2
  • 17
    • 0027700136 scopus 로고
    • In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator
    • Mayeda DL, Simon JHS, Aimar DF, Finley K. In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod 1993;19:545-548.
    • (1993) J Endod , vol.19 , pp. 545-548
    • Mayeda, D.L.1    Simon, J.H.S.2    Aimar, D.F.3    Finley, K.4
  • 18
    • 0028725401 scopus 로고
    • An in vivo comparative study of two apex locators
    • Pallarés A, Faus V. An in vivo comparative study of two apex locators. J Endod 1994;20:576-579.
    • (1994) J Endod , vol.20 , pp. 576-579
    • Pallarés, A.1    Faus, V.2
  • 19
    • 0030275701 scopus 로고    scopus 로고
    • An in vivo evaluation of Root ZX electronic apex locator
    • Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod 1996;22:616-618.
    • (1996) J Endod , vol.22 , pp. 616-618
    • Shabahang, S.1    Goon, W.W.2    Gluskin, A.H.3
  • 20
    • 0032086679 scopus 로고    scopus 로고
    • A SEM study of in vivo accuracy of the Root ZX electronic apex locator
    • Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 1998;24:438-441.
    • (1998) J Endod , vol.24 , pp. 438-441
    • Pagavino, G.1    Pace, R.2    Baccetti, T.3
  • 21
    • 0021414682 scopus 로고
    • Evaluation of the accuracy of the Neosono-D electronic apex locator
    • Berman LH, Fleischman SB. Evaluation of the accuracy of the Neosono-D electronic apex locator. J Endod 1984;10:164-167.
    • (1984) J Endod , vol.10 , pp. 164-167
    • Berman, L.H.1    Fleischman, S.B.2
  • 22
    • 0024743478 scopus 로고
    • Use of an electronic apex locator in the treatment of teeth with incomplete root formation
    • Hülsmann M, Pieper K. Use of an electronic apex locator in the treatment of teeth with incomplete root formation. Endod Dent Traumatol 1989;5:238-241.
    • (1989) Endod Dent Traumatol , vol.5 , pp. 238-241
    • Hülsmann, M.1    Pieper, K.2
  • 23
    • 33749512375 scopus 로고    scopus 로고
    • Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters
    • Ebrahim AK, Wadachi R, Suda H. Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters. Aust Dent J 2006;51:258-262.
    • (2006) Aust Dent J , vol.51 , pp. 258-262
    • Ebrahim, A.K.1    Wadachi, R.2    Suda, H.3
  • 24
    • 33745911926 scopus 로고    scopus 로고
    • The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: An in vitro study
    • Ebrahim AK, Yoshioka T, Kobayashi, Suda H. The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study. Aust Dent J 2006;51:153-157.
    • (2006) Aust Dent J , vol.51 , pp. 153-157
    • Ebrahim, A.K.1    Yoshioka, T.2    Kobayashi3    Suda, H.4
  • 25
    • 0030274468 scopus 로고    scopus 로고
    • Electronic length measurement using small and large files in enlarged canals
    • Nguyen HQ, Kaufman AY, Komorowski RC, Friedman S. Electronic length measurement using small and large files in enlarged canals. Int Endod J 1996;29:359-364.
    • (1996) Int Endod J , vol.29 , pp. 359-364
    • Nguyen, H.Q.1    Kaufman, A.Y.2    Komorowski, R.C.3    Friedman, S.4
  • 26
    • 0023285935 scopus 로고
    • An experimental study of the principle of electronic root canal measurement devices
    • Huang L. An experimental study of the principle of electronic root canal measurement devices. J Endod 1987;13:60-64.
    • (1987) J Endod , vol.13 , pp. 60-64
    • Huang, L.1
  • 27
    • 0020994545 scopus 로고
    • A model for demonstrating an electronic canal length measuring device
    • Aurelio JA, Nahmias Y, Gerstein H. A model for demonstrating an electronic canal length measuring device. J Endod 1983;9:568-569.
    • (1983) J Endod , vol.9 , pp. 568-569
    • Aurelio, J.A.1    Nahmias, Y.2    Gerstein, H.3
  • 28
    • 0028724947 scopus 로고
    • An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices
    • Czerw RJ, Fulkerson MS, Donnelly JC. An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 1994;20:605-606.
    • (1994) J Endod , vol.20 , pp. 605-606
    • Czerw, R.J.1    Fulkerson, M.S.2    Donnelly, J.C.3
  • 29
    • 0026176695 scopus 로고
    • A clinical evaluation of the Endocater - an electronic apex locator
    • Keller ME, Brown CE, Newton CW. A clinical evaluation of the Endocater - an electronic apex locator. J Endod 1991;17:271-274.
    • (1991) J Endod , vol.17 , pp. 271-274
    • Keller, M.E.1    Brown, C.E.2    Newton, C.W.3
  • 30
    • 0033088550 scopus 로고    scopus 로고
    • In vitro evaluation of the reliability of the Root ZX electronic apex locator
    • Ounsi HF, Naaman A. In vitro evaluation of the reliability of the Root ZX electronic apex locator. Int Endod J 1999;32:120-123.
    • (1999) Int Endod J , vol.32 , pp. 120-123
    • Ounsi, H.F.1    Naaman, A.2
  • 31
    • 33645103350 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three apex locators using glass tubules
    • Fan W, Fan B, Gutmann JL, Bian Z, Fan MW. Evaluation of the accuracy of three apex locators using glass tubules. Int Endod J 2006;39:127-135.
    • (2006) Int Endod J , vol.39 , pp. 127-135
    • Fan, W.1    Fan, B.2    Gutmann, J.L.3    Bian, Z.4    Fan, M.W.5
  • 32
    • 0032112589 scopus 로고    scopus 로고
    • Antimicrobial activity of 2.5% sodium hypochlorite and 0.2% chlorhexidine gluconate separately and combined, as endodontic irrigants
    • Kuruvilla JR, Kamath MP. Antimicrobial activity of 2.5% sodium hypochlorite and 0.2% chlorhexidine gluconate separately and combined, as endodontic irrigants. J Endod 1998;24:472-476.
    • (1998) J Endod , vol.24 , pp. 472-476
    • Kuruvilla, J.R.1    Kamath, M.P.2
  • 33
    • 0032133105 scopus 로고    scopus 로고
    • Chlorhexidine as a root canal medicament for treating inflammatory lesions in the periodontal space
    • Lindskog S, Pierce AM, Blomlöf L. Chlorhexidine as a root canal medicament for treating inflammatory lesions in the periodontal space. Endod Dent Traumatol 1998;14:186-190.
    • (1998) Endod Dent Traumatol , vol.14 , pp. 186-190
    • Lindskog, S.1    Pierce, A.M.2    Blomlöf, L.3
  • 34
    • 0033109224 scopus 로고    scopus 로고
    • Comparative effects of two endodontic irrigants, chlorhexidine digluconate and sodium hypochlorite, on macrophage adhesion to plastic surfaces
    • Segura JJ, Jiménez-Rubio A, Guerrero JM, Calvo JR. Comparative effects of two endodontic irrigants, chlorhexidine digluconate and sodium hypochlorite, on macrophage adhesion to plastic surfaces. J Endod 1999;25:243-246.
    • (1999) J Endod , vol.25 , pp. 243-246
    • Segura, J.J.1    Jiménez-Rubio, A.2    Guerrero, J.M.3    Calvo, J.R.4
  • 35
    • 0036484408 scopus 로고    scopus 로고
    • Accuracy of a new apex locator: An in vitro study
    • Kaufman AY, Keila S, Yoshpe M. Accuracy of a new apex locator: an in vitro study. Int Endod J 2002;35:186-192.
    • (2002) Int Endod J , vol.35 , pp. 186-192
    • Kaufman, A.Y.1    Keila, S.2    Yoshpe, M.3
  • 36
    • 0031297421 scopus 로고    scopus 로고
    • Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant
    • Pilot TF, Pitts DL. Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant. J Endod 1997;23:719-724.
    • (1997) J Endod , vol.23 , pp. 719-724
    • Pilot, T.F.1    Pitts, D.L.2
  • 37
    • 33745898640 scopus 로고
    • A study of the electronic method for measuring the root canal length - AC impedance of reamer tip in electrolyte
    • Waki H. A study of the electronic method for measuring the root canal length - AC impedance of reamer tip in electrolyte. Jpn J Conserv Dent 1981;24:115-131.
    • (1981) Jpn J Conserv Dent , vol.24 , pp. 115-131
    • Waki, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.