메뉴 건너뛰기




Volumn 26, Issue 3, 2007, Pages 738-746

Automated method for accurate abdominal fat quantification on water-saturated magnetic resonance images

Author keywords

Body composition; Fat quantification; Metabolic syndrome; Obesity; Visceral adipose tissue

Indexed keywords

ABDOMINAL FAT; ADULT; ARTICLE; AUTOMATION; BODY COMPOSITION; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; HISTOGRAM; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; ADIPOSE TISSUE; BODY WATER; CHEMISTRY; IMAGE PROCESSING; IMAGE QUALITY; METABOLISM; METHODOLOGY; PATHOLOGY; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING;

EID: 35248834737     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21040     Document Type: Article
Times cited : (29)

References (20)
  • 1
    • 0036681988 scopus 로고    scopus 로고
    • Obesity and the risk of heart failure
    • Kenchaiah S, Evans JC, Levy D, et al. Obesity and the risk of heart failure. N Engl J Med 2002;347:305-313.
    • (2002) N Engl J Med , vol.347 , pp. 305-313
    • Kenchaiah, S.1    Evans, J.C.2    Levy, D.3
  • 2
    • 0037048167 scopus 로고    scopus 로고
    • Overweight and obesity as determinants of cardiovascular risk: The Framingham experience
    • Wilson PW, D'Agostino RB, Sullivan L, Parise H, Kannel WB. Overweight and obesity as determinants of cardiovascular risk: the Framingham experience. Arch Intern Med 2002;162:1867-1872.
    • (2002) Arch Intern Med , vol.162 , pp. 1867-1872
    • Wilson, P.W.1    D'Agostino, R.B.2    Sullivan, L.3    Parise, H.4    Kannel, W.B.5
  • 3
    • 18744412152 scopus 로고    scopus 로고
    • Obesity, hypertension and insulin resistance
    • Sharma AM, Chetty VT. Obesity, hypertension and insulin resistance. Acta Diabetol 2005;42(Suppl 1):S3-S8.
    • (2005) Acta Diabetol , vol.42 , Issue.SUPPL. 1
    • Sharma, A.M.1    Chetty, V.T.2
  • 5
    • 23744458765 scopus 로고    scopus 로고
    • Imaging of visceral adipose tissue: An emerging diagnostic tool and therapeutic target
    • Iacobellis G. Imaging of visceral adipose tissue: an emerging diagnostic tool and therapeutic target. Curr Drug Targets Cardiovasc Haematol Disord 2005;5:345-353.
    • (2005) Curr Drug Targets Cardiovasc Haematol Disord , vol.5 , pp. 345-353
    • Iacobellis, G.1
  • 6
    • 0034116222 scopus 로고    scopus 로고
    • Human body composition: In vivo methods
    • Ellis KJ. Human body composition: in vivo methods. Physiol Rev 2000;80:649-680.
    • (2000) Physiol Rev , vol.80 , pp. 649-680
    • Ellis, K.J.1
  • 7
    • 0142209266 scopus 로고    scopus 로고
    • Advances in the application of imaging methods in applied and clinical physiology
    • Ross R. Advances in the application of imaging methods in applied and clinical physiology. Acta Diabetol 2003;40(Suppl 1):S45-S50.
    • (2003) Acta Diabetol , vol.40 , Issue.SUPPL. 1
    • Ross, R.1
  • 8
    • 0024348435 scopus 로고
    • Measurement of fat distribution by magnetic resonance imaging
    • Staten MA, Totty WG, Kohrt WM. Measurement of fat distribution by magnetic resonance imaging. Invest Radiol 1989;24:345-349.
    • (1989) Invest Radiol , vol.24 , pp. 345-349
    • Staten, M.A.1    Totty, W.G.2    Kohrt, W.M.3
  • 9
    • 14044258733 scopus 로고    scopus 로고
    • Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification
    • Peng Q, McColl RW, Wang J, Chia JM, Weatherall PT. Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification. J Magn Reson Imaging 2005;21:263-271.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 263-271
    • Peng, Q.1    McColl, R.W.2    Wang, J.3    Chia, J.M.4    Weatherall, P.T.5
  • 13
    • 0028064850 scopus 로고
    • Imaging techniques for the assessment of body composition
    • Fuller MF, Fowler PA, McNeill G, Foster MA. Imaging techniques for the assessment of body composition. J Nutr 1994;124(Suppl 8):1546S-1550S.
    • (1994) J Nutr , vol.124 , Issue.SUPPL. 8
    • Fuller, M.F.1    Fowler, P.A.2    McNeill, G.3    Foster, M.A.4
  • 14
    • 0022573365 scopus 로고
    • Accuracy of area measurements made from MR images compared with computed-tomography
    • Zhu XP, Checkley DR, Hickey DS, Isherwood I. Accuracy of area measurements made from MR images compared with computed-tomography. J Comput Assist Tomogr 1986;10:96-102.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 96-102
    • Zhu, X.P.1    Checkley, D.R.2    Hickey, D.S.3    Isherwood, I.4
  • 15
    • 0022369129 scopus 로고
    • Truncation artifacts in magnetic resonance imaging
    • Wood ML, Henkelman RM. Truncation artifacts in magnetic resonance imaging. Magn Reson Med 1985;2:517-526.
    • (1985) Magn Reson Med , vol.2 , pp. 517-526
    • Wood, M.L.1    Henkelman, R.M.2
  • 16
  • 17
    • 4544369064 scopus 로고    scopus 로고
    • MRI intensity inhomogeneity correction by combining intensity and spatial information
    • Vovk U, Pernus F, Likar B. MRI intensity inhomogeneity correction by combining intensity and spatial information. Phys Med Biol 2004;49:4119-4133.
    • (2004) Phys Med Biol , vol.49 , pp. 4119-4133
    • Vovk, U.1    Pernus, F.2    Likar, B.3
  • 18
    • 31744442025 scopus 로고    scopus 로고
    • Intensity non-uniformity correction in MRI: Existing methods and their validation
    • Belaroussi B, Milles J, Carme S, Zhu YM, Benoit-Cattin H. Intensity non-uniformity correction in MRI: existing methods and their validation. Med Image Anal 2006;10:234-246.
    • (2006) Med Image Anal , vol.10 , pp. 234-246
    • Belaroussi, B.1    Milles, J.2    Carme, S.3    Zhu, Y.M.4    Benoit-Cattin, H.5
  • 19
    • 1942470559 scopus 로고    scopus 로고
    • Quantification of intra-abdominal fat during controlled weight reduction: Assessment using the water-suppressed breath-hold MRI technique
    • Tintera J, Harantova P, Suchanek P, et al. Quantification of intra-abdominal fat during controlled weight reduction: assessment using the water-suppressed breath-hold MRI technique. Physiol Res 2004;53:229-234.
    • (2004) Physiol Res , vol.53 , pp. 229-234
    • Tintera, J.1    Harantova, P.2    Suchanek, P.3
  • 20
    • 33646201989 scopus 로고    scopus 로고
    • Accurate quantification of visceral adipose tissue (VAT) using water-saturation MRI and computer segmentation: Preliminary results
    • Armao D, Guyon JP, Firat Z, Brown MA, Semelka RC. Accurate quantification of visceral adipose tissue (VAT) using water-saturation MRI and computer segmentation: preliminary results. J Magn Reson Imaging 2006;23:736-741.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 736-741
    • Armao, D.1    Guyon, J.P.2    Firat, Z.3    Brown, M.A.4    Semelka, R.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.