메뉴 건너뛰기




Volumn 6510, Issue PART 2, 2007, Pages

Clinical usefulness of automatic phase selection in coronary CT angiography (CTA)

Author keywords

Coronary CT angiography (CTA); Multislice computed tomography (MSCT); Optimal cardiac phase selection

Indexed keywords

ALGORITHMS; COMPUTERIZED TOMOGRAPHY; IMAGE ACQUISITION; IMAGE QUALITY; PATIENT MONITORING;

EID: 35148861259     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.707265     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • K. Taguchi and H. Anno, "High temporal resolution for multislice helical computed tomography," Med Phys. 27(5), 861-872 (2000).
    • (2000) Med Phys , vol.27 , Issue.5 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 2
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • M. Kachelriess, S. Ulzheimer and WA. Kalender, "ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart," Med Phys. 27(8), 1881-1902 (2000).
    • (2000) Med Phys , vol.27 , Issue.8 , pp. 1881-1902
    • Kachelriess, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 3
    • 31144447047 scopus 로고    scopus 로고
    • Usefulness of multidetector row spiral computed tomography with 64- × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses
    • D. Ropers, J. Rixe, K. Anders, A. Kuttner, U. Baum, W. Bautz, WG. Daniel and S. Achenbach, "Usefulness of multidetector row spiral computed tomography with 64- × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses," Am J Cardiol. 97(3), 343-348 (2006).
    • (2006) Am J Cardiol , vol.97 , Issue.3 , pp. 343-348
    • Ropers, D.1    Rixe, J.2    Anders, K.3    Kuttner, A.4    Baum, U.5    Bautz, W.6    Daniel, W.G.7    Achenbach, S.8
  • 4
    • 0033876932 scopus 로고    scopus 로고
    • In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    • S. Achenbach, D. Ropers, J. Holle, G. Muschiol, WG. Daniel and W. Moshage, "In-plane coronary arterial motion velocity: measurement with electron-beam CT," Radiology. 216(2), 457-463 (2000).
    • (2000) Radiology , vol.216 , Issue.2 , pp. 457-463
    • Achenbach, S.1    Ropers, D.2    Holle, J.3    Muschiol, G.4    Daniel, W.G.5    Moshage, W.6
  • 5
    • 0038372103 scopus 로고    scopus 로고
    • A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT
    • M. Vembar, MJ. Garcia, DJ. Heuscher, R. Haberl, D. Matthews, GE. Böhme and NL. Greenberg, "A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT," Med Phys. 30(7), 1683-1693 (2003).
    • (2003) Med Phys , vol.30 , Issue.7 , pp. 1683-1693
    • Vembar, M.1    Garcia, M.J.2    Heuscher, D.J.3    Haberl, R.4    Matthews, D.5    Böhme, G.E.6    Greenberg, N.L.7
  • 6
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality
    • C. Hong, CR. Becker, A. Huber, UJ. Schoepf, B. Ohnesorge, A. Knez, R. Bruning and MF. Reiser, "ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality," Radiology. 220(3), 712-717 (2001).
    • (2001) Radiology , vol.220 , Issue.3 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3    Schoepf, U.J.4    Ohnesorge, B.5    Knez, A.6    Bruning, R.7    Reiser, M.F.8
  • 7
    • 0035191747 scopus 로고    scopus 로고
    • Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    • AF. Kopp, S. Schroeder, A. Kuettner, M. Heuschmid, C. Georg, B. Ohnesorge, R. Kuzo and CD. Claussen, "Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window," Radiology. 221(3), 683-688 (2001).
    • (2001) Radiology , vol.221 , Issue.3 , pp. 683-688
    • Kopp, A.F.1    Schroeder, S.2    Kuettner, A.3    Heuschmid, M.4    Georg, C.5    Ohnesorge, B.6    Kuzo, R.7    Claussen, C.D.8
  • 9
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • M. Kachelriess, DA. Sennst, W. Maxlmoser and WA. Kalender, "Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart," Med Phys. 29(7), 1489-1503 (2002).
    • (2002) Med Phys , vol.29 , Issue.7 , pp. 1489-1503
    • Kachelriess, M.1    Sennst, D.A.2    Maxlmoser, W.3    Kalender, W.A.4
  • 10
    • 4444324085 scopus 로고    scopus 로고
    • Automatic phase determination for retrospectively gated cardiac CT
    • R. Manzke, T. Köhler, T. Nielsen, D. Hawkes and M. Grass, "Automatic phase determination for retrospectively gated cardiac CT," Med Phys. 31(12), 3345-3362 (2004).
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3345-3362
    • Manzke, R.1    Köhler, T.2    Nielsen, T.3    Hawkes, D.4    Grass, M.5
  • 11
    • 33745868752 scopus 로고    scopus 로고
    • Aperture weighted cardiac reconstruction for cone-beam CT
    • P. Koken and M. Grass, "Aperture weighted cardiac reconstruction for cone-beam CT," Phys Med Biol. 51(14), 3433-3448 (2006).
    • (2006) Phys Med Biol , vol.51 , Issue.14 , pp. 3433-3448
    • Koken, P.1    Grass, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.