Comparison of anterior vitrectorhexis and continuous curvilinear capsulorhexis in pediatric cataract and intraocular lens implantation surgery: A 10-year analysis

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ANALYSIS; ANTERIOR CAPSULE TEAR; ANTERIOR VITRECTORHEXIS; ARTICLE; CAPSULORHEXIS; CAPSULOTOMY; CATARACT; CATARACT EXTRACTION; CHILD; COMPARATIVE STUDY; CONTINUOUS CURVILINEAR CAPSULORHEXIS; CONTROLLED STUDY; DISSECTION; EYE; HUMAN; LACRIMAL FLUID; LENS CAPSULE; LENS DISEASE; LENS IMPLANTATION; MAJOR CLINICAL STUDY; MANIPULATIVE MEDICINE; MEDICAL RECORD REVIEW; PEDIATRICS; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RISK FACTOR;

EID: 35148817926     PISSN: 10918531     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jaapos.2007.03.012     Document Type: Article
Times cited : (34)

References (8)
  • 1
    • 17244366352 scopus 로고    scopus 로고
    • Anterior lens capsule management in pediatric cataract surgery
    • Wilson Jr. M.E. Anterior lens capsule management in pediatric cataract surgery. Trans Am Ophthalmol Soc 102 (2004) 391-422
    • (2004) Trans Am Ophthalmol Soc , vol.102 , pp. 391-422
    • Wilson Jr., M.E.1
  • 2
    • 0033372027 scopus 로고    scopus 로고
    • Anterior capsule management for pediatric intraocular lens implantation
    • Wilson M.E. Anterior capsule management for pediatric intraocular lens implantation. J Pediatr Ophthalmol Strabismus 36 (1999) 314-319
    • (1999) J Pediatr Ophthalmol Strabismus , vol.36 , pp. 314-319
    • Wilson, M.E.1
  • 3
    • 0027971707 scopus 로고
    • Comparison of mechanized anterior capsulectomy and manual continuous capsulorhexis in pediatric eyes
    • Wilson M.E., Bluestein E.C., Wang X.H., and Apple D.J. Comparison of mechanized anterior capsulectomy and manual continuous capsulorhexis in pediatric eyes. J Cataract Refract Surg 20 (1994) 602-606
    • (1994) J Cataract Refract Surg , vol.20 , pp. 602-606
    • Wilson, M.E.1    Bluestein, E.C.2    Wang, X.H.3    Apple, D.J.4
  • 4
    • 0032910843 scopus 로고    scopus 로고
    • Elastic properties and scanning electron microscopic appearance of manual continuous curvilinear capsulorhexis and vitrectorhexis in an animal model of pediatric cataract
    • Andreo L.K., Wilson M.E., and Apple D.J. Elastic properties and scanning electron microscopic appearance of manual continuous curvilinear capsulorhexis and vitrectorhexis in an animal model of pediatric cataract. J Cataract Refract Surg 25 (1999) 534-539
    • (1999) J Cataract Refract Surg , vol.25 , pp. 534-539
    • Andreo, L.K.1    Wilson, M.E.2    Apple, D.J.3
  • 5
    • 0019843932 scopus 로고
    • Choice of surgical technique in the management of congenital cataract
    • Taylor D.S.I. Choice of surgical technique in the management of congenital cataract. Trans Ophthalmol Soc UK 101 (1981) 114-117
    • (1981) Trans Ophthalmol Soc UK , vol.101 , pp. 114-117
    • Taylor, D.S.I.1
  • 6
    • 0029890462 scopus 로고    scopus 로고
    • Mechanized anterior capsulectomy as an alternative to manual capsulorhexis in children undergoing intraocular lens implantation
    • Wilson M.E., Saunders R.A., Roberts E.L., and Apple D.J. Mechanized anterior capsulectomy as an alternative to manual capsulorhexis in children undergoing intraocular lens implantation. J Pediatr Ophthalmol Strabismus 33 (1996) 237-240
    • (1996) J Pediatr Ophthalmol Strabismus , vol.33 , pp. 237-240
    • Wilson, M.E.1    Saunders, R.A.2    Roberts, E.L.3    Apple, D.J.4
  • 7
    • 33745965153 scopus 로고    scopus 로고
    • Extensibility and scanning electron microscopy evaluation of 5 pediatric anterior capsulotomy techniques in a porcine model
    • Trivedi R.H., Wilson M.E., and Bartholomew L.R. Extensibility and scanning electron microscopy evaluation of 5 pediatric anterior capsulotomy techniques in a porcine model. J Cataract Refract Surg 32 (2006) 1206-1213
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1206-1213
    • Trivedi, R.H.1    Wilson, M.E.2    Bartholomew, L.R.3