1
-
-
0023750601
-
Computed electroencephalographic topographic brain mapping. A new and accurate monitor of cerebral circulation and function for patients having carotid endarterectomy
-
Ahn S.S., Jordan S.E., Nuwer M.R., Marcus D.R., and Moore W.S. Computed electroencephalographic topographic brain mapping. A new and accurate monitor of cerebral circulation and function for patients having carotid endarterectomy. J Vasc Surg 8 3 (1988) 247-254
-
(1988)
J Vasc Surg
, vol.8
, Issue.3
, pp. 247-254
-
-
Ahn, S.S.1
Jordan, S.E.2
Nuwer, M.R.3
Marcus, D.R.4
Moore, W.S.5
-
2
-
-
27544505171
-
Electroencephalographic background desynchronization during cerebral blood flow reduction
-
Cursi M., Meraviglia M.V., Fanelli G.F., Chiesa R., Tirelli A., Comi G., et al. Electroencephalographic background desynchronization during cerebral blood flow reduction. Clin Neurophysiol 116 11 (2005) 2577-2585
-
(2005)
Clin Neurophysiol
, vol.116
, Issue.11
, pp. 2577-2585
-
-
Cursi, M.1
Meraviglia, M.V.2
Fanelli, G.F.3
Chiesa, R.4
Tirelli, A.5
Comi, G.6
-
3
-
-
0026719707
-
EEG power changes are more sensitive than spectral edge frequency variation for detection of cerebral ischemia during carotid artery surgery: a prospective assessment of processed EEG monitoring
-
Hanowell L., Soriano S., and Bennett H. EEG power changes are more sensitive than spectral edge frequency variation for detection of cerebral ischemia during carotid artery surgery: a prospective assessment of processed EEG monitoring. J Cardiothorac Vasc Anesth 6 3 (1992) 292-294
-
(1992)
J Cardiothorac Vasc Anesth
, vol.6
, Issue.3
, pp. 292-294
-
-
Hanowell, L.1
Soriano, S.2
Bennett, H.3
-
4
-
-
0030939234
-
Continuous electroencephalographic monitoring and selective shunting reduces neurologic morbidity rates in carotid endarterectomy
-
Konstadinos A., Loubser P., Mizrahi E., Kantis G., Jiang Z.D., and Howell J. Continuous electroencephalographic monitoring and selective shunting reduces neurologic morbidity rates in carotid endarterectomy. J Vasc Surg 25 (1997) 620-628
-
(1997)
J Vasc Surg
, vol.25
, pp. 620-628
-
-
Konstadinos, A.1
Loubser, P.2
Mizrahi, E.3
Kantis, G.4
Jiang, Z.D.5
Howell, J.6
-
5
-
-
0035192701
-
EEG evidence for shunt requirement during carotid endarterectomy: optimal EEG derivations with respect to frequency bands and anesthetic regimen
-
Laman D.M., van der Reijden C.S., Wieneke G.H., van Duijn H., and van Huffelen A.C. EEG evidence for shunt requirement during carotid endarterectomy: optimal EEG derivations with respect to frequency bands and anesthetic regimen. J Clin Neurophysiol 18 4 (2001) 353-363
-
(2001)
J Clin Neurophysiol
, vol.18
, Issue.4
, pp. 353-363
-
-
Laman, D.M.1
van der Reijden, C.S.2
Wieneke, G.H.3
van Duijn, H.4
van Huffelen, A.C.5
-
6
-
-
23844481097
-
QEEG changes during carotid clamping in carotid endarterectomy: spectral edge frequency parameters and relative band power parameters
-
Laman D.M., Wieneke G.H., van Duijn H., Veldhuizen R.J., and van Huffelen A.C. QEEG changes during carotid clamping in carotid endarterectomy: spectral edge frequency parameters and relative band power parameters. J Clin Neurophysiol 22 4 (2005) 244-252
-
(2005)
J Clin Neurophysiol
, vol.22
, Issue.4
, pp. 244-252
-
-
Laman, D.M.1
Wieneke, G.H.2
van Duijn, H.3
Veldhuizen, R.J.4
van Huffelen, A.C.5
-
8
-
-
0023830609
-
Continuous electroencephalographic monitoring during carotid endarterectomy
-
McFarland H., Pinkerton J., and Frye D. Continuous electroencephalographic monitoring during carotid endarterectomy. J Cardiovasc Surg 29 (1988) 12-18
-
(1988)
J Cardiovasc Surg
, vol.29
, pp. 12-18
-
-
McFarland, H.1
Pinkerton, J.2
Frye, D.3
-
9
-
-
0033953892
-
Computer-assisted EEG monitoring during carotid endarterectomy
-
Minicucci F., Cursi M., Fornara C., Rizzo C., Tirelli R.C., Fannelli G., et al. Computer-assisted EEG monitoring during carotid endarterectomy. J Clin Neurophysiol 17 1 (2000) 101-107
-
(2000)
J Clin Neurophysiol
, vol.17
, Issue.1
, pp. 101-107
-
-
Minicucci, F.1
Cursi, M.2
Fornara, C.3
Rizzo, C.4
Tirelli, R.C.5
Fannelli, G.6
-
12
-
-
33751249917
-
Extended BSI for continuous EEG monitoring in carotid endarterectomy
-
van Putten M.J.A.M. Extended BSI for continuous EEG monitoring in carotid endarterectomy. Clin Neurophysiol 117 (2006) 2661-2666
-
(2006)
Clin Neurophysiol
, vol.117
, pp. 2661-2666
-
-
van Putten, M.J.A.M.1
-
13
-
-
7644222003
-
Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index
-
van Putten M.J.A.M., and Tavy D.L.J. Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index. Stroke 35 11 (2004) 2489-2492
-
(2004)
Stroke
, vol.35
, Issue.11
, pp. 2489-2492
-
-
van Putten, M.J.A.M.1
Tavy, D.L.J.2
-
14
-
-
1842559903
-
A brain symmetry index (BSI) for online EEG monitoring in carotid endarterectomy
-
van Putten M.J.A.M., Peters J.M., Mulder S.M., de Haas J.A.M., Bruijninckx C.M.A., and Tavy D.L.J. A brain symmetry index (BSI) for online EEG monitoring in carotid endarterectomy. Clin Neurophysiol 115 5 (2004) 1189-1194
-
(2004)
Clin Neurophysiol
, vol.115
, Issue.5
, pp. 1189-1194
-
-
van Putten, M.J.A.M.1
Peters, J.M.2
Mulder, S.M.3
de Haas, J.A.M.4
Bruijninckx, C.M.A.5
Tavy, D.L.J.6
-
15
-
-
24644444651
-
Detecting temporal lobe seizures from scalp EEG recordings: a comparison of various features
-
van Putten M.J.A.M., Kind T., Visser F., and Lagerburg V. Detecting temporal lobe seizures from scalp EEG recordings: a comparison of various features. Clin Neurophysiol 116 10 (2005) 2480-2489
-
(2005)
Clin Neurophysiol
, vol.116
, Issue.10
, pp. 2480-2489
-
-
van Putten, M.J.A.M.1
Kind, T.2
Visser, F.3
Lagerburg, V.4
-
16
-
-
17644421457
-
Unilateral or asymmetric localization of lambda waves is not a pathologic finding
-
Weber P. Unilateral or asymmetric localization of lambda waves is not a pathologic finding. J Child Neurol 20 3 (2005) 250-251
-
(2005)
J Child Neurol
, vol.20
, Issue.3
, pp. 250-251
-
-
Weber, P.1
|