메뉴 건너뛰기




Volumn 22, Issue 7 SUPPL., 2007, Pages 6-11

Principles of a Clean Operating Room Environment

Author keywords

arthroplasty; clean operating room; infection

Indexed keywords

AIR; ARTHROPLASTY; HAND WASHING; HEALTH CARE PERSONNEL; HUMAN; MEDICAL LITERATURE; OPERATING ROOM; ORTHOPEDIC SURGERY; PRACTICE GUIDELINE; REVIEW; SURGEON; SURGICAL APPROACH; SURGICAL EQUIPMENT; SURGICAL GLOVE; SURGICAL INFECTION; SURGICAL INSTRUMENT; SURGICAL MASK; ULTRAVIOLET RADIATION;

EID: 34848893557     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2007.05.013     Document Type: Review
Times cited : (37)

References (43)
  • 1
    • 0021086338 scopus 로고
    • Airborne contamination of wounds in joint replacement operations: the relationship to sepsis rates
    • Lidwell O.M., Lowbury E.J., Whyte W., et al. Airborne contamination of wounds in joint replacement operations: the relationship to sepsis rates. J Hosp Infect 4 (1983) 111
    • (1983) J Hosp Infect , vol.4 , pp. 111
    • Lidwell, O.M.1    Lowbury, E.J.2    Whyte, W.3
  • 2
    • 0032801791 scopus 로고    scopus 로고
    • Deterioration of theatre discipline during total joint replacement-have theatre protocols been abandoned?
    • Madhavan P., Blom A., Karagkevrakis B., et al. Deterioration of theatre discipline during total joint replacement-have theatre protocols been abandoned?. Ann R Coll Surg Engl 81 (1999) 262
    • (1999) Ann R Coll Surg Engl , vol.81 , pp. 262
    • Madhavan, P.1    Blom, A.2    Karagkevrakis, B.3
  • 3
    • 0016758063 scopus 로고
    • The operating room environment as affected by people and the surgical face mask
    • Ritter M.A., Eitzen H., French M.L., et al. The operating room environment as affected by people and the surgical face mask. Clin Orthop Relat Res 111 (1975) 147
    • (1975) Clin Orthop Relat Res , vol.111 , pp. 147
    • Ritter, M.A.1    Eitzen, H.2    French, M.L.3
  • 5
    • 0001047966 scopus 로고
    • Dispersal of bacteria on desquamated skin
    • Davies R.R., and Noble W.C. Dispersal of bacteria on desquamated skin. Lancet 2 (1962) 1295
    • (1962) Lancet , vol.2 , pp. 1295
    • Davies, R.R.1    Noble, W.C.2
  • 6
    • 0015804591 scopus 로고
    • The airborne component of wound contamination and infection
    • Walter C.W., and Kundsin R.B. The airborne component of wound contamination and infection. Arch Surg 107 (1973) 588
    • (1973) Arch Surg , vol.107 , pp. 588
    • Walter, C.W.1    Kundsin, R.B.2
  • 7
    • 0014575655 scopus 로고
    • Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint. With special reference to the bacterial content of the air of the operating room
    • Charnley J., and Eftekhar N. Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint. With special reference to the bacterial content of the air of the operating room. Br J Surg 56 (1969) 641
    • (1969) Br J Surg , vol.56 , pp. 641
    • Charnley, J.1    Eftekhar, N.2
  • 8
    • 0019983329 scopus 로고
    • Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study
    • Lidwell O.M., Lowbury E.J., Whyte W., et al. Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. Br Med J (Clin Res Ed) 285 (1982) 10
    • (1982) Br Med J (Clin Res Ed) , vol.285 , pp. 10
    • Lidwell, O.M.1    Lowbury, E.J.2    Whyte, W.3
  • 10
    • 0023127628 scopus 로고
    • Infection rate in total hip arthroplasty as a function of air cleanliness and antibiotic prophylaxis. 10-year experience with 2,384 cementless Lord madreporic prostheses.
    • Marotte J.H., Lord G.A., Blanchard J.P., et al. Infection rate in total hip arthroplasty as a function of air cleanliness and antibiotic prophylaxis. 10-year experience with 2,384 cementless Lord madreporic prostheses. J Arthroplasty 2 (1987) 77
    • (1987) J Arthroplasty , vol.2 , pp. 77
    • Marotte, J.H.1    Lord, G.A.2    Blanchard, J.P.3
  • 11
    • 0032788854 scopus 로고    scopus 로고
    • Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination
    • Friberg B., Friberg S., and Burman L.G. Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination. J Hosp Infect 42 (1999) 287
    • (1999) J Hosp Infect , vol.42 , pp. 287
    • Friberg, B.1    Friberg, S.2    Burman, L.G.3
  • 12
    • 0020071031 scopus 로고
    • Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system
    • Salvati E.A., Robinson R.P., Zeno S.M., et al. Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system. J Bone Joint Surg Am 64 (1982) 525
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 525
    • Salvati, E.A.1    Robinson, R.P.2    Zeno, S.M.3
  • 13
    • 0025822570 scopus 로고
    • Ultraviolet radiation compared to an ultra-clean air enclosure. Comparison of air bacteria counts in operating rooms
    • Berg M., Bergman B.R., and Hoborn J. Ultraviolet radiation compared to an ultra-clean air enclosure. Comparison of air bacteria counts in operating rooms. J Bone Joint Surg Br 73 (1991) 811
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 811
    • Berg, M.1    Bergman, B.R.2    Hoborn, J.3
  • 15
    • 0027058336 scopus 로고
    • Ultraviolet radiation and ultra-clean air enclosures in operating rooms. UV-protection, economy, and comfort
    • Berg-Perier M., Cederblad A., and Persson U. Ultraviolet radiation and ultra-clean air enclosures in operating rooms. UV-protection, economy, and comfort. J Arthroplasty 7 (1992) 457
    • (1992) J Arthroplasty , vol.7 , pp. 457
    • Berg-Perier, M.1    Cederblad, A.2    Persson, U.3
  • 16
    • 0029839548 scopus 로고    scopus 로고
    • Optimisation of ultraclean air. The role of instrument preparation
    • Chosky S.A., Modha D., and Taylor G.J. Optimisation of ultraclean air. The role of instrument preparation. J Bone Joint Surg Br 78 (1996) 835
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 835
    • Chosky, S.A.1    Modha, D.2    Taylor, G.J.3
  • 17
    • 0030058639 scopus 로고    scopus 로고
    • Air contamination during skin preparation and draping in joint replacement surgery
    • Brown A.R., Taylor G.J., and Gregg P.J. Air contamination during skin preparation and draping in joint replacement surgery. J Bone Joint Surg Br 78 (1996) 92
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 92
    • Brown, A.R.1    Taylor, G.J.2    Gregg, P.J.3
  • 18
    • 0023088274 scopus 로고
    • Rate of bacterial recolonization of the skin after preparation: four methods compared
    • Johnston D.H., Fairclough J.A., Brown E.M., et al. Rate of bacterial recolonization of the skin after preparation: four methods compared. Br J Surg 74 (1987) 64
    • (1987) Br J Surg , vol.74 , pp. 64
    • Johnston, D.H.1    Fairclough, J.A.2    Brown, E.M.3
  • 19
    • 0025162278 scopus 로고
    • Comparison of a one-step iodophor skin preparation versus traditional preparation in total joint surgery
    • Gilliam D.L., and Nelson C.L. Comparison of a one-step iodophor skin preparation versus traditional preparation in total joint surgery. Clin Orthop Relat Res 250 (1990) 258
    • (1990) Clin Orthop Relat Res , vol.250 , pp. 258
    • Gilliam, D.L.1    Nelson, C.L.2
  • 20
    • 0018933986 scopus 로고
    • The antimicrobial effectiveness of operative-site preparative agents: a microbiological and clinical study
    • Ritter M.A., French M.L., Eitzen H.E., et al. The antimicrobial effectiveness of operative-site preparative agents: a microbiological and clinical study. J Bone Joint Surg Am 62 (1980) 826
    • (1980) J Bone Joint Surg Am , vol.62 , pp. 826
    • Ritter, M.A.1    French, M.L.2    Eitzen, H.E.3
  • 21
    • 0017073139 scopus 로고
    • The plastic surgical adhesive drape: an evaluation of its efficacy as a microbial barrier
    • French M.L., Eitzen H.E., and Ritter M.A. The plastic surgical adhesive drape: an evaluation of its efficacy as a microbial barrier. Ann Surg 184 (1976) 46
    • (1976) Ann Surg , vol.184 , pp. 46
    • French, M.L.1    Eitzen, H.E.2    Ritter, M.A.3
  • 22
    • 26244432100 scopus 로고    scopus 로고
    • Prevention of wound contamination using DuraPrep solution plus Ioban 2 drapes
    • Jacobson C., Osmon D.R., Hanssen A., et al. Prevention of wound contamination using DuraPrep solution plus Ioban 2 drapes. Clin Orthop Relat Res 439 (2005) 32
    • (2005) Clin Orthop Relat Res , vol.439 , pp. 32
    • Jacobson, C.1    Osmon, D.R.2    Hanssen, A.3
  • 23
    • 0022369904 scopus 로고
    • Development of a safe and effective one-minute preoperative skin preparation
    • Alexander J.W., Aerni S., and Plettner J.P. Development of a safe and effective one-minute preoperative skin preparation. Arch Surg 120 (1985) 1357
    • (1985) Arch Surg , vol.120 , pp. 1357
    • Alexander, J.W.1    Aerni, S.2    Plettner, J.P.3
  • 24
    • 0018754645 scopus 로고
    • A microbiological in-use comparison of surgical hand-washing agents
    • Eitzen H.E., Ritter M.A., French M.L., et al. A microbiological in-use comparison of surgical hand-washing agents. J Bone Joint Surg Am 61 (1979) 403
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 403
    • Eitzen, H.E.1    Ritter, M.A.2    French, M.L.3
  • 25
    • 33744900652 scopus 로고    scopus 로고
    • Surgical hand scrubs in relation to microbial counts: systematic literature review
    • Hsieh H.F., Chiu H.H., and Lee F.P. Surgical hand scrubs in relation to microbial counts: systematic literature review. J Adv Nurs 55 (2006) 68
    • (2006) J Adv Nurs , vol.55 , pp. 68
    • Hsieh, H.F.1    Chiu, H.H.2    Lee, F.P.3
  • 26
    • 0030960426 scopus 로고    scopus 로고
    • An evaluation of five protocols for surgical handwashing in relation to skin condition and microbial counts
    • Pereira L.J., Lee G.M., and Wade K.J. An evaluation of five protocols for surgical handwashing in relation to skin condition and microbial counts. J Hosp Infect 36 (1997) 49
    • (1997) J Hosp Infect , vol.36 , pp. 49
    • Pereira, L.J.1    Lee, G.M.2    Wade, K.J.3
  • 27
    • 0028212551 scopus 로고
    • Evaluation of the optimal hand-scrub duration prior to total hip arthroplasty
    • O'Farrell D.A., Kenny G., O'Sullivan M., et al. Evaluation of the optimal hand-scrub duration prior to total hip arthroplasty. J Hosp Infect 26 (1994) 93
    • (1994) J Hosp Infect , vol.26 , pp. 93
    • O'Farrell, D.A.1    Kenny, G.2    O'Sullivan, M.3
  • 28
    • 0032886756 scopus 로고    scopus 로고
    • Intraoperative bacterial contamination in operations for joint replacement
    • Davis N., Curry A., Gambhir A.K., et al. Intraoperative bacterial contamination in operations for joint replacement. J Bone Joint Surg Br 81 (1999) 886
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 886
    • Davis, N.1    Curry, A.2    Gambhir, A.K.3
  • 29
    • 16844382824 scopus 로고    scopus 로고
    • Perioperative contamination in primary total hip arthroplasty
    • Maathuis P.G., Neut D., Busscher H.J., et al. Perioperative contamination in primary total hip arthroplasty. Clin Orthop Relat Res 433 (2005) 136
    • (2005) Clin Orthop Relat Res , vol.433 , pp. 136
    • Maathuis, P.G.1    Neut, D.2    Busscher, H.J.3
  • 30
    • 0027285677 scopus 로고
    • Infection and interposition between ultraclean air source and wound
    • Taylor G.J., and Bannister G.C. Infection and interposition between ultraclean air source and wound. J Bone Joint Surg Br 75 (1993) 503
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 503
    • Taylor, G.J.1    Bannister, G.C.2
  • 32
    • 0023820224 scopus 로고
    • Bacteriologic contamination of suction tips during hip arthroplasty
    • Strange-Vognsen H.H., and Klareskov B. Bacteriologic contamination of suction tips during hip arthroplasty. Acta Orthop Scand 59 (1988) 410
    • (1988) Acta Orthop Scand , vol.59 , pp. 410
    • Strange-Vognsen, H.H.1    Klareskov, B.2
  • 33
    • 0027327498 scopus 로고
    • Suction tip contamination in the ultraclean-air operating theatre
    • Robinson A.H., Drew S., Anderson J., et al. Suction tip contamination in the ultraclean-air operating theatre. Ann R Coll Surg Engl 75 (1993) 254
    • (1993) Ann R Coll Surg Engl , vol.75 , pp. 254
    • Robinson, A.H.1    Drew, S.2    Anderson, J.3
  • 34
    • 0016967327 scopus 로고
    • Evaluation of microbial contamination of surgical gloves during actual use
    • Ritter M.A., French M.L., and Eitzen H. Evaluation of microbial contamination of surgical gloves during actual use. Clin Orthop Relat Res 117 (1976) 303
    • (1976) Clin Orthop Relat Res , vol.117 , pp. 303
    • Ritter, M.A.1    French, M.L.2    Eitzen, H.3
  • 35
    • 0025041402 scopus 로고
    • Outer gloves in orthopaedic procedures. Cloth compared with latex
    • Sanders R., Fortin P., Ross E., et al. Outer gloves in orthopaedic procedures. Cloth compared with latex. J Bone Joint Surg Am 72 (1990) 914
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 914
    • Sanders, R.1    Fortin, P.2    Ross, E.3
  • 36
    • 0019495070 scopus 로고
    • Efficacy of double-gloving as a barrier to microbial contamination during total joint arthroplasty
    • McCue S.F., Berg E.W., and Saunders E.A. Efficacy of double-gloving as a barrier to microbial contamination during total joint arthroplasty. J Bone Joint Surg Am 63 (1981) 811
    • (1981) J Bone Joint Surg Am , vol.63 , pp. 811
    • McCue, S.F.1    Berg, E.W.2    Saunders, E.A.3
  • 38
    • 0025911980 scopus 로고
    • Surgical face masks in modern operating rooms-a costly and unnecessary ritual?
    • Mitchell N.J., and Hunt S. Surgical face masks in modern operating rooms-a costly and unnecessary ritual?. J Hosp Infect 18 (1991) 239
    • (1991) J Hosp Infect , vol.18 , pp. 239
    • Mitchell, N.J.1    Hunt, S.2
  • 39
    • 0025899947 scopus 로고
    • Postoperative wound infections and surgical face masks: a controlled study
    • Tunevall T.G. Postoperative wound infections and surgical face masks: a controlled study. World J Surg 15 (1991) 383
    • (1991) World J Surg , vol.15 , pp. 383
    • Tunevall, T.G.1
  • 40
    • 0020611951 scopus 로고
    • Conversation in the operating theater as a cause of airborne bacterial contamination
    • Letts R.M., and Doermer E. Conversation in the operating theater as a cause of airborne bacterial contamination. J Bone Joint Surg Am 65 (1983) 357
    • (1983) J Bone Joint Surg Am , vol.65 , pp. 357
    • Letts, R.M.1    Doermer, E.2
  • 41
    • 0037764921 scopus 로고    scopus 로고
    • Body-exhaust suit versus occlusive clothing. A randomised, prospective trial using air and wound bacterial counts
    • Der Tavitian J., Ong S.M., Taub N.A., et al. Body-exhaust suit versus occlusive clothing. A randomised, prospective trial using air and wound bacterial counts. J Bone Joint Surg Br 85 (2003) 490
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 490
    • Der Tavitian, J.1    Ong, S.M.2    Taub, N.A.3
  • 42
    • 0025521350 scopus 로고
    • Reduction of contamination at total hip replacement by special working clothes
    • Blomgren G., Hoborn J., and Nystrom B. Reduction of contamination at total hip replacement by special working clothes. J Bone Joint Surg Br 72 (1990) 985
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 985
    • Blomgren, G.1    Hoborn, J.2    Nystrom, B.3
  • 43
    • 0020565878 scopus 로고
    • A bacteriologically occlusive clothing system for use in the operating room
    • Whyte W., Bailey P.V., Hamblen D.L., et al. A bacteriologically occlusive clothing system for use in the operating room. J Bone Joint Surg Br 65 (1983) 502
    • (1983) J Bone Joint Surg Br , vol.65 , pp. 502
    • Whyte, W.1    Bailey, P.V.2    Hamblen, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.