메뉴 건너뛰기




Volumn 74, Issue 2, 2007, Pages 122-126

Fiber optic interferometric sensor for acoustic detection of partial discharges

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC SIGNAL PROCESSING; CALIBRATION; INTERFEROMETRY; MACH-ZEHNDER INTERFEROMETERS;

EID: 34848839616     PISSN: 10709762     EISSN: None     Source Type: Journal    
DOI: 10.1364/JOT.74.000122     Document Type: Article
Times cited : (39)

References (12)
  • 1
    • 84945715370 scopus 로고
    • Partial discharge - part XIV: Acoustic partial discharge detection - practical application
    • L. E. Lundgaard, "Partial discharge - part XIV: acoustic partial discharge detection - practical application," IEEE Electrical Insulation Magazine 8, 34-43 (1992).
    • (1992) IEEE Electrical Insulation Magazine , vol.8 , pp. 34-43
    • Lundgaard, L.E.1
  • 2
    • 0036683416 scopus 로고    scopus 로고
    • Development of a fiber-optic sensor for partial discharges in oil-filled power transformers
    • M. MacAlpine, Z. Zhiqiang, and M. S. Demokan, "Development of a fiber-optic sensor for partial discharges in oil-filled power transformers," Electric Power Syst. Res. 63, 27-36 (2002).
    • (2002) Electric Power Syst. Res , vol.63 , pp. 27-36
    • MacAlpine, M.1    Zhiqiang, Z.2    Demokan, M.S.3
  • 3
    • 0033706584 scopus 로고    scopus 로고
    • The Directionality of an optical fiber high-frequency acoustic sensor for partial discharge detection and location
    • Z. Zhiqiang, M. MacAlpine, and M. S. Demokan, "The Directionality of an optical fiber high-frequency acoustic sensor for partial discharge detection and location," J. Lightwave Technol. 18, No. 6, 795-806 (2000).
    • (2000) J. Lightwave Technol , vol.18 , Issue.6 , pp. 795-806
    • Zhiqiang, Z.1    MacAlpine, M.2    Demokan, M.S.3
  • 4
    • 0029720966 scopus 로고    scopus 로고
    • Modified optical fiber sensor for PD detection in high-voltage power equipment
    • Montreal
    • A. Zargari and T. R. Blackburn, "Modified optical fiber sensor for PD detection in high-voltage power equipment," IEEE International Symposium on Electrical Insulation, Montreal (1996), pp. 424-427.
    • (1996) IEEE International Symposium on Electrical Insulation , pp. 424-427
    • Zargari, A.1    Blackburn, T.R.2
  • 5
    • 0034461434 scopus 로고    scopus 로고
    • Optical partial discharge sensor for on-line monitoring of oil insulated transformers
    • C. Helmig, R. Merte, and K. Temmen, "Optical partial discharge sensor for on-line monitoring of oil insulated transformers," Proc. SPIE 4185, 1-9 (2000).
    • (2000) Proc. SPIE , vol.4185 , pp. 1-9
    • Helmig, C.1    Merte, R.2    Temmen, K.3
  • 6
    • 0035398323 scopus 로고    scopus 로고
    • Optical fiber sensor-based detection of partial discharges in power transformers
    • J. Deng, H. Xiao, W. Huo, M. Luo, R. May, A. Wang, and Y. Liu, "Optical fiber sensor-based detection of partial discharges in power transformers," Opt. Laser Technol. 33, 305-311 (2001).
    • (2001) Opt. Laser Technol , vol.33 , pp. 305-311
    • Deng, J.1    Xiao, H.2    Huo, W.3    Luo, M.4    May, R.5    Wang, A.6    Liu, Y.7
  • 7
    • 0034261995 scopus 로고    scopus 로고
    • Measurements of mechanical vibrations at magnetic cores of power transformers with fiber-optic interferometric intrinsic sensor
    • H. Lamela, J. A. García-Souto, and J. Sanz, "Measurements of mechanical vibrations at magnetic cores of power transformers with fiber-optic interferometric intrinsic sensor," IEEE J. Sel. Top. Quantum Electron. 6, 788-797 (2000).
    • (2000) IEEE J. Sel. Top. Quantum Electron , vol.6 , pp. 788-797
    • Lamela, H.1    García-Souto, J.A.2    Sanz, J.3
  • 8
    • 0037237158 scopus 로고    scopus 로고
    • Detection and wavelet analysis of partial discharges using an optical fibre interferometric sensor for high-power transformers
    • H. Lamela-Rivera, C. Macià-Sanahuja, J. A. Garciía-Souto, "Detection and wavelet analysis of partial discharges using an optical fibre interferometric sensor for high-power transformers," J. Opt. A. 5, 66-72 (2003).
    • (2003) J. Opt. A , vol.5 , pp. 66-72
    • Lamela-Rivera, H.1    Macià-Sanahuja, C.2    Garciía-Souto, J.A.3
  • 9
    • 84894010378 scopus 로고    scopus 로고
    • C. Macià-Sanahuja, J. A. García-Souto, and H. Lamela, Characterization of an ultrasonic low frequency fibre optic interferometric sensor for partial discharges detection in transformers, Proceedings of OSAV'2004, International Topical Meeting on Optical Sensing and Artificial Vision, State University ITMO, Saint Petersburg, Russia (2004), pp. 157-163.
    • C. Macià-Sanahuja, J. A. García-Souto, and H. Lamela, "Characterization of an ultrasonic low frequency fibre optic interferometric sensor for partial discharges detection in transformers," Proceedings of OSAV'2004, International Topical Meeting on Optical Sensing and Artificial Vision, State University ITMO, Saint Petersburg, Russia (2004), pp. 157-163.
  • 10
    • 84893985858 scopus 로고    scopus 로고
    • R. T. Harrold, Engineering Dielectrics. 1: Corona Measurement and Interpretation, Chap. 10, Acoustical techniques for detecting and locating electrical discharges, ASTM Publication No. 669, 358-408 (1979).
    • R. T. Harrold, Engineering Dielectrics. Vol. 1: Corona Measurement and Interpretation, Chap. 10, "Acoustical techniques for detecting and locating electrical discharges," ASTM Publication No. 669, 358-408 (1979).
  • 11
    • 0028496014 scopus 로고
    • An ultrasonic fiber-optic hydrophone incorporating a push-pull transducer in a Sagnac interferometer
    • S. Knudsen and K. Blotekjaer, "An ultrasonic fiber-optic hydrophone incorporating a push-pull transducer in a Sagnac interferometer," J. Lightwave Technol. 12, No. 9, 1696-1700 (1994).
    • (1994) J. Lightwave Technol , vol.12 , Issue.9 , pp. 1696-1700
    • Knudsen, S.1    Blotekjaer, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.