메뉴 건너뛰기




Volumn 122, Issue 4, 2007, Pages 2469-2475

Attenuation in trabecular bone: A comparison between numerical simulation and experimental results in human femur

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; FINITE DIFFERENCE TIME DOMAIN METHOD; GEOMETRY; ULTRASONIC PROPAGATION; ULTRASONICS; VOLUME FRACTION;

EID: 34848832309     PISSN: 00014966     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.2766779     Document Type: Article
Times cited : (60)

References (26)
  • 1
    • 33751507147 scopus 로고    scopus 로고
    • A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur
    • Barkmann, R., Laugier, P., Moser, U., Dencks, S., Padilla, F., Haiat, G., Heller, M., and Gluer, C. C. (2007). " A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur., " Bone (N.Y.) 40, 37-44.
    • (2007) Bone (N.Y.) , vol.40 , pp. 37-44
    • Barkmann, R.1    Laugier, P.2    Moser, U.3    Dencks, S.4    Padilla, F.5    Haiat, G.6    Heller, M.7    Gluer, C.C.8
  • 2
    • 28644451513 scopus 로고    scopus 로고
    • Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography
    • Bossy, E., Padilla, F., Peyrin, F., and Laugier, P. (2005). " Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography., " Phys. Med. Biol. 50, 5545-5556.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 5545-5556
    • Bossy, E.1    Padilla, F.2    Peyrin, F.3    Laugier, P.4
  • 3
    • 2142716028 scopus 로고    scopus 로고
    • Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models
    • Bossy, E., Talmant, M., and Laugier, P. (2004). " Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models., " J. Acoust. Soc. Am. 115, 2314-2324.
    • (2004) J. Acoust. Soc. Am. , vol.115 , pp. 2314-2324
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 4
    • 0033813008 scopus 로고    scopus 로고
    • In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz
    • Chaffai, S., Padilla, F., Berger, G., and Laugier, P. (2000). " In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz., " J. Acoust. Soc. Am. 108, 1281-1289.
    • (2000) J. Acoust. Soc. Am. , vol.108 , pp. 1281-1289
    • Chaffai, S.1    Padilla, F.2    Berger, G.3    Laugier, P.4
  • 5
    • 0036140389 scopus 로고    scopus 로고
    • Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: Relationships to density and microstructure
    • Chaffai, S., Peyrin, F., Nuzzo, S., Porcher, R., Berger, G., and Laugier, P. (2002). " Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: Relationships to density and microstructure., " Bone (N.Y.) 30, 229-237.
    • (2002) Bone (N.Y.) , vol.30 , pp. 229-237
    • Chaffai, S.1    Peyrin, F.2    Nuzzo, S.3    Porcher, R.4    Berger, G.5    Laugier, P.6
  • 6
    • 0035071437 scopus 로고    scopus 로고
    • Application of the PML absorbing layer model to the linear elastodynamic problem in anisotropic heterogeneous media
    • Collino, F., and Tsogka, C. (2001). " Application of the PML absorbing layer model to the linear elastodynamic problem in anisotropic heterogeneous media., " Geophysics 66, 294-307.
    • (2001) Geophysics , vol.66 , pp. 294-307
    • Collino, F.1    Tsogka, C.2
  • 7
    • 3142678029 scopus 로고    scopus 로고
    • Ultrasonic wave propagation in human cancellous bone: Application of Biot theory
    • Fellah, Z. E. A., Chapelon, J. Y., Berger, S., Lauriks, W., and Depollier, C. (2004). " Ultrasonic wave propagation in human cancellous bone: Application of Biot theory., " J. Acoust. Soc. Am. 116, 61-73.
    • (2004) J. Acoust. Soc. Am. , vol.116 , pp. 61-73
    • Fellah, Z.E.A.1    Chapelon, J.Y.2    Berger, S.3    Lauriks, W.4    Depollier, C.5
  • 9
    • 34447529339 scopus 로고    scopus 로고
    • Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: A 3D model simulation
    • Haiat, G., Padilla, F., Peyrin, F., and Laugier, P. (2007). " Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: A 3D model simulation., " J. Bone Miner. Res. 22, 665-674.
    • (2007) J. Bone Miner. Res. , vol.22 , pp. 665-674
    • Haiat, G.1    Padilla, F.2    Peyrin, F.3    Laugier, P.4
  • 10
    • 24944526636 scopus 로고    scopus 로고
    • Simulation of ultrasound propagation through bovine cancellous bone using elastic and Biot's finite-difference time-domain methods
    • Hosokawa, A. (2005). " Simulation of ultrasound propagation through bovine cancellous bone using elastic and Biot's finite-difference time-domain methods., " J. Acoust. Soc. Am. 118, 1782-1789.
    • (2005) J. Acoust. Soc. Am. , vol.118 , pp. 1782-1789
    • Hosokawa, A.1
  • 12
    • 0032971721 scopus 로고    scopus 로고
    • Ultrasonic propagation in cancellous bone: A new stratified model
    • Hughes, E. R., Leighton, T. G., Petley, G. W., and White, P. R. (1999). " Ultrasonic propagation in cancellous bone: A new stratified model., " Ultrasound Med. Biol. 25, 811-821.
    • (1999) Ultrasound Med. Biol. , vol.25 , pp. 811-821
    • Hughes, E.R.1    Leighton, T.G.2    Petley, G.W.3    White, P.R.4
  • 13
    • 30844447444 scopus 로고    scopus 로고
    • In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements: Relationships to bone mineral density
    • Jenson, F., Padilla, F., Bousson, V., Bergot, C., Laredo, J. D., and Laugier, P. (2006). " In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements: Relationships to bone mineral density., " J. Acoust. Soc. Am. 119, 654-663.
    • (2006) J. Acoust. Soc. Am. , vol.119 , pp. 654-663
    • Jenson, F.1    Padilla, F.2    Bousson, V.3    Bergot, C.4    Laredo, J.D.5    Laugier, P.6
  • 14
    • 1642452734 scopus 로고    scopus 로고
    • Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study
    • Khaw, K. T., Reeve, J., Luben, R., Bingham, S., Welch, A., Wareham, N., Oakes, S., and Day, N. (2004). " Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study., " Lancet 363, 197-202.
    • (2004) Lancet , vol.363 , pp. 197-202
    • Khaw, K.T.1    Reeve, J.2    Luben, R.3    Bingham, S.4    Welch, A.5    Wareham, N.6    Oakes, S.7    Day, N.8
  • 15
    • 0022702807 scopus 로고
    • Ultrasonic wave propagation and attenuation in wet bone
    • Lakes, R., Yoon, H. S., and Katz, J. L. (1986). " Ultrasonic wave propagation and attenuation in wet bone., " J. Biomed. Eng. 8, 143-148.
    • (1986) J. Biomed. Eng. , vol.8 , pp. 143-148
    • Lakes, R.1    Yoon, H.S.2    Katz, J.L.3
  • 16
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography
    • Laugier, P., Droin, P., LavalJeantet, A. M., and Berger, G. (1997). " In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography., " Bone (N.Y.) 20, 157-165.
    • (1997) Bone (N.Y.) , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Lavaljeantet, A.M.3    Berger, G.4
  • 17
    • 0142058352 scopus 로고    scopus 로고
    • Acoustic wave propagation in bovine cancellous bone: Application of the modified Biot-Attenborough model
    • Lee, K. I., Roh, H. S., and Yoon, S. W. (2003). " Acoustic wave propagation in bovine cancellous bone: Application of the modified Biot-Attenborough model., " J. Acoust. Soc. Am. 114, 2284-2293.
    • (2003) J. Acoust. Soc. Am. , vol.114 , pp. 2284-2293
    • Lee, K.I.1    Roh, H.S.2    Yoon, S.W.3
  • 21
    • 0037324604 scopus 로고    scopus 로고
    • Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure
    • Padilla, F., Peyrin, F., and Laugier, P. (2003). " Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure., " J. Acoust. Soc. Am. 113, 1122-1129.
    • (2003) J. Acoust. Soc. Am. , vol.113 , pp. 1122-1129
    • Padilla, F.1    Peyrin, F.2    Laugier, P.3
  • 22
    • 0032706138 scopus 로고    scopus 로고
    • A synchrotron radiation microtomography system for the analysis of trabecular bone samples
    • Salome, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A. M., Baruchel, J., and Spanne, P. (1999). " A synchrotron radiation microtomography system for the analysis of trabecular bone samples., " Med. Phys. 26, 2194-2204.
    • (1999) Med. Phys. , vol.26 , pp. 2194-2204
    • Salome, M.1    Peyrin, F.2    Cloetens, P.3    Odet, C.4    Laval-Jeantet, A.M.5    Baruchel, J.6    Spanne, P.7
  • 23
    • 0027897655 scopus 로고
    • Stress-relaxation function of bone and bone-collagen
    • Sasaki, N., Nakayama, Y., Yoshikawa, M., and Enyo, A. (1993). " Stress-relaxation function of bone and bone-collagen., " J. Biomech. 26, 1369-1376.
    • (1993) J. Biomech. , vol.26 , pp. 1369-1376
    • Sasaki, N.1    Nakayama, Y.2    Yoshikawa, M.3    Enyo, A.4
  • 24
    • 33644522708 scopus 로고    scopus 로고
    • Long-term fracture prediction by DXA and QUS: A 10-year prospective study
    • Stewart, A., Kumar, V., and Reid, D. M. (2006). " Long-term fracture prediction by DXA and QUS: A 10-year prospective study., " J. Bone Miner. Res. 21, 413-418.
    • (2006) J. Bone Miner. Res. , vol.21 , pp. 413-418
    • Stewart, A.1    Kumar, V.2    Reid, D.M.3
  • 25
    • 0032761734 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment
    • Wear, K. A. (1999). " Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment., " J. Acoust. Soc. Am. 106, 3659-3664.
    • (1999) J. Acoust. Soc. Am. , vol.106 , pp. 3659-3664
    • Wear, K.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.