메뉴 건너뛰기




Volumn 93, Issue 2, 2008, Pages 316-324

A method for identifying instrument faults in nuclear power plants possibly leading to wrong situation assessment

Author keywords

Human reliability analysis; Instrument faults; Nuclear power plant operator; Probabilistic safety assessment

Indexed keywords

FAILURE ANALYSIS; NUCLEAR REACTOR SIMULATORS; SAFETY ENGINEERING;

EID: 34848824992     PISSN: 09518320     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ress.2006.10.023     Document Type: Article
Times cited : (9)

References (7)
  • 1
    • 34848827811 scopus 로고    scopus 로고
    • Barriere M, Bley D, Cooper S, Forester J, Kolaczkowski A, Luckas W, Parry G, Ramey-smith A, Thompson C, Whitehead D, Wreathall J. Technical Basis and Implementation Guideline for A Technique for Human Event Analysis (ATHEANA). NUREG-1624, Rev. 1, 2000, US Nuclear Regulatory Commission: Washington, DC.
  • 2
    • 14844361782 scopus 로고    scopus 로고
    • A systematic approach to analysing errors of commission from diagnosis failure in accident progression
    • Kim J.W., Jung W., and Park J. A systematic approach to analysing errors of commission from diagnosis failure in accident progression. Reliab Eng Syst Safety 89 (2005) 137-150
    • (2005) Reliab Eng Syst Safety , vol.89 , pp. 137-150
    • Kim, J.W.1    Jung, W.2    Park, J.3
  • 3
    • 0004223940 scopus 로고
    • Cambridge University Press, New York
    • Reason J. Human Error (1990), Cambridge University Press, New York
    • (1990) Human Error
    • Reason, J.1
  • 4
    • 0542399658 scopus 로고
    • Operator assistant systems
    • Hollnagel E., Mancini G., and Woods D.D. (Eds), Academic Press, London
    • Boy G.A. Operator assistant systems. In: Hollnagel E., Mancini G., and Woods D.D. (Eds). Cognitive engineering in complex dynamic worlds (1988), Academic Press, London
    • (1988) Cognitive engineering in complex dynamic worlds
    • Boy, G.A.1
  • 5
    • 29144527079 scopus 로고    scopus 로고
    • An analytic model for situation assessment of nuclear power plant operators based on Bayesian inference
    • Kim M.C., and Seong P.H. An analytic model for situation assessment of nuclear power plant operators based on Bayesian inference. Reliab Eng Syst Safety 91 (2006) 270-282
    • (2006) Reliab Eng Syst Safety , vol.91 , pp. 270-282
    • Kim, M.C.1    Seong, P.H.2
  • 6
    • 0033279099 scopus 로고    scopus 로고
    • The real-time functional test facility for advanced instrumentation and control in nuclear power plants
    • Kwon K.-C., Song S.-J., Park W.-M., and Lyu S.-P. The real-time functional test facility for advanced instrumentation and control in nuclear power plants. IEEE Trans Nucl Sci 46 (1999) 92-99
    • (1999) IEEE Trans Nucl Sci , vol.46 , pp. 92-99
    • Kwon, K.-C.1    Song, S.-J.2    Park, W.-M.3    Lyu, S.-P.4
  • 7
    • 34848913971 scopus 로고    scopus 로고
    • LEE JK, Private communications, 2005.