메뉴 건너뛰기




Volumn 41, Issue 11, 2007, Pages 975-980

Simultaneous measurements of PM10 and PM1 using a single TEOM

Author keywords

[No Author keywords available]

Indexed keywords

FUNCTION EVALUATION; MEASUREMENT THEORY; SYSTEMATIC ERRORS;

EID: 34848821918     PISSN: 02786826     EISSN: 15217388     Source Type: Journal    
DOI: 10.1080/02786820701639715     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0035078855 scopus 로고    scopus 로고
    • Comment on Regression Analysis of Air Quality Data
    • Ayers, G. P. (2001). Comment on Regression Analysis of Air Quality Data, Atmos. Env. 35:2423-2425.
    • (2001) Atmos. Env , vol.35 , pp. 2423-2425
    • Ayers, G.P.1
  • 2
    • 2442573609 scopus 로고    scopus 로고
    • Potential for Simultaneous Measurement of PM10, PM2.5 and PM1 for Air Quality Monitoring Purposes Using a Single TEOM
    • Ayers, G. P. (2004). Potential for Simultaneous Measurement of PM10, PM2.5 and PM1 for Air Quality Monitoring Purposes Using a Single TEOM, Atmos. Env. 38:3453-3458.
    • (2004) Atmos. Env , vol.38 , pp. 3453-3458
    • Ayers, G.P.1
  • 4
    • 0345377003 scopus 로고    scopus 로고
    • Quantitative Interpretation of Divergence Between PM10 and PM2.5 Mass Measurement by TEOM and Gravimetric (Partisol) Instruments
    • Charron, A., Harrison, R. M., Moorcroft, S., and Booker, J. (2004). Quantitative Interpretation of Divergence Between PM10 and PM2.5 Mass Measurement by TEOM and Gravimetric (Partisol) Instruments, Atmos. Env. 38:415-423.
    • (2004) Atmos. Env , vol.38 , pp. 415-423
    • Charron, A.1    Harrison, R.M.2    Moorcroft, S.3    Booker, J.4
  • 6
    • 0035922590 scopus 로고    scopus 로고
    • PM2.5 Measurements in Ambient Aerosol: Comparison Between Harvard Impactor (HI) and the Tapered Element Oscillating Microbalance (TEOM) System
    • Cyrys, J., Dietrich, G., Kreyling, W., Tuch, T., and Heinrich, J. (2001). PM2.5 Measurements in Ambient Aerosol: Comparison Between Harvard Impactor (HI) and the Tapered Element Oscillating Microbalance (TEOM) System, Science Total Environ. 278:191-197.
    • (2001) Science Total Environ , vol.278 , pp. 191-197
    • Cyrys, J.1    Dietrich, G.2    Kreyling, W.3    Tuch, T.4    Heinrich, J.5
  • 8
    • 17344373833 scopus 로고    scopus 로고
    • A New Method to Link PM10 Concentrations from Automatic Monitors to the Manual Gravimetric Reference Method According to EN12341
    • Gehrig, R., Hueglin, C., Schwarzenbach, B., Seitz, T., and Buchmann, B. (2005). A New Method to Link PM10 Concentrations from Automatic Monitors to the Manual Gravimetric Reference Method According to EN12341, Atmos. Env. 39:2213-2223.
    • (2005) Atmos. Env , vol.39 , pp. 2213-2223
    • Gehrig, R.1    Hueglin, C.2    Schwarzenbach, B.3    Seitz, T.4    Buchmann, B.5
  • 10
    • 33745920197 scopus 로고    scopus 로고
    • Dominant Mechanisms that Shape the Airborne Particle Size and Composition Distribution in Central California
    • Herner, J. D., Ying, Q., Aw, J., Gao, O., Chang, D. P. Y., and Kleeman, M. J. (2006). Dominant Mechanisms that Shape the Airborne Particle Size and Composition Distribution in Central California, Aerosol Sci. Technol. 40:827-844.
    • (2006) Aerosol Sci. Technol , vol.40 , pp. 827-844
    • Herner, J.D.1    Ying, Q.2    Aw, J.3    Gao, O.4    Chang, D.P.Y.5    Kleeman, M.J.6
  • 12
    • 34848928340 scopus 로고
    • US Patent 3,926,271
    • Patashnik, H. (1975). US Patent 3,926,271.
    • (1975)
    • Patashnik, H.1
  • 13
    • 34848842046 scopus 로고    scopus 로고
    • Patashnick, H., and Rupprecht, E. G. (1979). A New Real Time Aerosol Mass Monitoring Instrument: The TEOM in Proceedings: Advances in Particulate Sampling and Measurement (Daytona Beach, FL), Smith, W., ed., U.S. Environmental Protection Agency, Washington, D.C., EPA/600/9-80/004.
    • Patashnick, H., and Rupprecht, E. G. (1979). A New Real Time Aerosol Mass Monitoring Instrument: The TEOM in Proceedings: Advances in Particulate Sampling and Measurement (Daytona Beach, FL), Smith, W., ed., U.S. Environmental Protection Agency, Washington, D.C., EPA/600/9-80/004.
  • 14
    • 0025848155 scopus 로고
    • Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance
    • Patashnick, H., and Rupprecht, E. G. (1991). Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance, J . Air Waste Manage. Assoc. 41:1079-1083.
    • (1991) J . Air Waste Manage. Assoc , vol.41 , pp. 1079-1083
    • Patashnick, H.1    Rupprecht, E.G.2
  • 15
    • 0035175309 scopus 로고    scopus 로고
    • Development of a Reference Standard for Particulate Matter Mass in Ambient Air
    • Patashnick, H., Rupprecht, E. G., Ambs, J. L., and Meyer, M. B. (2001). Development of a Reference Standard for Particulate Matter Mass in Ambient Air, Aerosol Sci. Technol. 34:42-45.
    • (2001) Aerosol Sci. Technol , vol.34 , pp. 42-45
    • Patashnick, H.1    Rupprecht, E.G.2    Ambs, J.L.3    Meyer, M.B.4
  • 16
    • 5044236860 scopus 로고    scopus 로고
    • Long-Term Field Characterization of Tapered Element Oscillating Microbalance and Modified Tapered Element Oscillating Microbalance Samplers in Urban and Rural New York State Locations
    • Schwab, J. J., Spicer, J., Demerjian, K. L., Ambs, J. L., and Felton, H. D. (2004). Long-Term Field Characterization of Tapered Element Oscillating Microbalance and Modified Tapered Element Oscillating Microbalance Samplers in Urban and Rural New York State Locations, J. Air Waste Manage. Assoc. 54:1264-1280.
    • (2004) J. Air Waste Manage. Assoc , vol.54 , pp. 1264-1280
    • Schwab, J.J.1    Spicer, J.2    Demerjian, K.L.3    Ambs, J.L.4    Felton, H.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.