메뉴 건너뛰기




Volumn 10, Issue 4, 2007, Pages 245-255

Modeling of stents exhibiting negative Poisson's ratio effect

Author keywords

Dogboning; Finite element method (FEM); Intravascular stents; Lumen

Indexed keywords

AXIAL CONTRACTIONS; BLOOD FLOW; DOGBONING; DOWN STREAM; EXPERIMENTAL EVALUATION; FINITE ELEMENT METHOD FEM; HYPER ELASTIC; INTRAVASCULAR STENTS; LUMEN; NEGATIVE POISSON'S RATIOS; RADIAL EXPANSIONS; STENOTIC ARTERIES; STENT GEOMETRY; STENTING; UNDESIRABLE EFFECTS;

EID: 34848817641     PISSN: 10255842     EISSN: 14768259     Source Type: Journal    
DOI: 10.1080/10255840701198004     Document Type: Article
Times cited : (22)

References (14)
  • 1
    • 18044381348 scopus 로고    scopus 로고
    • Finite-element analysis of stenotic artery revascularization through a stent insertion
    • F. Auricchio, M. Li Loreto and E. Sacco, "Finite-element analysis of stenotic artery revascularization through a stent insertion", Comput. Methods Biomech. Biomed. Eng., 00, pp. 1-15, 2000.
    • (2000) Comput. Methods Biomech. Biomed. Eng , vol.0 , pp. 1-15
    • Auricchio, F.1    Li Loreto, M.2    Sacco, E.3
  • 3
    • 10044294743 scopus 로고    scopus 로고
    • Effect of varying slotted tube (stent) geometry on its expansion behavior using finite element method
    • S.N. David Chua, B.J. Mac Donald and M.S.J. Hashmi, "Effect of varying slotted tube (stent) geometry on its expansion behavior using finite element method", J. Mat. Process. Technol., 155/156, pp. 1764-1771, 2004a.
    • (2004) J. Mat. Process. Technol , vol.155-156 , pp. 1764-1771
    • David Chua, S.N.1    Mac Donald, B.J.2    Hashmi, M.S.J.3
  • 4
    • 10044238835 scopus 로고    scopus 로고
    • Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion
    • S.N. David Chua, B.J. Mac Donald and M.S.J. Hashmi, "Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion", J. Mat. Process. Technol., 155/156, pp. 1772-1779, 2004b.
    • (2004) J. Mat. Process. Technol , vol.155-156 , pp. 1772-1779
    • David Chua, S.N.1    Mac Donald, B.J.2    Hashmi, M.S.J.3
  • 5
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behavior modeling of balloonexpandable stents
    • C. Domulin and B. Cochelin, "Mechanical behavior modeling of balloonexpandable stents", J. Biomech., 33, pp. 1461-1470, 2000.
    • (2000) J. Biomech , vol.33 , pp. 1461-1470
    • Domulin, C.1    Cochelin, B.2
  • 6
    • 0034930155 scopus 로고    scopus 로고
    • Mechanical properties of coronary stents determined by using finite element analysis
    • F. Etave, G. Finet, M. Boivin, J.-C. Boyer, G. Rioufol and G. Thollet, "Mechanical properties of coronary stents determined by using finite element analysis", J. Biomech., 34, pp. 1065-1075, 2001.
    • (2001) J. Biomech , vol.34 , pp. 1065-1075
    • Etave, F.1    Finet, G.2    Boivin, M.3    Boyer, J.-C.4    Rioufol, G.5    Thollet, G.6
  • 8
    • 18044372225 scopus 로고    scopus 로고
    • Finite element analysis of covered microstents
    • L. Gu, S. Santra, R.A. Mericle and A.V. Kumar, "Finite element analysis of covered microstents", J. Biomech., 38, pp. 1221-1227, 2005.
    • (2005) J. Biomech , vol.38 , pp. 1221-1227
    • Gu, L.1    Santra, S.2    Mericle, R.A.3    Kumar, A.V.4
  • 9
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stress: A finite element analysis
    • C. Lally, F. Dolan and P.J. Prendergast, "Cardiovascular stent design and vessel stress: a finite element analysis", J. Biomech., 38, pp. 1574-1581, 2005.
    • (2005) J. Biomech , vol.38 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 10
    • 25444471259 scopus 로고    scopus 로고
    • Finite element analysis of the implantation of a balloon expandable stent in a stenosed artery
    • D.K. Liang, D.Z. Yang and W.Q. Wang, "Finite element analysis of the implantation of a balloon expandable stent in a stenosed artery", Int. J. Cardiol., 104, pp. 314-318, 2005.
    • (2005) Int. J. Cardiol , vol.104 , pp. 314-318
    • Liang, D.K.1    Yang, D.Z.2    Wang, W.Q.3
  • 11
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • F. Magliavacca, L. Petrini, M. Colombo, F. Auricchio and R. Pietrabissa, "Mechanical behavior of coronary stents investigated through the finite element method", J. Biomech., 35, pp. 808-811, 2002.
    • (2002) J. Biomech , vol.35 , pp. 808-811
    • Magliavacca, F.1    Petrini, L.2    Colombo, M.3    Auricchio, F.4    Pietrabissa, R.5
  • 12
    • 1442299848 scopus 로고    scopus 로고
    • Numerical investigation of intravascular coronary stent flexibility
    • L. Petrini, F. Migliavacca, F. Auricchio and G. Dubini, "Numerical investigation of intravascular coronary stent flexibility", J. Biomech., 37, pp. 495-501, 2004.
    • (2004) J. Biomech , vol.37 , pp. 495-501
    • Petrini, L.1    Migliavacca, F.2    Auricchio, F.3    Dubini, G.4
  • 14
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • W.-Q. Wang, D.-K. Liang, D-Z. Yang and M. Qi, "Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method", J. Biomech., 39, pp. 21-32, 2006.
    • (2006) J. Biomech , vol.39 , pp. 21-32
    • Wang, W.-Q.1    Liang, D.-K.2    Yang, D.-Z.3    Qi, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.