메뉴 건너뛰기




Volumn 34, Issue 10, 2007, Pages 3732-3738

Resolution and noise trade-off analysis for volumetric CT

Author keywords

3D MTF; Noise; Spatial Resolution; Volumetric CT

Indexed keywords

ECONOMIC AND SOCIAL EFFECTS; IMAGE RESOLUTION; QUANTUM NOISE;

EID: 34748898317     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2779128     Document Type: Article
Times cited : (20)

References (11)
  • 1
    • 0017194985 scopus 로고
    • Statistical limitations in x-ray reconstruction tomography
    • R. Brooks and G. DiChiro, " Statistical limitations in x-ray reconstruction tomography., " Med. Phys. 3, 237-240 (1976).
    • (1976) Med. Phys. , vol.3 , pp. 237-240
    • Brooks, R.1    Dichiro, G.2
  • 2
    • 0017328286 scopus 로고
    • Noise due to photon counting statistics in computed x-ray tomography
    • D. Chesler, S. Riederer, and N. Pelc, " Noise due to photon counting statistics in computed x-ray tomography., " J. Comput. Assist. Tomogr. 1, 64-74 (1977).
    • (1977) J. Comput. Assist. Tomogr. , vol.1 , pp. 64-74
    • Chesler, D.1    Riederer, S.2    Pelc, N.3
  • 3
    • 0018197135 scopus 로고
    • Statistical limitations in computed tomography
    • J. Gore and P. Tofts, " Statistical limitations in computed tomography., " Phys. Med. Biol. 23, 1176-1182 (1978).
    • (1978) Phys. Med. Biol. , vol.23 , pp. 1176-1182
    • Gore, J.1    Tofts, P.2
  • 5
    • 4344683331 scopus 로고    scopus 로고
    • Tomographic imaging
    • edited by J.Beutel, H.Kundel, and R.Van Metter (SPIE, Bellingham, Washington
    • D. Goodenough, " Tomographic imaging., " in SPIE handbook of Medical Imaging (Vol. 1), edited by, J. Beutel,,, H. Kundel,, and, R. Van Metter, (SPIE, Bellingham, Washington, 2000), pp. 511-554.
    • (2000) SPIE Handbook of Medical Imaging , vol.1 , pp. 511-554
    • Goodenough, D.1
  • 7
    • 0035080793 scopus 로고    scopus 로고
    • Determination of the presampled MTF in computed tomography
    • J. Boone, " Determination of the presampled MTF in computed tomography., " Med. Phys. 28, 356-360 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 356-360
    • Boone, J.1
  • 8
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • E. Samei, M. Flynn, and D. Reimann, " A method for measuring the presampled MTF of digital radiographic systems using an edge test device., " Med. Phys. 25, 102-113 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.2    Reimann, D.3
  • 9
    • 33745368904 scopus 로고    scopus 로고
    • Measurement of spatial resolution of a clinical volumetric computed tomography scanner using a sphere phantom
    • SPIE
    • M. Thornton and M. Flynn, " Measurement of spatial resolution of a clinical volumetric computed tomography scanner using a sphere phantom., " in Proceedings of SPIE Medical Imaging Conference (SPIE, 2006), Vol. 6142, pp. 1Z1-10.
    • (2006) Proceedings of SPIE Medical Imaging Conference , vol.6142
    • Thornton, M.1    Flynn, M.2
  • 10
    • 0043194212 scopus 로고    scopus 로고
    • On the correlation of pixel noise, spatial resolution and dose in computed tomography
    • T. Fuchs and W. Kalender, " On the correlation of pixel noise, spatial resolution and dose in computed tomography., " Phys. Medica XIX, 153-164 (2003).
    • (2003) Phys. Medica , vol.19 , pp. 153-164
    • Fuchs, T.1    Kalender, W.2
  • 11
    • 0343340400 scopus 로고    scopus 로고
    • 3D cone-beam CT reconstruction for circular trajectories
    • M. M. Grass, " 3D cone-beam CT reconstruction for circular trajectories., " Phys. Med. Biol. 45, 329-347 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 329-347
    • Grass, M.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.