Development and implementation of a high-performance, cardiac-gated dual-energy imaging system

Author keywords

Cardiac gating; Dual energy imaging; Flat panel detector; Image acquisition technique; Image quality; Imaging dose; Imaging performance; Lung cancer; Optimization; Thoracic imaging

Indexed keywords

BIOPSY; COMPUTER CONTROL; FLAT PANEL DISPLAYS; IMAGE QUALITY; PROJECTION SYSTEMS; RADIOGRAPHY;

EID: 34748869212     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.713680     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 4
    • 0019450609 scopus 로고
    • A method for selective tissue and bone visualization using dual energy scanned projection radiography
    • W. R. Brody, G. Butt, A. Hall, and A. Macovski. "A method for selective tissue and bone visualization using dual energy scanned projection radiography," Medical Physics 8[3]: 353-357 (1981).
    • (1981) Medical Physics , vol.8 , Issue.3 , pp. 353-357
    • Brody, W.R.1    Butt, G.2    Hall, A.3    Macovski, A.4
  • 6
    • 0028082160 scopus 로고
    • Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules
    • F. Kelcz, F. E. Zink, W. W. Peppler, D. G. Kruger, D. L. Ergun, and C. A. Mistretta. "Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules," AJR Am.J.Roentgenol. 162[2]: 271-278 (1994).
    • (1994) AJR Am.J.Roentgenol , vol.162 , Issue.2 , pp. 271-278
    • Kelcz, F.1    Zink, F.E.2    Peppler, W.W.3    Kruger, D.G.4    Ergun, D.L.5    Mistretta, C.A.6
  • 9
    • 0034860950 scopus 로고    scopus 로고
    • The Development and Characterization of a Dual-Energy Subtraction Imaging System for Chest Radiography Based on Csl
    • SPIE: Physics of Medical Imaging
    • J. M. Sabol, G. B. Avinash, F. Nicolas, B. Claus, J. Zhao, and J. T. Dobbins. "The Development and Characterization of a Dual-Energy Subtraction Imaging System for Chest Radiography Based on Csl:T1 Amorphous Silicon Flat-Panel Technology," SPIE: Physics of Medical Imaging 4320: 399-408 (2001).
    • (2001) Amorphous Silicon Flat-Panel Technology , vol.T1
    • Sabol, J.M.1    Avinash, G.B.2    Nicolas, F.3    Claus, B.4    Zhao, J.5    Dobbins, J.T.6
  • 10
    • 18844408570 scopus 로고    scopus 로고
    • Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors
    • S. Richard, J. H. Siewerdsen, D. A. Jaffray, D. J. Moseley, and B. Bakhtiar. "Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors," Medical Physics 32[5]: 1397-1413 (2005).
    • (2005) Medical Physics , vol.32 , Issue.5 , pp. 1397-1413
    • Richard, S.1    Siewerdsen, J.H.2    Jaffray, D.A.3    Moseley, D.J.4    Bakhtiar, B.5
  • 11
    • 33845956459 scopus 로고    scopus 로고
    • Optimization of dual-energy imaging systems using generalized NEQ and imaging task
    • S. Richard and J. H. Siewerdsen. "Optimization of dual-energy imaging systems using generalized NEQ and imaging task," Medical Physics 34[1]: 127-139 (2007).
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 127-139
    • Richard, S.1    Siewerdsen, J.H.2
  • 12
    • 0037322222 scopus 로고    scopus 로고
    • Quantitative evaluation of noise reduction strategies in dual-energy imaging
    • R. J. Warp and J. T. Dobbins, III. "Quantitative evaluation of noise reduction strategies in dual-energy imaging," Medical Physics 30[2]: 190-198 (2003).
    • (2003) Medical Physics , vol.30 , Issue.2 , pp. 190-198
    • Warp, R.J.1    Dobbins III, J.T.2
  • 13
    • 9244249165 scopus 로고    scopus 로고
    • Spektr: A computational tool for x-ray spectral analysis and imaging system optimization
    • J. H. Siewerdsen, A. M. Waese, D. J. Moseley, S. Richard, and D. A. Jaffray. "Spektr: a computational tool for x-ray spectral analysis and imaging system optimization," Medical Physics 31[11]: 3057-3067 (2004).
    • (2004) Medical Physics , vol.31 , Issue.11 , pp. 3057-3067
    • Siewerdsen, J.H.1    Waese, A.M.2    Moseley, D.J.3    Richard, S.4    Jaffray, D.A.5
  • 14
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    • J. M. Boone and J. A. Seibert. "An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV," Medical Physics 24[11]: 1661-1670 (1997).
    • (1997) Medical Physics , vol.24 , Issue.11 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 15
    • 0026443715 scopus 로고
    • Parametrized x-ray absorption in diagnostic radiology from Monte Carlo calculations: Implications for x-ray detector design
    • J. M. Boone. "Parametrized x-ray absorption in diagnostic radiology from Monte Carlo calculations: implications for x-ray detector design," Medical Physics 19[6]: 1467-1473 (1992).
    • (1992) Medical Physics , vol.19 , Issue.6 , pp. 1467-1473
    • Boone, J.M.1
  • 16
    • 35148826073 scopus 로고    scopus 로고
    • AAPM Report No. 31, Standardized Methods for Measuring Diagnostic X-Ray Exposures, (1990). New York, American Institute of Physics. 17. Nationwide Evaluation of X-Ray Trends (NEXT): Tabulation and Graphical Summary of 2001 Survey of Adult Chest Radiography, (2005).
    • AAPM Report No. 31, Standardized Methods for Measuring Diagnostic X-Ray Exposures," (1990). New York, American Institute of Physics. 17. Nationwide Evaluation of X-Ray Trends (NEXT): Tabulation and Graphical Summary of 2001 Survey of Adult Chest Radiography," (2005).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.