메뉴 건너뛰기




Volumn 41, Issue 1, 2007, Pages 109-113

Short communication: Use of cefoxitin disc diffusion method for the detection of methicillin resistance in Staphylococcus aureus clinical isolates;Kisa bi̇ldi̇ri̇: Staphylococcus aureus kli̇ni̇k i̇zolatlarinda meti̇si̇li̇n di̇renci̇ni̇n tespi̇ti̇ i̇çi̇n sefoksi̇ti̇n di̇sk di̇füzyon yöntemi̇ni̇n kullanimi

Author keywords

Cefoxitin disc diffusion method; Methicillin resistant S.aureus; Staphylococcus aureus

Indexed keywords

ANTIINFECTIVE AGENT; CEFOXITIN; OXACILLIN;

EID: 34748867955     PISSN: 03749096     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (7)
  • 1
    • 15844408338 scopus 로고    scopus 로고
    • Evaluation of different methods for detecting methicillin (oxacillin) resistance in Staphylococcus aureus
    • Velasco D, Tomas MM, Cartelle M, et al. Evaluation of different methods for detecting methicillin (oxacillin) resistance in Staphylococcus aureus. J Antimicrob Chemother 2005; 55: 379-82.
    • (2005) J Antimicrob Chemother , vol.55 , pp. 379-382
    • Velasco, D.1    Tomas, M.M.2    Cartelle, M.3
  • 2
    • 20244388509 scopus 로고    scopus 로고
    • Cefoxitin resistance as a surrogate marker for the detection of methicillin-resistant Staphylococcus aureus
    • Fernandes CJ, Fernandes LA, Collignon P. Cefoxitin resistance as a surrogate marker for the detection of methicillin-resistant Staphylococcus aureus. J Antimicrob Chemother 2005, 55; 506-10.
    • (2005) J Antimicrob Chemother , vol.55 , pp. 506-510
    • Fernandes, C.J.1    Fernandes, L.A.2    Collignon, P.3
  • 3
    • 48149111272 scopus 로고    scopus 로고
    • th ed. Approved Standard M7-A5, NCCLS, Wayne, PA.
    • th ed. Approved Standard M7-A5, NCCLS, Wayne, PA.
  • 4
    • 48149095020 scopus 로고    scopus 로고
    • Performance standards for antimicrobial susceptibility testing
    • Clinical and Laboratory Standards Institute, CLSI, Wayne, PA
    • Clinical and Laboratory Standards Institute. Performance standards for antimicrobial susceptibility testing. 2004, 16th Informational Supplement M100-S14, CLSI, Wayne, PA.
    • (2004) 16th Informational , Issue.SUPPL.EMENT M100-S14
  • 5
    • 0036701939 scopus 로고    scopus 로고
    • Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA): A disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-Screen latex agglutination test
    • Felten A, Grandry B, Lagrange PH, Casin I. Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA): a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-Screen latex agglutination test. J Clin Microbiol 2002; 40: 2766-71.
    • (2002) J Clin Microbiol , vol.40 , pp. 2766-2771
    • Felten, A.1    Grandry, B.2    Lagrange, P.H.3    Casin, I.4
  • 6
    • 4544363946 scopus 로고    scopus 로고
    • Evaluation of a cefoxitin disk diffusion test for the routine detection of methicillin-resistant Staphylococcus aureus
    • Boubaker IBB, Abbes RB, Abdallah HB, et al. Evaluation of a cefoxitin disk diffusion test for the routine detection of methicillin-resistant Staphylococcus aureus. Clin Microbiol Infect 2004; 10: 762-5.
    • (2004) Clin Microbiol Infect , vol.10 , pp. 762-765
    • Boubaker, I.B.B.1    Abbes, R.B.2    Abdallah, H.B.3
  • 7
    • 11144281778 scopus 로고    scopus 로고
    • Cefoxitin disk diffusion screen for confirmation of oxacillin-resistant Staphylococcus aureus isolates and utility in the clinical laboratory
    • Sharp SE, Warren JA, Thomson RB Jr. Cefoxitin disk diffusion screen for confirmation of oxacillin-resistant Staphylococcus aureus isolates and utility in the clinical laboratory. Diagn Microbiol Infect Dis 2005; 51: 69-71.
    • (2005) Diagn Microbiol Infect Dis , vol.51 , pp. 69-71
    • Sharp, S.E.1    Warren, J.A.2    Thomson Jr., R.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.