메뉴 건너뛰기




Volumn 19, Issue 9, 2007, Pages 655-660

Comparison of 50 kV Facilities for Contact Radiotherapy

Author keywords

Contact radiotherapy; papillon technique; radiochromic film; rectal cancer

Indexed keywords

ARTICLE; COMPARATIVE STUDY; CONTACT RADIOTHERAPY; DOSIMETRY; EQUIPMENT DESIGN; HUMAN; ONCOLOGY; PRIORITY JOURNAL; RADIATION APPLICATOR; RADIATION DEPTH DOSE; RADIATION DOSE; RADIOTHERAPY;

EID: 34748853686     PISSN: 09366555     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clon.2007.07.005     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0025349480 scopus 로고
    • Present status of radiation therapy in the conservative management of rectal cancer
    • Papillon J. Present status of radiation therapy in the conservative management of rectal cancer. Radiother Oncol 17 (1990) 275-283
    • (1990) Radiother Oncol , vol.17 , pp. 275-283
    • Papillon, J.1
  • 3
    • 34748903737 scopus 로고    scopus 로고
    • The NCS code of practice for dosimetry of low- and medium-energy X-rays
    • Ma C.-M., and Seuntjens J.P. (Eds), Medical Physics Publishing, Wisconsin
    • Grimbergen T.W.M., Aalbers A.H.L., Mijnheer B.J., et al. The NCS code of practice for dosimetry of low- and medium-energy X-rays. In: Ma C.-M., and Seuntjens J.P. (Eds). Kilovoltage X-ray beam dosimetry for radiotherapy and radiobiology (1998), Medical Physics Publishing, Wisconsin 55-68
    • (1998) Kilovoltage X-ray beam dosimetry for radiotherapy and radiobiology , pp. 55-68
    • Grimbergen, T.W.M.1    Aalbers, A.H.L.2    Mijnheer, B.J.3
  • 4
    • 0032415881 scopus 로고    scopus 로고
    • Study of dosimetry consistency for kilovoltage X-ray beams
    • Ma C.-M., Li X.A., and Seuntjens J.P. Study of dosimetry consistency for kilovoltage X-ray beams. Med Phys 25 (1998) 2376-2384
    • (1998) Med Phys , vol.25 , pp. 2376-2384
    • Ma, C.-M.1    Li, X.A.2    Seuntjens, J.P.3
  • 5
    • 0031845774 scopus 로고    scopus 로고
    • Dosimetric evaluation of a widely used kilovoltage X-ray unit for endocavitary radiotherapy
    • Li X.A., Ma C.M., Salhani D., and Agboola O. Dosimetric evaluation of a widely used kilovoltage X-ray unit for endocavitary radiotherapy. Med Phys 25 (1998) 1464-1471
    • (1998) Med Phys , vol.25 , pp. 1464-1471
    • Li, X.A.1    Ma, C.M.2    Salhani, D.3    Agboola, O.4
  • 6
    • 0031442330 scopus 로고    scopus 로고
    • Measurement of percentage depth dose and lateral beam profile for kV X-ray therapy beams
    • Li X.A., Ma C.M., and Salhani D. Measurement of percentage depth dose and lateral beam profile for kV X-ray therapy beams. Phys Med Biol 42 (1997) 2561-2568
    • (1997) Phys Med Biol , vol.42 , pp. 2561-2568
    • Li, X.A.1    Ma, C.M.2    Salhani, D.3
  • 7
    • 0008796868 scopus 로고    scopus 로고
    • Radiochromic film dosimetry: recommendations of AAPM radiation therapy committee task group 55, American Association of Physics in Medicine
    • Niroomand-Rad A., Blackwell C.R., Coursey B.M., et al. Radiochromic film dosimetry: recommendations of AAPM radiation therapy committee task group 55, American Association of Physics in Medicine. Med Phys 25 (1998) 2093-2115
    • (1998) Med Phys , vol.25 , pp. 2093-2115
    • Niroomand-Rad, A.1    Blackwell, C.R.2    Coursey, B.M.3
  • 8
    • 1542476788 scopus 로고    scopus 로고
    • Radiochromic solid-state polymerization reaction
    • Irradiation of polymers, fundamentals and technological applications. Clough R.L., and Shalaby S.W. (Eds), American Chemical Society, Washington, DC
    • McLaughlin W.L., Al-Sheikhly M., Lewis D.F., Kovács A., and Wojnárovits L. Radiochromic solid-state polymerization reaction. In: Clough R.L., and Shalaby S.W. (Eds). Irradiation of polymers, fundamentals and technological applications. ACS Symposium Series 620 (1996), American Chemical Society, Washington, DC 152-166
    • (1996) ACS Symposium Series , vol.620 , pp. 152-166
    • McLaughlin, W.L.1    Al-Sheikhly, M.2    Lewis, D.F.3    Kovács, A.4    Wojnárovits, L.5
  • 9
    • 34748874051 scopus 로고    scopus 로고
    • Nuclear Associates 37-040 (HD-810) and 37-041 (MD-55) Gafchromic therapy dosimetry media instruction manual. Cardinal Health manual number 37-040-1 rev 2 8 March 2004 (http://www.cardinal.com/rms).
  • 10
    • 0035022666 scopus 로고    scopus 로고
    • Directional dependence in film dosimetry: radiographic and radiochromic film
    • Suchowerska N., Hoban P., Butson M., Davison A., and Metcalfe P. Directional dependence in film dosimetry: radiographic and radiochromic film. Phys Med Biol 46 (2001) 1391-1397
    • (2001) Phys Med Biol , vol.46 , pp. 1391-1397
    • Suchowerska, N.1    Hoban, P.2    Butson, M.3    Davison, A.4    Metcalfe, P.5
  • 11
    • 0035138715 scopus 로고    scopus 로고
    • Radiochromic film dosimetry in water phantoms
    • Butson M., Cheung T., and Yu P.K.N. Radiochromic film dosimetry in water phantoms. Phys Med Biol 46 (2001) N27-N31
    • (2001) Phys Med Biol , vol.46
    • Butson, M.1    Cheung, T.2    Yu, P.K.N.3
  • 12
    • 0031466420 scopus 로고    scopus 로고
    • GafChromic MD-55: investigated as a precision dosimeter
    • Klassen N.V., van der Zwan L., and Cygler J. GafChromic MD-55: investigated as a precision dosimeter. Med Phys 24 (1997) 1924-1934
    • (1997) Med Phys , vol.24 , pp. 1924-1934
    • Klassen, N.V.1    van der Zwan, L.2    Cygler, J.3
  • 13
    • 0030342379 scopus 로고    scopus 로고
    • Burns JE. Conversion of PDD for photon beams from one SSD to another and calculation of TAR, TMR and TPR, In: Central axis depth dose data for use in radiotherapy. Br J Radiol 1996;(Suppl 25):153-155 (Appendix B).
  • 14
    • 0031056764 scopus 로고    scopus 로고
    • Characteristics of orthovoltage X-ray therapy beams at extended SSD for applicators with end plates
    • Li X.A., Salhani D., and Ma C.-M. Characteristics of orthovoltage X-ray therapy beams at extended SSD for applicators with end plates. Phys Med Biol 42 (1997) 357-370
    • (1997) Phys Med Biol , vol.42 , pp. 357-370
    • Li, X.A.1    Salhani, D.2    Ma, C.-M.3
  • 15
    • 84912681200 scopus 로고    scopus 로고
    • Joint working party of the British institute of radiology and the institute of physics and engineering in medicine. Central axis depth dose data for use in radiotherapy
    • Aird E.G.A., Burns J.E., Day M.J., et al. Joint working party of the British institute of radiology and the institute of physics and engineering in medicine. Central axis depth dose data for use in radiotherapy. Br J Radiol Suppl 25 (1996) 1-24
    • (1996) Br J Radiol , Issue.SUPPL. 25 , pp. 1-24
    • Aird, E.G.A.1    Burns, J.E.2    Day, M.J.3
  • 16
    • 34748914457 scopus 로고    scopus 로고
    • Rogers DWO, Walters B, Kawrakow I. BEAMnrc users manual, NRC Report PIRS 509(a).
  • 17
    • 34748821985 scopus 로고    scopus 로고
    • Walters B, Kawrakow I, Rogers DWO. DOSXYZnrc users manual, NRC Report PIRS 794.
  • 18
    • 28044452190 scopus 로고    scopus 로고
    • Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
    • Chiu-Tsao S.T., Ho Y., Shankar R., Wang L., and Harrison L.B. Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies. Med Phys 32 (2005) 3350-3354
    • (2005) Med Phys , vol.32 , pp. 3350-3354
    • Chiu-Tsao, S.T.1    Ho, Y.2    Shankar, R.3    Wang, L.4    Harrison, L.B.5
  • 19
    • 33644562920 scopus 로고    scopus 로고
    • The characteristics of ionization chambers for measurements with X-rays in the kilovoltage range
    • Ma C.-M., and Seuntjens J.P. (Eds), Medical Physics Publishing, Wisconsin
    • Aukett R.J., Harrison R.M., and Rosser K.E. The characteristics of ionization chambers for measurements with X-rays in the kilovoltage range. In: Ma C.-M., and Seuntjens J.P. (Eds). Kilovoltage X-ray beam dosimetry for radiotherapy and radiobiology (1998), Medical Physics Publishing, Wisconsin 195-213
    • (1998) Kilovoltage X-ray beam dosimetry for radiotherapy and radiobiology , pp. 195-213
    • Aukett, R.J.1    Harrison, R.M.2    Rosser, K.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.