메뉴 건너뛰기




Volumn 7, Issue 5, 2007, Pages 570-574

The risks of pedicle wall breech with larger screws after undertapping

Author keywords

Breech; Pedicle; Pullout; Screw; Tapping; Torque

Indexed keywords

ADOLESCENT; ADULT; AGE; AGED; ARTICLE; CLINICAL TRIAL; EQUIPMENT DESIGN; FEMALE; FLUOROSCOPY; HUMAN; INCIDENCE; INTERVERTEBRAL DISK DEGENERATION; INTRAOPERATIVE PERIOD; LAMINECTOMY; MAJOR CLINICAL STUDY; MALE; NERVE ROOT COMPRESSION; PEDICLE SCREW; PEROPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; REOPERATION; RISK ASSESSMENT; SEX RATIO; SPINE FUSION; SPINE RADIOGRAPHY; SURGEON; SURGICAL TECHNIQUE; TORQUE; VERTEBRAL CANAL STENOSIS;

EID: 34748818024     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2006.11.001     Document Type: Article
Times cited : (8)

References (11)
  • 1
    • 0027203876 scopus 로고
    • Pedicle screw pullout strength. Correlation with insertional torque
    • Zdeblick T.A., Kunz D.N., Cooke M.E., and McCabe R. Pedicle screw pullout strength. Correlation with insertional torque. Spine 18 (1993) 1673-1676
    • (1993) Spine , vol.18 , pp. 1673-1676
    • Zdeblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3    McCabe, R.4
  • 2
    • 0141813640 scopus 로고    scopus 로고
    • Effect of various tapping diameters on insertion of thoracic pedicle screws: a biomechanical analysis
    • Kuklo T.R., and Lehman R.A. Effect of various tapping diameters on insertion of thoracic pedicle screws: a biomechanical analysis. Spine 28 (2003) 2066-2071
    • (2003) Spine , vol.28 , pp. 2066-2071
    • Kuklo, T.R.1    Lehman, R.A.2
  • 3
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • Wittenberg R.H., Lee K.S., Shea M., White III A.A., and Hayes W.C. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 296 (1993) 278-287
    • (1993) Clin Orthop Relat Res , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3    White III, A.A.4    Hayes, W.C.5
  • 5
    • 0032437971 scopus 로고    scopus 로고
    • Fracture risk during pedicle screw insertion in osteoporotic spine
    • Hirano T., Hasegawa K., Washio T., Hara T., and Takahashi H. Fracture risk during pedicle screw insertion in osteoporotic spine. J Spinal Disord 11 (1998) 493-497
    • (1998) J Spinal Disord , vol.11 , pp. 493-497
    • Hirano, T.1    Hasegawa, K.2    Washio, T.3    Hara, T.4    Takahashi, H.5
  • 6
    • 0032532465 scopus 로고    scopus 로고
    • Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis
    • Schulze C.J., Munzinger E., and Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine 23 (1998) 2215-2220
    • (1998) Spine , vol.23 , pp. 2215-2220
    • Schulze, C.J.1    Munzinger, E.2    Weber, U.3
  • 7
    • 0003115598 scopus 로고
    • Internal fixation with pedicle screws
    • White A.H., Rothman R.H., and Ray C.D. (Eds), CV Mosby, St. Louis, MO
    • Hsu K., Zucherman J.F., White A.H., et al. Internal fixation with pedicle screws. In: White A.H., Rothman R.H., and Ray C.D. (Eds). Lumbar spine surgery: techniques and complications (1987), CV Mosby, St. Louis, MO 322-338
    • (1987) Lumbar spine surgery: techniques and complications , pp. 322-338
    • Hsu, K.1    Zucherman, J.F.2    White, A.H.3
  • 8
    • 4043106389 scopus 로고    scopus 로고
    • Probing for thoracic pedicle screw tract violation(s): is it valid?
    • Lehman R.A., Potter B.K., Kuklo T.R., et al. Probing for thoracic pedicle screw tract violation(s): is it valid?. J Spinal Disord Tech 17 (2004) 277-283
    • (2004) J Spinal Disord Tech , vol.17 , pp. 277-283
    • Lehman, R.A.1    Potter, B.K.2    Kuklo, T.R.3
  • 9
    • 0029018888 scopus 로고
    • A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation
    • Glassman S.D., Dimar J.R., Puno R.M., Johnson J.R., Shields C.B., and Linden R.D. A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation. Spine 20 (1995) 1375-1379
    • (1995) Spine , vol.20 , pp. 1375-1379
    • Glassman, S.D.1    Dimar, J.R.2    Puno, R.M.3    Johnson, J.R.4    Shields, C.B.5    Linden, R.D.6
  • 10
    • 18144414312 scopus 로고    scopus 로고
    • Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement; a case report and review of the literature
    • Acosta Jr. F.L., Thompson T.L., Campbell S., Weinstein P.R., and Ames C.P. Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement; a case report and review of the literature. Spine J 5930 (2005) 339-343
    • (2005) Spine J , vol.5930 , pp. 339-343
    • Acosta Jr., F.L.1    Thompson, T.L.2    Campbell, S.3    Weinstein, P.R.4    Ames, C.P.5
  • 11
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analyis
    • Rampersaud Y.R., Pik J.H., Salonen D., and Farooq S. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analyis. Spine 30 (2005) E183-E190
    • (2005) Spine , vol.30
    • Rampersaud, Y.R.1    Pik, J.H.2    Salonen, D.3    Farooq, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.