메뉴 건너뛰기




Volumn 18, Issue 3, 2007, Pages 122-130

Image integration in electroanatomic mapping

Author keywords

Atrial fibrillation; Catheter ablation; Imaging; Mapping; Registration

Indexed keywords

CATHETER ABLATION; COMPUTER ASSISTED TOMOGRAPHY; GEOMETRY; HEART ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; IMAGE PROCESSING; NUCLEAR MAGNETIC RESONANCE IMAGING; REAL TIME ECHOGRAPHY; REVIEW;

EID: 34748812518     PISSN: 09387412     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00399-007-0571-z     Document Type: Review
Times cited : (15)

References (30)
  • 1
    • 0242694547 scopus 로고    scopus 로고
    • Dickfeld T, Calkins H, Zviman M et al (2003) Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time. Circulation 108:2407-2413
    • (2003) Circulation , vol.108 , pp. 2407
    • Dickfeld1
  • 2
    • 9644265416 scopus 로고    scopus 로고
    • Reddy VY, Malchano ZJ, Holmvang G et al (2004) Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: feasibility in a porcine model of healed myocardial infarction. J Am Coll Cardiol 44:2202-2213
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2202
    • Reddy1
  • 3
    • 19944428236 scopus 로고    scopus 로고
    • Sra J, Krum D, Hare J et al (2005) Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system. Heart Rhythm 2:55-63
    • (2005) Heart Rhythm , vol.2 , pp. 55
    • Sra1
  • 4
    • 33645010220 scopus 로고    scopus 로고
    • Dong J, Calkins H, Solomon SB et al (2006) Integrated electroanatomic mapping with three-dimensional computed tomographic images for realtime guided ablations. Circulation 113:186-194
    • (2006) Circulation , vol.113 , pp. 186
    • Dong1
  • 5
    • 0029799879 scopus 로고    scopus 로고
    • Ben-Haim SA, Osadchy D, Schuster I, Gepstein L, Hayam G, Josephson ME (1996) Nonfluoroscopic, in vivo navigation and mapping technology. Nat Med 2:1393-1395
    • (1996) Nat Med , vol.2 , pp. 1393
    • Ben-Haim1
  • 6
    • 0029902032 scopus 로고    scopus 로고
    • Sipos EP, Tebo SA, Zinreich SJ, Long DM, Brem H (1996) In vivo accuracy testing and clinical experience with the ISG Viewing Wand. Neurosurgery 39:194-202; discussion 202-204
    • (1996) Neurosurgery , vol.39 , pp. 194
    • Sipos1
  • 7
    • 0037300193 scopus 로고    scopus 로고
    • Solomon SB, Dickfeld T, Calkins H (2003) Real-time cardiac catheter navigation on three-dimensional CT images. J Interv Card Electrophysiol 8:27-36
    • (2003) J Interv Card Electrophysiol , vol.8 , pp. 27
    • Solomon1
  • 8
    • 4644324045 scopus 로고    scopus 로고
    • Dickfeld T, Calkins H, Zviman M et al (2004) Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium. J Interv Card Electrophysiol 11:105-115
    • (2004) J Interv Card Electrophysiol , vol.11 , pp. 105
    • Dickfeld1
  • 9
    • 15944409546 scopus 로고    scopus 로고
    • Dickfeld T, Calkins H, Bradley D, Solomon SB (2005) Stereotactic catheter navigation using magnetic resonance image integration in the human heart. Heart Rhythm 2:413-415
    • (2005) Heart Rhythm , vol.2 , pp. 413
    • Dickfeld1
  • 10
    • 27744472289 scopus 로고    scopus 로고
    • Noseworthy PA, Malchano ZJ, Ahmed J, Holmvang G, Ruskin JN, Reddy VY (2005) The impact of respiration on left atrial and pulmonary venous anatomy: implications for imageguided intervention. Heart Rhythm 2:1173-1178
    • (2005) Heart Rhythm , vol.2 , pp. 1173
    • Noseworthy1
  • 11
    • 33750036653 scopus 로고    scopus 로고
    • Malchano ZJ, Neuzil P, Cury RC et al (2006) Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:1221-1229
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1221
    • Malchano1
  • 12
    • 33645975865 scopus 로고    scopus 로고
    • Dong J, Dickfeld T, Dalal D et al (2006) Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:459-466
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 459
    • Dong1
  • 13
    • 1642576079 scopus 로고    scopus 로고
    • Saad EB, Marrouche NF, Saad CP et al (2003) Pulmonary vein stenosis after catheter ablation of atrial fibrillation: emergence of a new clinical syndrome. Ann Intern Med 138:634-638
    • (2003) Ann Intern Med , vol.138 , pp. 634
    • Saad1
  • 14
    • 0032746876 scopus 로고    scopus 로고
    • Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH (1999) Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 10:1525-1533
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 1525
    • Ho1
  • 15
    • 0037461101 scopus 로고    scopus 로고
    • Kato R, Lickfett L, Meininger G et al (2003) Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging. Circulation 107:2004-2010
    • (2003) Circulation , vol.107 , pp. 2004
    • Kato1
  • 16
    • 2942519274 scopus 로고    scopus 로고
    • Pappone C, Oral H, Santinelli V et al (2004) Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation. Circulation 109:2724-2726
    • (2004) Circulation , vol.109 , pp. 2724
    • Pappone1
  • 17
    • 20844438328 scopus 로고    scopus 로고
    • Lemola K, Sneider M, Desjardins B et al (2004) Computed tomographic analysis of the anatomy of the left atrium and the esophagus: implications for left atrial catheter ablation. Circulation 110:3655-3660
    • (2004) Circulation , vol.110 , pp. 3655
    • Lemola1
  • 18
    • 14644442894 scopus 로고    scopus 로고
    • Kottkamp H, Piorkowski C, Tanner H et al (2005) Topographic variability of the esophageal left atrial relation influencing ablation lines in patients with atrial fibrillation. J Cardiovasc Electrophysiol 16:146-150
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 146
    • Kottkamp1
  • 19
    • 26944436282 scopus 로고    scopus 로고
    • Tops LF, Bax JJ, Zeppenfeld K et al (2005) Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. Heart Rhythm 2:1076-1081
    • (2005) Heart Rhythm , vol.2 , pp. 1076
    • Tops1
  • 20
    • 33645279547 scopus 로고    scopus 로고
    • Kistler PM, Earley MJ, Harris S et al (2006) Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:341-348
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 341
    • Kistler1
  • 21
    • 33748748786 scopus 로고    scopus 로고
    • Kistler PM, Rajappan K, Jahngir M et al (2006) The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:1093-1101
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1093
    • Kistler1
  • 22
    • 9144242390 scopus 로고    scopus 로고
    • Vasamreddy CR, Jayam V, Lickfett L et al (2004) Technique and results of pulmonary vein angiography in patients undergoing catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 15:21-26
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 21
    • Vasamreddy1
  • 23
    • 33847163187 scopus 로고    scopus 로고
    • Heist EK, Chevalier J, Holmvang G et al (2006) Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation. J Interv Card Electrophysiol 17:21-27
    • (2006) J Interv Card Electrophysiol , vol.17 , pp. 21
    • Heist1
  • 24
    • 33947198922 scopus 로고    scopus 로고
    • Martinek M, Nesser HJ, Aichinger J, Boehm G, Purerfellner H (2006) Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation-Influence of heart rhythm and radiofrequency lesions. J Interv Card Electrophysiol 17:85-92
    • (2006) J Interv Card Electrophysiol , vol.17 , pp. 85
    • Martinek1
  • 25
    • 33846990846 scopus 로고    scopus 로고
    • Fahmy TS, Mlcochova H, Wazni OM et al (2007) Intracardiac echo-guided image integration: optimizing strategies for registration. J Cardiovasc Electrophysiol 18:276-282
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 276
    • Fahmy1
  • 26
    • 34247351639 scopus 로고    scopus 로고
    • Klemm HU, Steven D, Johnsen C et al (2007) Catheter motion during atrial ablation due to the beating heart and respiration: Impact on accuracy and spatial referencing in three-dimensional mapping. Heart Rhythm 4:587-592
    • (2007) Heart Rhythm , vol.4 , pp. 587
    • Klemm1
  • 27
    • 85069300313 scopus 로고    scopus 로고
    • Impact of heart rhythm status on registration accuracy of the left atrium for catheter ablation of atrial fibrillation
    • (in press)
    • Dong J, Dalal D, Scherr D et al. Impact of heart rhythm status on registration accuracy of the left atrium for catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol (in press)
    • J Cardiovasc Electrophysiol
    • Dong, J.1    Dalal, D.2    Scherr, D.3
  • 28
    • 33745234077 scopus 로고    scopus 로고
    • Pflaumer A, Deisenhofer I, Hausleiter J, Zrenner B (2006) Mapping and ablation of atypical flutter in congenital heart disease with a novel three-dimensional mapping system (Carto Merge). Europace 8:138-139
    • (2006) Europace , vol.8 , pp. 138
    • Pflaumer1
  • 29
    • 34748836708 scopus 로고    scopus 로고
    • Dickfeld T, Lei P, Jeudy J et al (2007) Integration of three-dimensional scar maps to guide ventricular tachycardia ablation using positron emission tomography/computed tomography (PET/CT). Heart Rhythm 4:S104-105
    • (2007) Heart Rhythm , vol.4 , pp. 104
    • Dickfeld1
  • 30
    • 65849331927 scopus 로고    scopus 로고
    • Okumura Y, Johnson S, Packer D (2007) Quantitative validation of realtime, three-dimensional ultrasound image-based mapping and intervention. Heart Rhythm 4:S344
    • (2007) Heart Rhythm , vol.4 , pp. 344
    • Okumura1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.