메뉴 건너뛰기




Volumn 53, Issue 5, 2007, Pages 617-622

Classification of physiologically significant pumping states in an implantable rotary blood pump: Patient trial results

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; ECHOCARDIOGRAPHY; IMPELLERS; MEDICAL IMAGING; NONINVASIVE MEDICAL PROCEDURES; ROTARY PUMPS;

EID: 34648841059     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318147e6a9     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0029885677 scopus 로고    scopus 로고
    • Physiologic control of cardiac assist devices
    • Hall AW, Soykan O, Harken AH: Physiologic control of cardiac assist devices. Artif Organs 20: 271-275, 1996.
    • (1996) Artif Organs , vol.20 , pp. 271-275
    • Hall, A.W.1    Soykan, O.2    Harken, A.H.3
  • 5
    • 0035158794 scopus 로고    scopus 로고
    • The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function
    • Endo G, Araki K, Kojima K, Nakamura K, Matsuzaki Y, Onitsuka T: The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. Artif Organs 25: 697-702, 2001.
    • (2001) Artif Organs , vol.25 , pp. 697-702
    • Endo, G.1    Araki, K.2    Kojima, K.3    Nakamura, K.4    Matsuzaki, Y.5    Onitsuka, T.6
  • 6
    • 0033839985 scopus 로고    scopus 로고
    • Sensorless controlling method for a continuous flow left ventricular assist device
    • Oshikawa M, Araki K, Endo G, Anai H, Sato M: Sensorless controlling method for a continuous flow left ventricular assist device. Artif Organs 24: 600-605, 2000.
    • (2000) Artif Organs , vol.24 , pp. 600-605
    • Oshikawa, M.1    Araki, K.2    Endo, G.3    Anai, H.4    Sato, M.5
  • 8
    • 23044495988 scopus 로고    scopus 로고
    • Suction detection for the MicroMed DeBakey Left Ventricular Assist Device
    • Voigt O, Benkowski RJ, Morello GF: Suction detection for the MicroMed DeBakey Left Ventricular Assist Device. ASAIO J 51: 321-8, 2005.
    • (2005) ASAIO J , vol.51 , pp. 321-328
    • Voigt, O.1    Benkowski, R.J.2    Morello, G.F.3
  • 10
    • 0033014684 scopus 로고    scopus 로고
    • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow
    • Yuhki A, Hatoh E, Nogawa M, Miura M, Shimazaki Y, Takatani S: Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow. Artif Organs 23: 532-537, 1999.
    • (1999) Artif Organs , vol.23 , pp. 532-537
    • Yuhki, A.1    Hatoh, E.2    Nogawa, M.3    Miura, M.4    Shimazaki, Y.5    Takatani, S.6
  • 13
    • 33747890685 scopus 로고    scopus 로고
    • Identification and classification of physiologically significant pumping states in an implantable rotary blood pump
    • Karantonis DM, Lovell NH, Ayre PJ, Mason DG, Cloherty SL: Identification and classification of physiologically significant pumping states in an implantable rotary blood pump. Artif Organs 30: 671-679, 2006.
    • (2006) Artif Organs , vol.30 , pp. 671-679
    • Karantonis, D.M.1    Lovell, N.H.2    Ayre, P.J.3    Mason, D.G.4    Cloherty, S.L.5
  • 16
    • 0033945454 scopus 로고    scopus 로고
    • Fluid dynamic characteristics of the VentrAssist rotary blood pump
    • Tansley G, Vidakovic S, Reizes J: Fluid dynamic characteristics of the VentrAssist rotary blood pump. Artif Organs 24: 483-487, 2000.
    • (2000) Artif Organs , vol.24 , pp. 483-487
    • Tansley, G.1    Vidakovic, S.2    Reizes, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.