메뉴 건너뛰기




Volumn 22, Issue 2, 2007, Pages 127-133

RA diagnostics using laser-optical images and conventional X-rays (fused imaging)

Author keywords

Fused imaging; Optical diagnostics; Rheumatic diseases

Indexed keywords

ABSORPTION SPECTRA; INFRARED RADIATION; LASER OPTICS; LIGHT SCATTERING; MULTISPECTRAL SCANNERS; TISSUE; X RAYS;

EID: 34648834248     PISSN: 16151615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mla.2007.03.004     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 85037690891 scopus 로고    scopus 로고
    • Beuthan J, Minet O, Müller G, Prapavat V. IR-diaphanoscopy in medicine. In: Müller G, Chance B, Alfano R, Arridge S, Beuthan J, et al., editors. Medical optical tomography: functional imaging and monitoring. Bellingham: SPIE Press IS11; 1993. p. 263-82.
  • 3
    • 34648858973 scopus 로고
    • Ein optisches ps-Radar zur bildhaften Darstellung von Objektstrukturen in menschlichen Geweben
    • Fink F., Beuthan J., and Klose E. Ein optisches ps-Radar zur bildhaften Darstellung von Objektstrukturen in menschlichen Geweben. Exp Techn Phys 38 (1990) 456-463
    • (1990) Exp Techn Phys , vol.38 , pp. 456-463
    • Fink, F.1    Beuthan, J.2    Klose, E.3
  • 4
    • 0032649560 scopus 로고    scopus 로고
    • Two- and three-dimensional optical tomography of finger joints for diagnostics of rheumatoid arhritis
    • Klose A., Hielscher A.H., Hanson K.M., and Beuthan J. Two- and three-dimensional optical tomography of finger joints for diagnostics of rheumatoid arhritis. Proc SPIE 3566 (1998) 151-160
    • (1998) Proc SPIE , vol.3566 , pp. 151-160
    • Klose, A.1    Hielscher, A.H.2    Hanson, K.M.3    Beuthan, J.4
  • 5
    • 18344379125 scopus 로고    scopus 로고
    • Frühdiagnostik der chronischen Polyarthritis mit konventionellem Röntgen
    • Wasserberg S. Frühdiagnostik der chronischen Polyarthritis mit konventionellem Röntgen. Z Rheumatol 61 (2002) 110-119
    • (2002) Z Rheumatol , vol.61 , pp. 110-119
    • Wasserberg, S.1
  • 6
    • 0036229453 scopus 로고    scopus 로고
    • Bildgebung in der Rheumatologie
    • Schneider M. Bildgebung in der Rheumatologie. Z Rheumatol 61 (2002) 107-109
    • (2002) Z Rheumatol , vol.61 , pp. 107-109
    • Schneider, M.1
  • 7
    • 0025342710 scopus 로고
    • Use of the radiograph to measure the course of rheumatoid arthritis
    • Brower A.C. Use of the radiograph to measure the course of rheumatoid arthritis. Arthritis Rheum 33 (1990) 316-324
    • (1990) Arthritis Rheum , vol.33 , pp. 316-324
    • Brower, A.C.1
  • 8
    • 0023945481 scopus 로고
    • The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis
    • Arnett F.C., Edworthy S.M., Bloch D.A., et al. The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis. Arthritis Rheum 31 (1988) 315-324
    • (1988) Arthritis Rheum , vol.31 , pp. 315-324
    • Arnett, F.C.1    Edworthy, S.M.2    Bloch, D.A.3
  • 9
    • 0001905503 scopus 로고
    • Rheumatoid arthritis and the seronegative sponylarthropathies
    • Resnick D., and Niwayama G. (Eds), W B Saunders Company, Philadephia
    • Resnick D., and Niwayama G. Rheumatoid arthritis and the seronegative sponylarthropathies. In: Resnick D., and Niwayama G. (Eds). Diagnosis of bone and joint disorders (1988), W B Saunders Company, Philadephia 894-953
    • (1988) Diagnosis of bone and joint disorders , pp. 894-953
    • Resnick, D.1    Niwayama, G.2
  • 10
    • 34648847647 scopus 로고    scopus 로고
    • Backhaus M, Banzer D, Brand GA, Felsenberg D, et al. Empfehlungen zur Röntgendiagnostik der Hände und der Füße bei rheumatologischen Fragestellungen. In: "Arbeitskreis bildgebende Diagnostik in der Rheumatologie" des regionalen Rheumazentrums Berlin e.V., Dokumentation 1997.
  • 11
    • 1942436230 scopus 로고    scopus 로고
    • MRI of the wrist in early rheumatoid arthritis
    • Peterfy C.G. MRI of the wrist in early rheumatoid arthritis. Ann Rheum Dis 63 (2004) 473-477
    • (2004) Ann Rheum Dis , vol.63 , pp. 473-477
    • Peterfy, C.G.1
  • 13
    • 34648852674 scopus 로고    scopus 로고
    • Minet O, Zabarylo U, Beuthan J. Deconvolution of fluorescent images of superficial tumors in vivo. In: Proceedings of Mediterranean conference on medical and biological engineering: health in the information society, Napoli, 2004. p. 78-81.
  • 14
    • 0036098147 scopus 로고    scopus 로고
    • Assessment of proximal finger joint inflammation in patients with rheumatoid arthritis using a novel laser-based imaging technique
    • Scheel A.K., Krause A., Mesecke von Rheinbaben I., Metzger G., Rost H., Tresp V., et al. Assessment of proximal finger joint inflammation in patients with rheumatoid arthritis using a novel laser-based imaging technique. Arthritis Rheum 46 (2002) 1177-1184
    • (2002) Arthritis Rheum , vol.46 , pp. 1177-1184
    • Scheel, A.K.1    Krause, A.2    Mesecke von Rheinbaben, I.3    Metzger, G.4    Rost, H.5    Tresp, V.6
  • 15
    • 19944431454 scopus 로고    scopus 로고
    • First clinical evaluation of sagittal laser optical tomography for detection of synovitis in arthritic finger joints
    • Scheel A.K., Backhaus M., Klose A.D., Moa-Anderson B., Netz U.J., Herrmann K.G., et al. First clinical evaluation of sagittal laser optical tomography for detection of synovitis in arthritic finger joints. Ann Rheum Dis 64 (2005) 239-245
    • (2005) Ann Rheum Dis , vol.64 , pp. 239-245
    • Scheel, A.K.1    Backhaus, M.2    Klose, A.D.3    Moa-Anderson, B.4    Netz, U.J.5    Herrmann, K.G.6
  • 16
    • 0036449145 scopus 로고    scopus 로고
    • A combined PET/CT scanner: the path to true image fusion
    • Downsend D.W., and Beyer T. A combined PET/CT scanner: the path to true image fusion. Br J Radiol 75 (2002) S24-S30
    • (2002) Br J Radiol , vol.75
    • Downsend, D.W.1    Beyer, T.2
  • 17
    • 34648852670 scopus 로고    scopus 로고
    • Sind kombinierte Geräte (PET/CT, SPECT/CT) unverzichtbar für die multimodale Bildgebung
    • Pfluger T. Sind kombinierte Geräte (PET/CT, SPECT/CT) unverzichtbar für die multimodale Bildgebung. Nuklearmed 26 (2003) 245-250
    • (2003) Nuklearmed , vol.26 , pp. 245-250
    • Pfluger, T.1
  • 18
    • 2442500981 scopus 로고    scopus 로고
    • Value of integrated PET/CT for lesion localisation in cancer patients: a comparative study
    • Pelosi E., Messa C., Sironi S., Picchio M., Landoni C., et al. Value of integrated PET/CT for lesion localisation in cancer patients: a comparative study. Eur J Nucl Med Mol Imag 31 (2004) 932-939
    • (2004) Eur J Nucl Med Mol Imag , vol.31 , pp. 932-939
    • Pelosi, E.1    Messa, C.2    Sironi, S.3    Picchio, M.4    Landoni, C.5
  • 19
    • 85040094371 scopus 로고
    • Zeichenschärfe und Diagnosequalität bei Handaufnahmen einer pcP mittels ROC-Kurven
    • Brandt G.A., Schröder H., and Mischke W. Zeichenschärfe und Diagnosequalität bei Handaufnahmen einer pcP mittels ROC-Kurven. Rad Diagn 20 (1979) 496-505
    • (1979) Rad Diagn , vol.20 , pp. 496-505
    • Brandt, G.A.1    Schröder, H.2    Mischke, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.