메뉴 건너뛰기




Volumn 83, Issue 1, 2007, Pages 216-221

Development and in vivo testing of a nitinol tracheal stent

Author keywords

Animal model; Biocompatibility; Materials testing; Nitinol; Stents; Trachea

Indexed keywords

COMPRESSION TESTING; FATIGUE TESTING; HEAT TREATMENT; MATERIALS TESTING; PHYSIOLOGICAL MODELS;

EID: 34648833440     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30786     Document Type: Article
Times cited : (11)

References (21)
  • 2
    • 0037089606 scopus 로고    scopus 로고
    • Passivation of Nitinol wire for vascular implants - A demonstration of the benefits
    • O'Brien AB, Carroll WM, Kelly MJ. Passivation of Nitinol wire for vascular implants - A demonstration of the benefits. Biomaterials 2002;23:1739-1748.
    • (2002) Biomaterials , vol.23 , pp. 1739-1748
    • O'Brien, A.B.1    Carroll, W.M.2    Kelly, M.J.3
  • 3
    • 0025124330 scopus 로고
    • A dedicated tracheobronchial stent
    • Dumon JF. A dedicated tracheobronchial stent. Chest 1990;97:328-332.
    • (1990) Chest , vol.97 , pp. 328-332
    • Dumon, J.F.1
  • 4
    • 0000787596 scopus 로고
    • Silicone stents in the management of obstructive tracheobronchial lesions: Two-year experience
    • Diaz-Jimenez JP, Muñoz EF, Ballarin JIM, Kovitz KL, Presas FM. Silicone stents in the management of obstructive tracheobronchial lesions: Two-year experience. J Bronchol 1994;1:15-18.
    • (1994) J Bronchol , vol.1 , pp. 15-18
    • Diaz-Jimenez, J.P.1    Muñoz, E.F.2    Ballarin, J.I.M.3    Kovitz, K.L.4    Presas, F.M.5
  • 5
    • 0001407544 scopus 로고    scopus 로고
    • Expandable endobronchial stents
    • Beamis JF, Mathur PN, editors, New York: McGraw-Hill;
    • Bolliger CT, Mathur PN.Expandable endobronchial stents. In: Beamis JF, Mathur PN, editors. Interventional Pulmonology. New York: McGraw-Hill; 1999. pp 113-128.
    • (1999) Interventional Pulmonology , pp. 113-128
    • Bolliger, C.T.1    Mathur, P.N.2
  • 6
    • 0000222295 scopus 로고    scopus 로고
    • Tracheobronchial stents
    • Bolliger CT, Mathur PN, editors, Basel: Karger;
    • Freitag L. Tracheobronchial stents. In: Bolliger CT, Mathur PN, editors. Interventional Bronchoscopy. Basel: Karger; 2000. pp 171-186.
    • (2000) Interventional Bronchoscopy , pp. 171-186
    • Freitag, L.1
  • 10
    • 13644253156 scopus 로고    scopus 로고
    • Removal of covered self-expandable metallic airway stents in benign disorders: Indications, technique, and outcomes
    • Noppen M, Stratakos G, D'Haese J, Meysman M, Vinken W. Removal of covered self-expandable metallic airway stents in benign disorders: Indications, technique, and outcomes. Chest 2005;127:482-487.
    • (2005) Chest , vol.127 , pp. 482-487
    • Noppen, M.1    Stratakos, G.2    D'Haese, J.3    Meysman, M.4    Vinken, W.5
  • 12
    • 0033527928 scopus 로고    scopus 로고
    • Fatigue-crack propagation in Nitinol: A shape-memory and superelastic endovascular stent material
    • McKelvey AL, Ritchie RO. Fatigue-crack propagation in Nitinol: A shape-memory and superelastic endovascular stent material. J Biomed Mater Res 1999;47:301-308.
    • (1999) J Biomed Mater Res , vol.47 , pp. 301-308
    • McKelvey, A.L.1    Ritchie, R.O.2
  • 15
    • 0342656591 scopus 로고    scopus 로고
    • Pelton AR, Stöckel D, Duerig TW. Medical uses of Nitinol materials. Sci Forum 2000; 327/328:63-70. Proceedings of the International Symposium on Shape Memory Materials, Kanazawa, Japan, May 1999.
    • Pelton AR, Stöckel D, Duerig TW. Medical uses of Nitinol materials. Sci Forum 2000; 327/328:63-70. Proceedings of the International Symposium on Shape Memory Materials, Kanazawa, Japan, May 1999.
  • 16
    • 0035570621 scopus 로고    scopus 로고
    • Physicochemical and biological aspects of Nitinol as a biomaterial
    • Shabalovskaya SA. Physicochemical and biological aspects of Nitinol as a biomaterial. Int Mater Rev 2001;46:233-250.
    • (2001) Int Mater Rev , vol.46 , pp. 233-250
    • Shabalovskaya, S.A.1
  • 17
    • 33749646965 scopus 로고    scopus 로고
    • Toxicity of used orthodontic archwires assessed by three-dimensional cell culture
    • Vannet BV, Mohebbian N, Wehrbein H. Toxicity of used orthodontic archwires assessed by three-dimensional cell culture. Eur J Orthodontics 2006;28:426-432.
    • (2006) Eur J Orthodontics , vol.28 , pp. 426-432
    • Vannet, B.V.1    Mohebbian, N.2    Wehrbein, H.3
  • 20
    • 0032912385 scopus 로고    scopus 로고
    • Evaluation of a new self-expandable silicone stent in an experimental tracheal stenosis
    • Bolliger CT, Wyser C, Wu X, Hauser R, Studer W, Dalquen P, Perruchoud AP. Evaluation of a new self-expandable silicone stent in an experimental tracheal stenosis. Chest 1999;115:496-501.
    • (1999) Chest , vol.115 , pp. 496-501
    • Bolliger, C.T.1    Wyser, C.2    Wu, X.3    Hauser, R.4    Studer, W.5    Dalquen, P.6    Perruchoud, A.P.7
  • 21
    • 4243278548 scopus 로고    scopus 로고
    • Silicone airway stents
    • Beamis JF, Mathur PN, editors, New York: McGraw-Hill;
    • Colt HG.Silicone airway stents. In: Beamis JF, Mathur PN, editors. Interventional Pulmonology. New York: McGraw-Hill; 1999. pp 97-112.
    • (1999) Interventional Pulmonology , pp. 97-112
    • Colt, H.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.