메뉴 건너뛰기




Volumn 42, Issue 6-7, 2007, Pages 1021-1024

Reconstruction of doses absorbed by radiotherapy patients by means of EPR dosimetry in tooth enamel

Author keywords

Dosimetry; Enamel; EPR; Radiotherapy

Indexed keywords

DOSIMETRY; ELECTRON BEAMS; PARAMAGNETIC RESONANCE; PHOTONS; TOOTH ENAMEL;

EID: 34548799150     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.07.013     Document Type: Article
Times cited : (8)

References (8)
  • 1
    • 0001944192 scopus 로고    scopus 로고
    • Accuracy requirements and quality assurance of external beam therapy with photons and electrons
    • Brahme A., Chavaudra J., Landberg T., et al. Accuracy requirements and quality assurance of external beam therapy with photons and electrons. Acta Oncol. (Stockholm) Suppl. 1 (1998) 1-76
    • (1998) Acta Oncol. (Stockholm) , vol.SUPPL. 1 , pp. 1-76
    • Brahme, A.1    Chavaudra, J.2    Landberg, T.3
  • 2
    • 0013956540 scopus 로고
    • A general theory of cavity ionization
    • Burlin T.E. A general theory of cavity ionization. Br. J. Radiol. 39 (1966) 727-734
    • (1966) Br. J. Radiol. , vol.39 , pp. 727-734
    • Burlin, T.E.1
  • 3
    • 33749859231 scopus 로고    scopus 로고
    • Chumak, V., Ciesielski, B., Sholom, S., Schultka, K., 2006. Lessons of the 3rd international intercomparison on EPR dosimetry with teeth: similarities and differences of two successful techniques. Radiat. Prot. Dosimetry 120, 176-183.
  • 4
    • 0023908769 scopus 로고
    • The energy response of agar-alanine phantom dosimeter to gamma radiation
    • Ciesielski B., Wielopolski L., and Reinstein L.E. The energy response of agar-alanine phantom dosimeter to gamma radiation. Med. Phys. 15 3 (1988) 380-383
    • (1988) Med. Phys. , vol.15 , Issue.3 , pp. 380-383
    • Ciesielski, B.1    Wielopolski, L.2    Reinstein, L.E.3
  • 5
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • Essers M., and Mijnheer B. In vivo dosimetry during external photon beam radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 43 2 (1999) 245-259
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.43 , Issue.2 , pp. 245-259
    • Essers, M.1    Mijnheer, B.2
  • 6
    • 34548814137 scopus 로고    scopus 로고
    • Hoshi, et al., 2007. Interlaboratory comparison of tooth enamel dosimetry on Semipalatinsk region: part 1, general view. Radiat. Meas., this issue, doi:10.1016/j.radmeas.2007.05.045.
  • 7
    • 34548757522 scopus 로고    scopus 로고
    • ICRU Report 24. 1976. Determination of Absorbed Doses in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures. International Commission on Radiation Units and Measurements, Washington, DC.
  • 8
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy?
    • Mijnheer B.J., Batterman J.J., and Wambersie A. What degree of accuracy is required and can be achieved in photon and neutron therapy?. Radiother. Oncol. 8 (1987) 237-252
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Batterman, J.J.2    Wambersie, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.