1
-
-
0031114963
-
Can we avoid an epidemic of refractive 'surprises' after cataract surgery?
-
McDonnell PJ. Can we avoid an epidemic of refractive 'surprises' after cataract surgery? Arch Ophthalmol. 1997;115:542-543.
-
(1997)
Arch Ophthalmol
, vol.115
, pp. 542-543
-
-
McDonnell, P.J.1
-
2
-
-
0030809437
-
Future shock: The long-term consequences of refractive surgery
-
Pepose JS, Lim-Bon-Siong R, Mardelli P. Future shock: the long-term consequences of refractive surgery. Br J Ophthalmol. 1997;81:428-429.
-
(1997)
Br J Ophthalmol
, vol.81
, pp. 428-429
-
-
Pepose, J.S.1
Lim-Bon-Siong, R.2
Mardelli, P.3
-
3
-
-
0028875511
-
Calculation of intraocular lens power after radial keratotomy with computerized videokeratography
-
Celikkol L, Pavlopoulos G, Weinstein B, Celikkol G, Feldman ST. Calculation of intraocular lens power after radial keratotomy with computerized videokeratography. Am J Ophthalmol. 1995;120:739-750.
-
(1995)
Am J Ophthalmol
, vol.120
, pp. 739-750
-
-
Celikkol, L.1
Pavlopoulos, G.2
Weinstein, B.3
Celikkol, G.4
Feldman, S.T.5
-
4
-
-
0028267283
-
Phacoemulsification with intraocular lens implantation after excimer photorefractive keratectomy: A case report
-
Lesher MP, Schumer DJ, Hunkeler JD, Durrie DS, McKee FE. Phacoemulsification with intraocular lens implantation after excimer photorefractive keratectomy: a case report. J Cataract Refract Surg. 1994;20:265-267.
-
(1994)
J Cataract Refract Surg
, vol.20
, pp. 265-267
-
-
Lesher, M.P.1
Schumer, D.J.2
Hunkeler, J.D.3
Durrie, D.S.4
McKee, F.E.5
-
5
-
-
0030815660
-
Intraocular lens power calculation for cataract surgery after photorefractive keratectomy for high myopia
-
Kalski RS, Danjoux JP, Fraenkel GE, Lawless MA, Rogers C. Intraocular lens power calculation for cataract surgery after photorefractive keratectomy for high myopia. J Refract Surg. 1997;13:362-366.
-
(1997)
J Refract Surg
, vol.13
, pp. 362-366
-
-
Kalski, R.S.1
Danjoux, J.P.2
Fraenkel, G.E.3
Lawless, M.A.4
Rogers, C.5
-
6
-
-
84984768831
-
Errors in intraocular lens power calculation after photorefractive keratectomy
-
Morris AH, Whittaker KW, Morris RJ, Corbett MC. Errors in intraocular lens power calculation after photorefractive keratectomy. Eye. 1998;12:327-328.
-
(1998)
Eye
, vol.12
, pp. 327-328
-
-
Morris, A.H.1
Whittaker, K.W.2
Morris, R.J.3
Corbett, M.C.4
-
7
-
-
0033955116
-
Refractive error in cataract surgery after previous refractive surgery
-
Gimbel H, Sun R, Kaye GB. Refractive error in cataract surgery after previous refractive surgery. J Cataract Refract Surg. 2000;26:142-144.
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 142-144
-
-
Gimbel, H.1
Sun, R.2
Kaye, G.B.3
-
8
-
-
0035320552
-
Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis
-
Gimbel HV, Sun R. Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis. J Cataract Refract Surg. 2001;27:571-576.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 571-576
-
-
Gimbel, H.V.1
Sun, R.2
-
9
-
-
0024820917
-
Refractive complications of cataract surgery after radial keratotomy
-
Koch DD, Liu JF, Hyde LL, Rock RL, Emery JM. Refractive complications of cataract surgery after radial keratotomy. Am J Ophthalmol. 1989;108:676-682.
-
(1989)
Am J Ophthalmol
, vol.108
, pp. 676-682
-
-
Koch, D.D.1
Liu, J.F.2
Hyde, L.L.3
Rock, R.L.4
Emery, J.M.5
-
10
-
-
0030828953
-
Disparity between keratometry-style readings and corneal power within the pupil after refractive surgery for myopia
-
Maeda N, Klyce SD, Smolek MK, McDonald MB. Disparity between keratometry-style readings and corneal power within the pupil after refractive surgery for myopia. Cornea. 1997;16:517-524.
-
(1997)
Cornea
, vol.16
, pp. 517-524
-
-
Maeda, N.1
Klyce, S.D.2
Smolek, M.K.3
McDonald, M.B.4
-
11
-
-
0036205558
-
A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis
-
Hamed AM, Wang L, Misra M, Koch DD. A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. Ophthalmology. 2002;109:651-658.
-
(2002)
Ophthalmology
, vol.109
, pp. 651-658
-
-
Hamed, A.M.1
Wang, L.2
Misra, M.3
Koch, D.D.4
-
12
-
-
22644442254
-
Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis
-
Cheng AC, Lam DS. Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis. J Refract Surg. 2005;21:365-368.
-
(2005)
J Refract Surg
, vol.21
, pp. 365-368
-
-
Cheng, A.C.1
Lam, D.S.2
-
13
-
-
30444443621
-
Posterior corneal surface changes after hyperopic laser in situ keratomileusis
-
Ueda T, Nawa Y, Masuda K, Ishibashi H, Hara Y, Uozato H. Posterior corneal surface changes after hyperopic laser in situ keratomileusis. J Cataract Refract Surg. 2005;31:2084-2087.
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 2084-2087
-
-
Ueda, T.1
Nawa, Y.2
Masuda, K.3
Ishibashi, H.4
Hara, Y.5
Uozato, H.6
-
14
-
-
16344395137
-
Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery
-
Nawa Y, Masuda K, Ueda T, Hara Y, Uozato H. Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery. J Cataract Refract Surg. 2005;31:571-573.
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 571-573
-
-
Nawa, Y.1
Masuda, K.2
Ueda, T.3
Hara, Y.4
Uozato, H.5
-
16
-
-
33644918601
-
Assessing the accuracy of Orbscan II post-LASIK: Apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures
-
Cheng AC, Yuen KS, Chan WM. Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures. Clin Experiment Ophthalmol. 2006;34:94-95.
-
(2006)
Clin Experiment Ophthalmol
, vol.34
, pp. 94-95
-
-
Cheng, A.C.1
Yuen, K.S.2
Chan, W.M.3
-
17
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
18
-
-
0036303315
-
Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia
-
Odenthal MT, Eggink CA, Melles G, Pameyer JH, Geerards AJ, Beekhuis WH. Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia. Arch Ophthalmol. 2002;120:431-438.
-
(2002)
Arch Ophthalmol
, vol.120
, pp. 431-438
-
-
Odenthal, M.T.1
Eggink, C.A.2
Melles, G.3
Pameyer, J.H.4
Geerards, A.J.5
Beekhuis, W.H.6
-
20
-
-
0036828002
-
Intraocular lens power calculations after laser in situ keratomileusis
-
Randleman JB, Loupe DN, Song CD, Waring GO III, Stulting RD. Intraocular lens power calculations after laser in situ keratomileusis. Cornea. 2002;21:751-755.
-
(2002)
Cornea
, vol.21
, pp. 751-755
-
-
Randleman, J.B.1
Loupe, D.N.2
Song, C.D.3
Waring III, G.O.4
Stulting, R.D.5
-
21
-
-
0033800604
-
Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy
-
Gimbel HV, Sun R, Furlong MT, van Westenbrugge JA, Kassab J. Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy. J Cataract Refract Surg. 2000;26:1147-1151.
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1147-1151
-
-
Gimbel, H.V.1
Sun, R.2
Furlong, M.T.3
van Westenbrugge, J.A.4
Kassab, J.5
-
22
-
-
0035086297
-
Posterior corneal curvature changes after myopic laser in situ keratomileusis
-
Seitz B, Torres F, Langenbucher A, Behrens A, Suarez E. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology. 2001;108:666-672.
-
(2001)
Ophthalmology
, vol.108
, pp. 666-672
-
-
Seitz, B.1
Torres, F.2
Langenbucher, A.3
Behrens, A.4
Suarez, E.5
-
23
-
-
18644386012
-
Assessing the accuracy of Orbscan II post-LASIK: Apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures
-
Cairns G, Ormonde SE, Gray T, Hadden OB, Morris T, Ring P, McGhee CN. Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures. Clin Experiment Ophthalmol. 2005;33:147-152.
-
(2005)
Clin Experiment Ophthalmol
, vol.33
, pp. 147-152
-
-
Cairns, G.1
Ormonde, S.E.2
Gray, T.3
Hadden, O.B.4
Morris, T.5
Ring, P.6
McGhee, C.N.7
|