메뉴 건너뛰기




Volumn , Issue , 2007, Pages 23-27

Portable, chronic neural interface system design for sensory augmentation

Author keywords

[No Author keywords available]

Indexed keywords

IMPLANTS (SURGICAL); MEDICAL PROBLEMS; NEUROLOGY; RELIABILITY ANALYSIS; SECONDARY BATTERIES; SENSORY PERCEPTION; SKIN;

EID: 34548782701     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CNE.2007.369602     Document Type: Conference Paper
Times cited : (1)

References (14)
  • 1
    • 0033360081 scopus 로고    scopus 로고
    • JK Chapin, KA Moxon, RS Markowiz and MAL, Nioolelis, MAL, Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex, Nature Neuroscience 2:664-670, 1999.
    • JK Chapin, KA Moxon, RS Markowiz and MAL, Nioolelis, MAL, "Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex," Nature Neuroscience 2:664-670, 1999.
  • 2
    • 0037036102 scopus 로고    scopus 로고
    • Direct cortical control, of 3D neuroprosthetic devices
    • DM Taylor, SIH Tilley and AB Sohwartz, "Direct cortical control, of 3D neuroprosthetic devices," Science 296;1829-1832, 2002.
    • (2002) Science , vol.296 , pp. 1829-1832
    • Taylor, D.M.1    Tilley, S.I.H.2    Sohwartz, A.B.3
  • 6
    • 33746397672 scopus 로고    scopus 로고
    • Decoding sensory feedback from firing rates of afferent ensembles recorded in cat: Dorsal root ganglia in normal locomotion
    • DJ Weber, RB Stein, DG Everaert. and A Prochazka, "Decoding sensory feedback from firing rates of afferent ensembles recorded in cat: dorsal root ganglia in normal locomotion," IEEE Trans Neural Sys Rehab. Eng 14(2):240-243, 2006.
    • (2006) IEEE Trans Neural Sys Rehab. Eng , vol.14 , Issue.2 , pp. 240-243
    • Weber, D.J.1    Stein, R.B.2    Everaert, D.G.3    Prochazka, A.4
  • 7
    • 0348147669 scopus 로고    scopus 로고
    • Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
    • A Branner, RB Stein, E Fernandez, Y Aoyagi and RA Normann, "Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve,"IEEE Trans Biomed Eng 51(1):146-157, 2004.
    • (2004) IEEE Trans Biomed Eng , vol.51 , Issue.1 , pp. 146-157
    • Branner, A.1    Stein, R.B.2    Fernandez, E.3    Aoyagi, Y.4    Normann, R.A.5
  • 9
    • 2442708539 scopus 로고    scopus 로고
    • Wireless implantable microsystems: High-density electronic interfaces to the nervous system
    • KD Wise, DJ Anderson, JF Hetke, DR Kipke and K Najafi, "Wireless implantable microsystems: high-density electronic interfaces to the nervous system," Proceedings of the IEEE 92(1):76-97, 2004.
    • (2004) Proceedings of the IEEE , vol.92 , Issue.1 , pp. 76-97
    • Wise, K.D.1    Anderson, D.J.2    Hetke, J.F.3    Kipke, D.R.4    Najafi, K.5
  • 10
    • 2942677561 scopus 로고    scopus 로고
    • Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses
    • D McDonnal, GA Clark and RA Normann, "Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses," IEEE Trans Neural Sys Rehab Eng 12(2):208-215, 2004.
    • (2004) IEEE Trans Neural Sys Rehab Eng , vol.12 , Issue.2 , pp. 208-215
    • McDonnal, D.1    Clark, G.A.2    Normann, R.A.3
  • 11
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
    • PK Campbell, KE Jones, RJ Huber, KW Horch and RA Normann, "A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array," IEEE Trans Biomed Eng 38(8):758-768, 1991.
    • (1991) IEEE Trans Biomed Eng , vol.38 , Issue.8 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 12
    • 0028662508 scopus 로고
    • A three-dimensional microelectrode array for chronic neural reoording
    • AC Hoogerwerf and KD Wise, "A three-dimensional microelectrode array for chronic neural reoording," IEEE Trans Biomed Eng 41(12):1136-1146, 1994.
    • (1994) IEEE Trans Biomed Eng , vol.41 , Issue.12 , pp. 1136-1146
    • Hoogerwerf, A.C.1    Wise, K.D.2
  • 14
    • 0028414179 scopus 로고
    • A micromachined silicon sieve eleotrode for nerve regeneration applications
    • T Akin, K Najafi, RH Smoke and RM Bradley, "A micromachined silicon sieve eleotrode for nerve regeneration applications," IEEE Trans Biomed Eng 41(4):305-313, 1994.
    • (1994) IEEE Trans Biomed Eng , vol.41 , Issue.4 , pp. 305-313
    • Akin, T.1    Najafi, K.2    Smoke, R.H.3    Bradley, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.