메뉴 건너뛰기




Volumn , Issue , 2007, Pages 572-574

Fitting improvement using a new electrical circuit model for the electrode-electrolyte interface

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC IMPEDANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; ELECTROLYTES; MEDICAL APPLICATIONS;

EID: 34548758459     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CNE.2007.369737     Document Type: Conference Paper
Times cited : (27)

References (12)
  • 1
    • 0242499142 scopus 로고    scopus 로고
    • Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance
    • L. Yang, et al., "Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance," Biosensors and Bioelectronics, Vol. 19, pp. 495-502, 2003.
    • (2003) Biosensors and Bioelectronics , vol.19 , pp. 495-502
    • Yang, L.1
  • 2
    • 0032954843 scopus 로고    scopus 로고
    • Electrical stimulation of the auditory nerve: Direct current measurement in vivo
    • C. Q. Huang, et al., "Electrical stimulation of the auditory nerve: direct current measurement in vivo," IEEE Transactions on Biomedical Engineering, Vol. 46, pp. 461-469, 1999.
    • (1999) IEEE Transactions on Biomedical Engineering , vol.46 , pp. 461-469
    • Huang, C.Q.1
  • 3
    • 0042443655 scopus 로고    scopus 로고
    • An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices
    • P. Thiebaud, et al., "An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices," Biosensors and Bioelectronics, Vol. 14, pp. 61-65, 1999.
    • (1999) Biosensors and Bioelectronics , vol.14 , pp. 61-65
    • Thiebaud, P.1
  • 4
    • 0030614375 scopus 로고    scopus 로고
    • Historical evolution of circuit models for the electrode-electrolyte interface
    • L. A. Geddes, "Historical evolution of circuit models for the electrode-electrolyte interface," Annals of Biomedical Engineering, Vol. 25, pp. 1-14, 1997.
    • (1997) Annals of Biomedical Engineering , vol.25 , pp. 1-14
    • Geddes, L.A.1
  • 5
    • 0020137662 scopus 로고
    • Linear and nonlinear properties of platinum electrode polarization. Part 1: Frequency dependence at very low frequencies
    • B. Onaral, et al., "Linear and nonlinear properties of platinum electrode polarization. Part 1: Frequency dependence at very low frequencies," Medical and Biological Engineering and Computing, Vol. 20, pp. 299-306, 1982.
    • (1982) Medical and Biological Engineering and Computing , vol.20 , pp. 299-306
    • Onaral, B.1
  • 6
    • 21844466991 scopus 로고    scopus 로고
    • Impedance characterization and modeling of electrodes for biomedical applications
    • W. Franks, et al., "Impedance characterization and modeling of electrodes for biomedical applications," IEEE Transactions on Biomedical Engineering, Vol. 52, No. 7, 2005.
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.7
    • Franks, W.1
  • 7
    • 0000897545 scopus 로고
    • Introduction to the theory, design, and modeling of thin-film microelectrodes for neural interfaces
    • D.A. Stenger and T.M. McKenna, Eds. New York: Academic, Chap. 7, pp
    • G. T. A. Kovacs, "Introduction to the theory, design, and modeling of thin-film microelectrodes for neural interfaces," in Enabling Technologies for Cultured Neural Networks, D.A. Stenger and T.M. McKenna, Eds. New York: Academic, 1994, Chap. 7, pp. 121-165.
    • (1994) Enabling Technologies for Cultured Neural Networks , pp. 121-165
    • Kovacs, G.T.A.1
  • 8
    • 8344266182 scopus 로고    scopus 로고
    • Large-area microelectrode arrays for recording of Neural signals
    • K. Mathieson, et al., "Large-area microelectrode arrays for recording of Neural signals," IEEE Transactions on Nuclear Science, Vol. 51, No. 5, pp. 2027-2031, 2004.
    • (2004) IEEE Transactions on Nuclear Science , vol.51 , Issue.5 , pp. 2027-2031
    • Mathieson, K.1
  • 9
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • D. R. Merrill, et al., "Electrical stimulation of excitable tissue: design of efficacious and safe protocols," Journal of Neuroscience Methods, Vol. 141, pp. 171-198, 2005.
    • (2005) Journal of Neuroscience Methods , vol.141 , pp. 171-198
    • Merrill, D.R.1
  • 10
    • 4544272295 scopus 로고    scopus 로고
    • Simulation of microelectrode impedance changes due to cell growth
    • X. Huang, et al., "Simulation of microelectrode impedance changes due to cell growth," IEEE Sensors Journal, Vol. 4, No. 5, pp. 576-583, 2004.
    • (2004) IEEE Sensors Journal , vol.4 , Issue.5 , pp. 576-583
    • Huang, X.1
  • 11
    • 0036591479 scopus 로고    scopus 로고
    • Harmonic analysis of low-frequency bioelectrode behavior
    • A. Richardot, et al., "Harmonic analysis of low-frequency bioelectrode behavior," IEEE Transactions on Medical Imaging, Vol. 21, No. 6, pp. 604-612, 2002.
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.6 , pp. 604-612
    • Richardot, A.1
  • 12
    • 0034233563 scopus 로고    scopus 로고
    • Nonlinear transient response of electrodeelectrolyte interfaces
    • E. T. McAdams, et al., "Nonlinear transient response of electrodeelectrolyte interfaces," Medical and Biological Engineering and Computing, Vol. 38, pp. 427-432, 2000.
    • (2000) Medical and Biological Engineering and Computing , vol.38 , pp. 427-432
    • McAdams, E.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.